12.8 SamplingIntervalDiagnosticsDataType

This structure contains diagnostic information about the sampling rates currently used by the Server. Its elements are defined in Table 229.

Table 229 – SamplingIntervalDiagnosticsDataType Structure

Name

Type

Description

SamplingIntervalDiagnosticsDataType

structure

samplingInterval

Duration

The sampling interval in milliseconds.

monitoredItemCount

UInt32

The number of MonitoredItems being sampled at this sample rate.

maxMonitoredItemCount

UInt32

The maximum number of MonitoredItems being sampled at this sample rate at the same time since the server was started (restarted).

disabledMonitoredItemCount

UInt32

The number of MonitoredItems at this sample rate whose sampling is currently disabled.

Its representation in the AddressSpace is defined in Table 230.

Table 230 – SamplingIntervalDiagnosticsDataType definition

Attributes

Value

BrowseName

SamplingIntervalDiagnosticsDataType

IsAbstract

FALSE

References

NodeClass

BrowseName

DataType

TypeDefinition

ModellingRule

Subtype of the Structure DataType defined in Table 187.

Conformance Units

Base Info ServerType