The IAmperometricGasDetectorSignalConditionSetType provides the interface to Amperometric Electrochemical signal specific condition variables and is formally defined in Table 85

Table 85 – IAmperometricGasDetectorSignalConditionSetType definition

Attribute

Value

BrowseName

IAmperometricGasDetectorSignalConditionSetType

IsAbstract

True

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:BaseInterfaceType defined in OPC 10000-5, i.e. inheriting the InstanceDeclarations of that Node

0:HasComponent

Variable

SensingElementTemperature

0:Float

0:AnalogUnitType

O

0:HasProperty

Variable

SensorNextCalibrationFixed

0:Float

0:PropertyType

O

0:HasProperty

Variable

SensorNextCalibrationDynamic

0:Float

0:PropertyType

O

0:HasProperty

Variable

PowerOnDurationSensor

0:Duration

0:PropertyType

O

0:HasProperty

Variable

SensingElementResidualLife

0:Float

0:PropertyType

O

0:HasProperty

Variable

RelativeGasFlowRate

0:Float

0:PropertyType

O

0:HasProperty

Variable

ConsumedSensorCapacity

0:Float

0:PropertyType

O

0:HasProperty

Variable

RangeExceedancePeakValue

0:Float

0:PropertyType

O

0:HasProperty

Variable

RangeExceedanceDuration

0: Duration

0:PropertyType

O

0:HasProperty

Variable

SensingElementResidualSensitivity

0:Float

0:PropertyType

O

Conformance Units

PA-DIM AmperometricGasDetectorSignalType

PA-DIM AmperometricGasDetectorSignalType SensorNextCalibrationFixed

PA-DIM AmperometricGasDetectorSignalType SensorNextCalibrationDynamic

PA-DIM AmperometricGasDetectorSignalType PowerOnDurationSensor

PA-DIM AmperometricGasDetectorSignalType SensingElementResidualLife

PA-DIM AmperometricGasDetectorSignalType RelativeGasFlowRate

PA-DIM AmperometricGasDetectorSignalType ConsumedSensorCapacity

PA-DIM AmperometricGasDetectorSignalType RangeExceedance

PA-DIM AmperometricGasDetectorSignalType SensingElementResidualSensitivity

SensingElementTemperature is defined by IRDI as ABP565#001 which states "temperature measured at a sensing element".

SensorNextCalibrationFixed is defined by IRDI as ABQ016#001 which states "time expressed in days that can elapse until the next calibration, calculated from the configured calibration interval".

SensorNextCalibrationDynamic is defined by IRDI as ABQ017#001 which states "time expressed in days that can elapse until the next calibration, estimated from operational or historical information".

PowerOnDurationSensor is defined by IRDI as ABQ010#001 which states "summed duration of time intervals for which the sensor was in an operating powered state".

SensingElementResidualLife is defined by IRDI as ABP584#001 which states "degradation of a sensing element expressed as a value between 1 (good) and 0 (bad)".

RelativeGasFlowRate is defined by IRDI as ABQ011#001 which states "flow rate of gas expressed as a value between 100 (good) and 0 (bad)".

ConsumedSensorCapacity is defined by IRDI as ABQ018#001 which states "accumulated gas dosage expressed in concentration multiplied by time of exposure".

RangeExceedancePeakValue is defined by IRDI as ABQ019#001 which states "extrapolated maximum gas concentration upon overload".

RangeExceedanceDuration is defined by IRDI as ABQ020#001 which states "accumulated duration of measurement time in overload condition".

SensingElementResidualSensitivity is defined by IRDI as ABQ040#001 which states "degradation of a sensing element expressed as a value between 1 (good) and 0 (bad) calculated during its calibration".

The components of IAmperometricGasDetectorSignalConditionSetType have additional references which are defined in Table 86.

Table 86 – IAmperometricGasDetectorSignalConditionSetType additional References

SourceBrowsePath

Reference Type

Is Forward

TargetBrowsePath

SensingElementTemperature

0:HasDictionaryEntry

True

3:0112/2///61987#ABP565#001

SensorNextCalibrationFixed

0:HasDictionaryEntry

True

3:0112/2///61987#ABQ016#001

SensorNextCalibrationDynamic

0:HasDictionaryEntry

True

3:0112/2///61987#ABQ017#001

PowerOnDurationSensor

0:HasDictionaryEntry

True

3:0112/2///61987#ABQ010#001

SensingElementResidualLife

0:HasDictionaryEntry

True

3:0112/2///61987#ABP584#001

RelativeGasFlowRate

0:HasDictionaryEntry

True

3:0112/2///61987#ABQ011#001

ConsumedSensorCapacity

0:HasDictionaryEntry

True

3:0112/2///61987#ABQ018#001

RangeExceedancePeakValue

0:HasDictionaryEntry

True

3:0112/2///61987#ABQ019#001

RangeExceedanceDuration

0:HasDictionaryEntry

True

3:0112/2///61987#ABQ020#001

SensingElementResidualSensitivity

0:HasDictionaryEntry

True

3:0112/2///61987#ABQ040#001

The child Nodes of the IAmperometricGasDetectorSignalConditionSetType have additional Attribute values defined in Table 87.

Table 87 IAmperometricGasDetectorSignalConditionSetType Attribute values for child Nodes

BrowsePath

Value Attribute

SensingElementTemperature

0

SensorNextCalibrationFixed

0

SensorNextCalibrationDynamic

0

PowerOnDurationSensor

0

SensingElementResidualLife

1

RelativeGasFlowRate

0

ConsumedSensorCapacity

0

RangeExceedancePeakValue

0

RangeExceedanceDuration

0

SensingElementResidualSensitivity

1