Errata exists for this version of the document.
Table 22 defines the structure of the ReadProcessedDetails structure.
Table 22 – ReadProcessedDetails
| Name | Type | Description | 
| ReadProcessedDetails | Structure | Specifies the details used to perform a “processed” history read. | 
| startTime | UtcTime | Beginning of period to read. | 
| endTime | UtcTime | End of period to read. | 
| ProcessingInterval | Duration | Interval between returned Aggregate values. The value 0 indicates that there is no ProcessingInterval defined. | 
| aggregateType[] | NodeId | The NodeId of the HistoryAggregate object that indicates the list of Aggregates to be used when retrieving the processed history. SeeOPC 10000-13 for details. | 
| aggregateConfiguration | Aggregate Configuration | Aggregate configuration structure. | 
| useServerCapabilitiesDefaults | Boolean | As described in OPC 10000-4. | 
| TreatUncertainAsBad | Boolean | As described in OPC 10000-13. | 
| PercentDataBad | Byte | As described in OPC 10000-13. | 
| PercentDataGood | Byte | As described in OPC 10000-13. | 
| UseSlopedExtrapolation | Boolean | As described in OPC 10000-13. | 
SeeOPC 10000-13 for details on possible NodeId values for the aggregateType parameter.