14.3.3.12 MDIS Choke Model Client Facet

Table 163 defines a Facet that describes the base characteristics for an OPC UA Client using the MDISChokeObjectType model.

Table 163 – MDIS Choke Model Client Facet

Group

Conformance Unit / Profile Title

Optional

MDIS Base

MDIS Client Base Fault

False

MDIS Base

MDIS Client Base FaultCode

True

MDIS Base

MDIS Client Base Warning

True

MDIS Base

MDIS Client Base WarningCode

True

MDIS Base

MDIS Client Base Enabled

True

MDIS Base

MDIS Client Base TagId

True

MDIS Choke

MDIS Choke Client Base

False

MDIS Choke

MDIS Choke Client DefeatableCloseInterlock

True

MDIS Choke

MDIS Choke Client DefeatableOpenInterlock

True

MDIS Choke

MDIS Choke Client NonDefeatableCloseInterlock

True

MDIS Choke

MDIS Choke Client NonDefeatableOpenInterlock

True

MDIS Choke

MDIS Choke Client Step duration

True

MDIS Choke

MDIS Choke Client Total Steps

True

MDIS Choke

MDIS Choke Client Step method

True

MDIS Choke

MDIS Choke Client CommandRejected

True