This OPC UA ObjectType is used for the root Object representing a calibrator as part of an extrusion line. It is based on the ExtrusionDeviceType (defined in OPC 40084-1) and formally defined in Table 1.

The instance(s) of Calibrator_InterfaceType shall be located under the DeviceSet Object of the Server (see OPC UA Part 100).

NOTE: If the OPC UA server is implemented in the control of the calibrator so only one instance of Calibrator_InterfaceType will be created. But it is also possible that one OPC UA server is connected to several machine controls as one interface to the MES. In this case several instances of Calibrator_InterfaceType will be created.

image006.gif

Figure 1 – Calibrator_InterfaceType Overview

Table 1 – Calibrator_InterfaceType Definition

Attribute

Value

BrowseName

Calibrator_InterfaceType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 4:ExtrusionDeviceType (defined in OPC 40084-1)

0:HasComponent

Object

PositionZ

3:MeasuringDeviceType

O

0:HasComponent

Object

PositionsX

3:MeasuringDevicesType

O

0:HasComponent

Object

PositionsY

3:MeasuringDevicesType

O

0:HasComponent

Object

PositionsPipeSupport

3:MeasuringDevicesType

O

0:HasComponent

Object

CalibrationZones

CalibrationZonesType

M

The BrowseName of the object instance shall be "Calibrator_<Manufacturer>_<SerialNumber>"

Example: "Calibrator_battenfeld_0123456".