This structure contains the Calibration information. It is used as an input argument in SetCalibration method.
Note: The input data sent in SetCalibration shall be updated in the respective parameters of the asset under Maintenance/Calibration.
The structure is defined in Table 217.
Table 217 – CalibrationDataType Structure
Name |
Type |
Description |
Optional |
CalibrationDataType |
structure |
Subtype of the 0:Structure defined in OPC 10000-5. |
|
LastCalibration |
0:UtcTime |
It is the date when the last calibration took place. Note: It can have the initial operation date for a new asset if it is not available. |
False |
CalibrationPlace |
0:String |
It is the location where the last calibration took place. |
True |
NextCalibration
|
0:UtcTime |
It is the date of the next planned calibration. |
True |
CalibrationValue |
0:Double |
It is the actual measured value of the calibration. |
True |
SensorScale |
0:Double |
It is the nominal scale of the sensor. It corresponds also with the measurement range of the sensor. |
True |
CertificateUri |
0:UriString |
It contains the URI of a certificate of the calibration target in case the calibration target is certified and the information available. Otherwise, the Variable should be omitted. The String shall be a URI as defined by RFC 3986. Example: MCE test document. |
True |
EngineeringUnits |
0:EUInformation |
It defines the engineering unit of the value. |
True |
Its representation in the AddressSpace is defined in Table 218.
Table 218 – CalibrationDataType Definition
Attribute |
Value |
||||
BrowseName |
CalibrationDataType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 0:Structure defined in OPC 10000-5. |
|||||
Conformance Units |
|||||
IJT Joining System Base |
|||||
|