The FtnirOrFtirSignalType provides ObjectType to add FT NIR or FT IR specific variables. It is formally defined in Table 213.

Table 213 – FtnirOrFtirSignalType definition

Attribute

Value

BrowseName

FtnirOrFtirSignalType

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of AnalyticalSignalType defined in 7.27, i.e. inheriting the InstanceDeclarations of that Node

0:HasComponent

Object

<SignalCalibrationIdentifier>

0:BaseObjectType

OP

0:HasComponent

Object

SignalConditionSet

0:BaseObjectType

O

Conformance Units

PA-DIM FtnirOrFtirSignalType

PA-DIM FtnirOrFtirSignalType TransmissionRatio

PA-DIM FtnirOrFtirSignalType MahalanobisDistance

PA-DIM FtnirOrFtirSignalType SpectralResidual

PA-DIM FtnirOrFtirSignalType ElectronicsReadNoise

PA-DIM FtnirOrFtirSignalType LaserResidualLife

<SignalCalibrationIdentifier> is a container object for the calibration parameters of the signal. It is inherited from AnalogSignalType. Since it is a placeholder, an instance of FtnirOrFtirSignalType can have several calibration objects.

SignalConditionSet is a container object for the condition parameters of the signal. It is inherited from AnalogSignalType and has an additional interface reference to IFtnirOrFtirSignalConditionSetType to add FtnirOrFtirSignalType signal specific condition variables.

The components of FtnirOrFtirSignalType have additional references which are defined in Table 214

Table 214 – FtnirOrFtirSignalType additional References

SourceBrowsePath

Reference Type

Is Forward

TargetBrowsePath

SignalConditionSet

0:HasInterface

True

IFtnirOrFtirSignalConditionSetType

SignalConditionSet

SensingElementTemperature

0:EngineeringUnits

0:HasDictionaryEntry

True

3:0112/2///61987#ABA968#004

The components of FtnirOrFtirSignalType have additional subcomponents which are defined in Table 215.

Table 215 – FtnirOrFtirSignalType Additional Subcomponents

BrowsePath

References

NodeClass

BrowseName

DataType

TypeDefinition

Others

Applied from IFtnirOrFtirSignalConditionSetType

SignalConditionSet

0:HasComponent

Variable

TransmissionRatio

0:Float

0:DataItemType

O

SignalConditionSet

0:HasComponent

Variable

SensingElementTemperature

0:Float

0:AnalogUnitType

O

SignalConditionSet

0:HasProperty

Variable

MahalanobisDistance

0:Float

0:PropertyType

O

SignalConditionSet

0:HasProperty

Variable

SpectralResidual

0:Float

0:PropertyType

O

SignalConditionSet

0:HasProperty

Variable

ElectronicsReadNoise

0:Float

0:PropertyType

O

SignalConditionSet

0:HasProperty

Variable

LaserResidualLife

0:Float

0:PropertyType

O

The child Nodes of the FtnirOrFtirSignalType have additional Attribute values defined in Table 216.

Table 216 – FtnirOrFtirSignalType Attribute values for child Nodes

BrowsePath

Value Attribute

SignalConditionSet

TransmissionRatio

0.0

SignalConditionSet

SensingElementTemperature

0.0

SignalConditionSet

SensingElementTemperature

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/cdd/IEC62720UnitId: 705741427 DisplayName: °CDescription: degree Celsius

SignalConditionSet

MahalanobisDistance

0.0

SignalConditionSet

SpectralResidual

0.0

SignalConditionSet

ElectronicsReadNoise

0.0

SignalConditionSet

LaserResidualLife

1.0