This Method starts the transition into the special WOL mode.

Signature

SwitchOffWOL (

[out] 0:Byte ModeID

[out] 0:Duration CurrentTimeToDestination

[out] 0:Duration RegularTimeToOperate

[out] 0:Duration TimeMinLengthOfStay

[out] 0:Byte ReturnCode

);

Argument

Description

ModeID

ID of the “Sleep Mode WOL” (0xFE) if successful, otherwise 0.

CurrentTimeToDestination

Time needed to reach the Energy Saving Mode if successful, otherwise 0.

RegularTimeToOperate

Time needed to reach “Ready to operate” again if the Wake-on-LAN sleep mode will be regularly terminated if successful, otherwise 0.

TimeMinLengthOfStay

Time of minimum stay in the Wake-on-LAN sleep mode if successful, otherwise 0.

ReturnCode

Return code.

The Method Result Codes (defined in Call Service) are defined in Table 33.

ReturnCodes are defined in Table 34.