The KitchenDeviceHAConfigTypeconfigures the logging of HACCP-relevant data.
Figure 9shows an overview of the KitchenDeviceHAConfigTypewith its Properties. The type is formally defined in Table 12.
In the case of variables for which HACCP-relevant measured values are logged on the device, the corresponding variable must offer the settings relevant for the logging via an object with the name "HA Configuration". The BrowseNamemust have the Namespace Index 0. The KitchenDeviceHAConfigTypeor a type derived from it is used as the type for this Object.
Figure 9 — Overview of KitchenDeviceHAConfigType
The KitchenDeviceHAConfigTypeis formally defined in Table 12.
Table 12— KitchenDeviceHAConfigType Definition
Attribute |
Value |
|||||
BrowseName |
KitchenDeviceHAConfigType |
|||||
IsAbstract |
False |
|||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
ModellingRule |
|
Subtype of the HistoricalDataConfigurationType defined in OPC 10000-11. |
||||||
HasProperty |
Variable |
HistoryDuration |
Duration |
PropertyType |
M |
|
HasProperty |
Variable |
SamplingInterval |
Duration |
PropertyType |
M |
The HistoryDuration Propertyrepresents the logging time in milliseconds for which data are stored in the device.
The SamplingInterval Propertyrepresents the sampling rate for the logging in milliseconds.