The KitchenDeviceHAConfigType configures the logging of HACCP-relevant data.
Figure 9 shows an overview of the KitchenDeviceHAConfigType with its Properties. The type is formally defined in Table 12.
In the case of variables for which HACCP-relevant measured values are logged on the device, the corresponding variable must offer the settings relevant for the logging via an object with the name "HA Configuration". The BrowseName must have the Namespace Index 0. The KitchenDeviceHAConfigType or a type derived from it is used as the type for this Object.
Figure 9 — Overview of KitchenDeviceHAConfigType
The KitchenDeviceHAConfigType is formally defined in Table 12.
Table 12 — KitchenDeviceHAConfigType Definition
Attribute |
Value |
|||||
BrowseName |
KitchenDeviceHAConfigType |
|||||
IsAbstract |
False |
|||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
ModellingRule |
|
Subtype of the HistoricalDataConfigurationType defined in OPC 10000-11. |
||||||
HasProperty |
Variable |
HistoryDuration |
Duration |
PropertyType |
M |
|
HasProperty |
Variable |
SamplingInterval |
Duration |
PropertyType |
M |
The HistoryDuration Property represents the logging time in milliseconds for which data are stored in the device.
The SamplingInterval Property represents the sampling rate for the logging in milliseconds.