At maximum controller output, the temperature value must change in a given time by a specified value, otherwise there is an error in the measuring circuit.
Table 21 – TemperatureRiseMonitoringType Definition
Attribute |
Value |
|||||
BrowseName |
TemperatureRiseMonitoringType |
|||||
IsAbstract |
False |
|||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
|
Subtype of 0:BaseObjectType defined in OPC UA Part 5 |
||||||
0:HasProperty |
Variable |
SetValueActive |
0:Boolean |
0:PropertyType |
M, RW |
|
0:HasProperty |
Variable |
ErrorDetected |
0:Boolean |
0:PropertyType |
M, RO |
|
0:HasProperty |
Variable |
SupervisionTime |
0:Duration |
0:PropertyType |
O, RW |
|
0:HasComponent |
Variable |
SetValueTemperatureChange |
0:Double |
0:AnalogItemType |
O, RW |
On / Off for the TemperatureRiseMonitoring.
Result of the TemperatureRiseMonitoring.
Specification of the time within the temperature must have changed.
Specification of the set value change
Unit: °C or F