ZoneType

Represents all functionalities of a heating zone, such as temperature monitoring, control, heatup.
The representation of the ZoneType ObjectType in the address space is shown in the following table:
Name | Attribute |
---|---|
NodeId | ns=1;i=1006 |
NamespaceUri | http://opcfoundation.org/UA/PlasticsRubber/HotRunner/ |
BrowseName | ZoneType |
NodeClass | ObjectType |
IsAbstract | False |
SubtypeOf | BaseObjectType |
The references from the ZoneType ObjectType Node are shown in the following table:
Reference | NodeClass | BrowseName | DataType | TypeDefinition | ModellingRule |
---|---|---|---|---|---|
HasComponent | Variable | CommunicationProtocolType | UInt16 | MultiStateValueDiscreteType | Optional |
HasComponent | Object | Controller | ControllerType | Mandatory | |
HasComponent | Object | HeatUp | HeatUpType | Optional | |
HasProperty | Variable | HighestActiveAlarmSeverity | UInt16 | PropertyType | Mandatory |
HasProperty | Variable | Name | String | PropertyType | Optional |
HasComponent | Object | Temperature | HRDTemperatureType | Mandatory | |
HasComponent | Object | TemperatureRiseMonitoring | TemperatureRiseMonitoringType | Optional | |
HasComponent | Variable | ThermocoupleType | UInt16 | MultiStateValueDiscreteType | Optional |