6.9.9 ResetTotalFlow Method

ResetTotalFlow Method is used to reset the TotalFlow counter.

Signature:

ResetTotalFlow (

[in] 0:Float Initial);

Table 69 – ResetTotalFlow Method Arguments

Argument

Description

Initial

The value to initialize the TotalFlow to

Method result codes are defined as part of the Call Service (see OPC 10000-4). They are described in Table 124 for ease of reference.

Comments

Table 68 specifies the AddressSpace representation for the ResetTotalFlow Method.

Table 70 – ResetTotalFlow Method AddressSpace Definition

Attribute

Value

BrowseName

ResetTotalFlow

References

Node Class

BrowseName

DataType

TypeDefinition

Other

0:HasProperty

Variable

0:InputArguments

0:Argument[]

0:PropertyType

M

ConformanceUnits

MDIS CIMV TotalFlow