20.3.5 Load

The Method Load loads a production dataset from the file system of the machine to the control of the machine. As production datasets can contain parameter settings not only for the machine itself but also for peripheral equipment (e.g. robots/handling devices), the parts of the production dataset which shall be activated can be chosen.

Signature

Load (

[in]0:StringName

[in]0:UInt16[]Components);

Table 104 – Load Method Arguments

Argument

Description

Name

Name of the production dataset that should be loaded.

Components

Indication which parts of the production dataset shall be activated.

See Table 115 for possible values

If Components is not given (array length 0) then the complete Production dataset is activated.

Table 105 – Load Method AddressSpace Definition

Attribute

Value

BrowseName

Load

References

Node Class

BrowseName

DataType

TypeDefinition

Modelling Rule

0:HasProperty

Variable

InputArguments

Argument[]

0:PropertyType

Mandatory