This Object represents information about a single calibration zone.
Table 3 – CalibrationZoneType Definition
Attribute |
Value |
||||
BrowseName |
CalibrationZoneType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:BaseObjectType defined in OPC UA Part 5 |
|||||
0:HasProperty |
Variable |
Name |
0:LocalizedText |
0:PropertyType |
M, RW |
0:HasProperty |
Variable |
Position |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
IsPresent |
0:Boolean |
0:PropertyType |
M, RO |
0:HasComponent |
Object |
VacuumPumps |
|
3:DrivesType |
O |
0:HasComponent |
Object |
WaterPumps |
|
3:DrivesType |
O |
0:HasComponent |
Object |
Vacuum |
|
3:MeasuringDeviceType |
O |
0:HasComponent |
Object |
WaterTemperature |
|
3:MeasuringDeviceType |
O |
0:HasComponent |
Object |
WaterFlow |
|
3:MeasuringDeviceType |
O |
0:HasComponent |
Object |
WaterLevel |
|
3:MeasuringDeviceType |
O |
0:HasComponent |
Object |
AirShowerPressure |
|
3:MeasuringDeviceType |
O |
0:HasComponent |
Object |
AdditionalMeasuringDevices |
|
3:MeasuringDevicesType |
O |
Name of the calibration zone.
Position of the calibration zone.
Indication if the calibration is present/used in the process
Information about the vacuum pumps in the calibration zone. The DrivesType is defined in OPC 40083.
Information about the water pumps in the calibration zone. The DrivesType is defined in OPC 40083.
Measreument of the water temperature in the calibration zone. The MeasuringDevicesType is defined in OPC 40083.
Measreument of the water flow in the calibration zone. The MeasuringDevicesType is defined in OPC 40083.
Measreument of the water level in the calibration zone. The MeasuringDevicesType is defined in OPC 40083.
Measreument of the pressure of the air shower in the calibration zone. The MeasuringDevicesType is defined in OPC 40083.
Container for any other measured values in the calibration zone.