The IAmperometricSignalConditionSetType provides the interface to amperometric measurement signal specific condition variables and is formally defined in Table 82.
Table 82 – IAmperometricSignalConditionSetType definition
|
Attribute |
Value |
||||
|
BrowseName |
IAmperometricSignalConditionSetType |
||||
|
IsAbstract |
True |
||||
|
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
|
Subtype of 0:BaseInterfaceType defined in OPC 10000-5, i.e. inheriting the InstanceDeclarations of that Node |
|||||
|
0:HasComponent |
Variable |
SensingElementTemperature |
0:Float |
0:AnalogUnitType |
O |
|
0:HasComponent |
Variable |
SensorNextCalibration |
0:UInt32 |
0:AnalogUnitType |
O |
|
0:HasProperty |
Variable |
SensorCleaningsCounter |
0:UInt32 |
0:PropertyType |
O |
|
0:HasProperty |
Variable |
SensorSterilisationsCounter |
0:UInt32 |
0:PropertyType |
O |
|
Conformance Units |
|||||
|
PA-DIM AmperometricSignalType |
|||||
|
PA-DIM AmperometricSignalType SensorNextCalibration |
|||||
|
PA-DIM AmperometricSignalType SensorCleaningsCounter |
|||||
|
PA-DIM AmperometricSignalType SensorSterilisationsCounter |
|||||
SensingElementTemperature is defined by IRDI as ABP565#001 which states “temperature measured at a sensing element”.
SensorNextCalibration is defined by IRDI as ABP566#001 which states “time that can elapse until the next calibration, calculated from the configured calibration interval or estimated by the device”.
SensorCleaningsCounter is defined by IRDI as ABP546#001 which states “number of times a sensor has been cleaned in place”.
SensorSterilisationsCounter is defined by IRDI as ABP547#001 which states “number of times a sensor has been sterilized in place”.
The components of IAmperometricSignalConditionSetType have additional references which are defined in Table 83.
Table 83 – IAmperometricSignalConditionSetType additional References
|
SourceBrowsePath |
Reference Type |
Is Forward |
TargetBrowsePath |
||
|
SensingElementTemperature |
0:HasDictionaryEntry |
True |
|||
|
0:HasDictionaryEntry |
True |
|||
|
SensorNextCalibration |
0:HasDictionaryEntry |
True |
|||
|
0:HasDictionaryEntry |
True |
|||
|
SensorCleaningsCounter |
0:HasDictionaryEntry |
True |
|||
|
SensorSterilisationsCounter |
0:HasDictionaryEntry |
True |
The child Nodes of the IAmperometricSignalConditionSetType have additional Attribute values defined in Table 84.
Table 84 – IAmperometricSignalConditionSetType Attribute values for child Nodes
|
BrowsePath |
Value Attribute |
||
|
SensingElementTemperature |
0.0 |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/cdd/IEC62720UnitId: 705741427 DisplayName: °C Description: degree Celsius |
||
|
SensorNextCalibration |
0 |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/cdd/IEC62720UnitId: 705745431DisplayName: dDescription: day |
||
|
SensorCleaningsCounter |
0 |
||
|
SensorSterilisationsCounter |
0 |