Table 35 defines the namespace metadata for this document. The Object is used to provide version information for the namespace and an indication about static Nodes. Static Nodes are identical for all Attributes in all Servers, including the Value Attribute. See OPC 10000-5 for more details.

The information is provided as Object of type NamespaceMetadataType. This Object is a component of the Namespaces Object that is part of the Server Object. The NamespaceMetadataType ObjectType and its Properties are defined in OPC 10000-5.

The version information is also provided as part of the ModelTableEntry in the UANodeSet XML file. The UANodeSet XML schema is defined in OPC 10000-6.

Table 35 – NamespaceMetadata Object for this Document

Attribute

Value

BrowseName

http://opcfoundation.org/UA/Machinery/

Property

DataType

Value

NamespaceUri

String

http://opcfoundation.org/UA/Machinery/

NamespaceVersion

String

1.01.0

NamespacePublicationDate

DateTime

2021-02-25

IsNamespaceSubset

Boolean

False

StaticNodeIdTypes

IdType []

Numeric

StaticNumericNodeIdRange

NumericRange []

Null

StaticStringNodeIdPattern

String

Null

Namespaces are used by OPC UA to create unique identifiers across different naming authorities. The Attributes NodeId and BrowseName are identifiers. A Node in the UA AddressSpace is unambiguously identified using a NodeId. Unlike NodeIds, the BrowseName cannot be used to unambiguously identify a Node. Different Nodes may have the same BrowseName. They are used to build a browse path between two Nodes or to define a standard Property.

Servers may often choose to use the same namespace for the NodeId and the BrowseName. However, if they want to provide a standard Property, its BrowseName shall have the namespace of the standards body although the namespace of the NodeId reflects something else, for example the EngineeringUnits Property. All NodeIds of Nodes not defined in this document shall not use the standard namespaces.

Table 36 provides a list of mandatory and optional namespaces used in an OPC UA for Machinery OPC UA Server.

Table 36 – Namespaces used in an OPC UA for Machinery Server

NamespaceURI

Description

Use

http://opcfoundation.org/UA/

Namespace for NodeIds and BrowseNames defined in the OPC UA specification. This namespace shall have namespace index 0.

Mandatory

Local Server URI

Namespace for nodes defined in the local server. This namespace shall have namespace index 1.

Mandatory

http://opcfoundation.org/UA/DI/

Namespace for NodeIds and BrowseNames defined in OPC 10000-100. The namespace index is Server specific.

Mandatory

http://opcfoundation.org/UA/Machinery/

Namespace for NodeIds and BrowseNames defined in this document. The namespace index is Server specific.

Mandatory

Vendor specific types

A Server may provide vendor-specific types like types derived from ObjectTypes defined in this document in a vendor-specific namespace.

Optional

Vendor specific instances

A Server provides vendor-specific instances of the standard types or vendor-specific instances of vendor-specific types in a vendor-specific namespace.

It is recommended to separate vendor specific types and vendor specific instances into two or more namespaces.

Mandatory

Table 37 provides a list of namespaces and their index used for BrowseNames in this document. The default namespace of this document is not listed since all BrowseNames without prefix use this default namespace.

Table 37 – Namespaces used in this Document

NamespaceURI

Namespace Index

Example

http://opcfoundation.org/UA/

0

0:EngineeringUnits

http://opcfoundation.org/UA/DI/

2