A trap that consists of a chamber into which condensed steam from steam pipes etc. is allowed to drain, and which automatically ejects it without permitting the escape of steam (from http://data.posccaesar.org/rdl/RDS5782388).

Table 175– SteamTrapType Definition

Attribute

Value

BrowseName

SteamTrapType

IsAbstract

False

References

NodeClass

BrowseName

DataType /TypeDefinition

Other

Subtype of BaseDEXPIObjectType

0:HasComponent

Variable

HeatTracingTypeAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

HeatTracingTypeSpecialization

HeatTracingTypeClassification0:BaseDataVariableType

O

0:HasComponent

Variable

InsulationThickness

0:Double0:AnalogUnitType

O

0:HasComponent

Variable

PipingComponentNameAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

InsulationTypeAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

PipingClassCodeAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

PipingComponentNumberAssignmentClass

0:String0:BaseDataVariableType

O

0:HasComponent

Variable

LowerLimitHeatTracingTemperature

0:Double0:AnalogUnitType

O

HasDEXPIRelationship

ObjectType

PipeFittingType

----

--

HeatTracingTypeAssignmentClass– The heat tracing type related to the PipeFitting, represented as a string.

HeatTracingTypeSpecialization– A specialization indicating the heat tracing type related to the PipeFitting.

InsulationThickness– The insulation thickness of the PipeFitting.

PipingComponentNameAssignmentClass– The piping component name of the PipeFitting.

InsulationTypeAssignmentClass– The identification code for the insulation type related to the PipeFitting. So far, DEXPI does not define restrictions for valid values.

PipingClassCodeAssignmentClass– The identification code of the piping class of the PipeFitting. So far, DEXPI does not define restrictions for valid values.

PipingComponentNumberAssignmentClass– The piping component number of the PipeFitting.

LowerLimitHeatTracingTemperature– The temperature that a heat tracing system must ensure for the PipeFitting.

PipeFittingType– A pipe fitting.