7.2.1.1 PresetControl Method

This Method sets the preset value of the Encoder. The security constraints defined in chapter 6.6 apply.

Signature

PresetControl (

[in] 0:Number PresetValue

);

Argument

Description

PresetValue

The desired preset value to apply.

The Method Result Codes (defined in Call Service) are defined in Table 15.

Table 17 – Possible Method Result Codes

Result Code

Description

Good

The Method execution was successful.

Bad_UserAccessDenied

The user has not the right to execute the Method.

Bad_InvalidArgument

The Server is not able to apply the preset value. The preset value may be outside the permissive value bounds.

Bad_Locked

The parent EncoderChannelType Object is locked by a different Client’s Session.

Bad_RequiresLock

The parent EncoderChannelType Object is not locked. Clients must lock the parent EncoderChannelType Object before invoking a Method.

Bad_UnexpectedError

The server is not able to execute the function because an unexpected error occurred. The Device might be temporarily unavailable or unreachable due to network failure.

The PositionOffset Variable contains the calculated offset belonging to the current preset value of the Encoder.