This chapter defines the corresponding Conformance Units for the OPC UA Information Model for Energy Consumption Management.
Table 62 – Conformance Units for Energy Consumption Management
Category |
Title |
Description |
Server |
ECM Standby Management |
Supports the Standby Management functionality defined by EnergyStandbyManagementType. The Server is configurable to support at least on instance of EnergyStandbyManagementType. The ObjectTypes EnergyStandbyManagementType, EnergySavingModesContainerType, EnergySavingModeStatusType, and EnergySavingModeType are supported. The DataTypes StandbyModeTransitionDataType and EnergyStateInformationDataType are supported. |
Server |
ECM Standby Management Control |
Supports the Standby Management functionality defined by EnergyStandbyManagementType. The Methods StartPause, EndPause, PauseTime are supported in at least one instance of EnergyStandbyManagementType. |
Server |
ECM Energy Measurement |
Supports the Energy Measurement functionality defined by EnergyMeasurementType. The Server is configurable to support at least on instance of EnergyMeasurementType. The ObjectTypes EnergyMeasurementType and AccuracyDomainType are supported. The VariableType EnergyMeasurementValueType is supported. The DataTypes MeasurementPeriodEnum and MeasurementPeriodDataType are supported. |
Server |
ECM Accuracy Domain Percent full scale |
The instance ACCURACY_DOMAIN_PERCENT_FULL_SCALE is supported. |
Server |
ECM Accuracy Domain Percent actual reading |
The instance ACCURACY_DOMAIN_PERCENT_ACTUAL_READING is supported. |
Server |
ECM Accuracy Domain IEC |
The instance ACCURACY_DOMAIN_IEC is supported. |
Server |
ECM Accuracy Domain EN |
The instance ACCURACY_DOMAIN_EN is supported. |
Server |
ECM Sleep Mode WOL |
Supports the Sleep Mode WOL functionality defined by EnergyDevicePowerOffType. The Server is configurable to support at least on instance of EnergyDevicePowerOffType. The ObjectType EnergyDevicePowerOffType is supported. |
Server |
ECM Energy Management Support |
Supports at least one of the Conformance Units: ECM Standby Management, ECM Energy Measurement or ECM Sleep Mode WOL. |
Server |
ECM Energy Measurement Common DataTypes |
Supports the DataTypes AcPeDataType and AcPpDataType. |
Server |
ECM EnergyProfile E0 |
IEnergyProfileE0 Interface is supported by at least one EnergyMeasurementType Object instance. |
Server |
ECM EnergyProfile E1 |
IEnergyProfileE1 Interface is supported by at least one EnergyMeasurementType Object instance. |
Server |
ECM EnergyProfile E2 |
IEnergyProfileE2 Interface is supported by at least one EnergyMeasurementType Object instance. |
Server |
ECM EnergyProfile E3 |
IEnergyProfileE3 Interface is supported by at least one EnergyMeasurementType Object instance. |
Server |
ECM EnergyProfile D0 |
IEnergyProfileD0 Interface is supported by at least one EnergyMeasurementType Object instance. |
Server |
ECM EnergyProfile D1 |
IEnergyProfileD1 Interface is supported by at least one EnergyMeasurementType Object instance. |
Table 63 lists all Profiles defined in this document and defines their URIs.
Table 63 – Profile URIs for Energy Consumption Management
Profile |
URI |
ECM Energy Management Server Profile |
http://opcfoundation.org/UA-Profile/ECM/Server/EnergyManagement |
ECM Energy Management Control Server Profile |
http://opcfoundation.org/UA-Profile/ECM/Server/EnergyManagementControl |
ECM Energy Controller Server Facet |
http://opcfoundation.org/UA-Profile/ECM/Server/EnergyController |
The following sections specify the Facets available for Servers that implement the Energy Consumption Management companion specification. Each section defines and describes a Facet or Profile.
This profile defines support for base energy management functionality.
Table 64 – ECM Energy Management Server Profile
Group |
Conformance Unit / Profile Title |
M / O |
ECM |
ECM Standby Management |
O |
ECM |
ECM Energy Measurement |
O |
ECM |
ECM Sleep Mode WOL |
O |
ECM |
ECM EnergyProfile E0 |
O |
ECM |
ECM EnergyProfile E1 |
O |
ECM |
ECM EnergyProfile E2 |
O |
ECM |
ECM EnergyProfile E3 |
O |
ECM |
ECM EnergyProfile D0 |
O |
ECM |
ECM EnergyProfile D1 |
O |
ECM |
ECM Energy Measurement Common DataTypes |
O |
ECM |
ECM Energy Management Support |
M |
ECM |
ECM Accuracy Domain Percent full scale |
O |
ECM |
ECM Accuracy Domain Percent actual reading |
O |
ECM |
ECM Accuracy Domain IEC |
O |
ECM |
ECM Accuracy Domain EN |
O |
Profile |
0:Nano Embedded Device 2017 Server Profilehttp://opcfoundation.org/UA-Profile/Server/NanoEmbeddedDevice2017 |
|
Profile |
0:Data Access Server Facethttp://opcfoundation.org/UA-Profile/Server/DataAccess |
|
Profile |
0:ComplexType 2017 Server Facethttp://opcfoundation.org/UA-Profile/Server/ComplexTypes2017 |
|
This profile defines support for base for control of standby functionality.
Table 65 – ECM Energy Management Control Server Profile
Group |
Conformance Unit / Profile Title |
M / O |
Profile |
ECM Energy Controller Server Facet |
|
Profile |
ECM Energy Management Server Profile |
|
Profile |
0:Embedded 2017 Server Profilehttp://opcfoundation.org/UA-Profile/Server/EmbeddedUA2017 |
M |
This facet defines support for base functionality for control of standby functionality.
Table 66 – ECM Energy Controller Server Facet
Group |
Conformance Unit / Profile Title |
M / O |
ECM |
ECM Standby Management Control |
M |
Profile |
3:Locking Server Facet |
|
This specification does not define any Client Facets.