This Method starts the transition into an Energy Saving Mode.

Signature

StartPause (

[in] 0:Duration PauseTime

[out] 0:Byte ModeID

[out] 0:Duration CurrentTimeToDestination

[out] 0:Duration RegularTimeToOperate

[out] 0:Duration TimeMinLengthOfStay

[out] 0:Byte ReturnCode

);

Argument

Description

PauseTime

Requested pause time.

ModeID

ID of the destination Energy Saving Mode if successful, otherwise 0.

CurrentTimeToDestination

Time needed to reach the Energy Saving Mode if successful, otherwise 0.

RegularTimeToOperate

Time needed to reach “Ready to operate” again if the destination Energy Saving Mode will be regularly terminated if successful, otherwise 0.

TimeMinLengthOfStay

Time of minimum stay in the destination Energy Saving Mode if successful, otherwise 0.

ReturnCode

Return code.

The Method Result Codes (defined in Call Service) are defined in Table 33.

ReturnCodes are defined in Table 34.