OPC Foundation
  • Documents
  • NodeSets
  • Search
6.5 DispFlag

The enumeration DispFlag is used to determine when to display messages to the machine operator. It is formally defined in Table 12.

Table 12 – DispFlag Items

Name

Value

Description

MachStart

0

To be displayed when the machine is started. Machine start is defined as switching on the main power supply or power generation.

FileLoad

1

To be displayed as soon as the file is loaded (activated) in the machine’s automation system (applicable especially to plan files originating from the mine!).

Its representation in the AddressSpace is defined in Table 13.

Table 13 – DispFlag Definition

Attribute

Value

BrowseName

DispFlag

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of the 0:Enumeration type defined in OPC 10000-5

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

Conformance Units

IREDES Component