A valve that permits fluid to flow in one direction only (from http://data.posccaesar.org/rdl/RDS292229).

Table 86 – CheckValveType Definition

Attribute

Value

BrowseName

CheckValveType

IsAbstract

False

References

NodeClass

BrowseName

DataType /TypeDefinition

Other

Subtype of PipingComponentType

0:HasComponent

Variable

PipingComponentNumberAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

PipingComponentNameAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

HeatTracingTypeAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

InsulationThickness

0:Double0:AnalogUnitType

O

0:HasComponent

Variable

InsulationTypeAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

LowerLimitHeatTracingTemperature

0:Double0:AnalogUnitType

O

0:HasComponent

Variable

PipingClassCodeAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

HeatTracingTypeSpecialization

HeatTracingTypeClassification0:BaseDataVariableType

O

PipingComponentNumberAssignmentClass – The piping component number of the CheckValve.

PipingComponentNameAssignmentClass – The piping component name of the CheckValve.

HeatTracingTypeAssignmentClass – The heat tracing type related to the CheckValve, represented as a string.

InsulationThickness – The insulation thickness of the CheckValve.

InsulationTypeAssignmentClass – The identification code for the insulation type related to the CheckValve. So far, DEXPI does not define restrictions for valid values.

LowerLimitHeatTracingTemperature – The temperature that a heat tracing system must ensure for the CheckValve.

PipingClassCodeAssignmentClass – The identification code of the piping class of the CheckValve. So far, DEXPI does not define restrictions for valid values.

HeatTracingTypeSpecialization – A specialization indicating the heat tracing type related to the CheckValve.