15 Type definitions for Dishwashing Machine

15.2 DishWashingMachineProgramParameterType

15.2.3 Description of the object type

15.2.3.1 ProductGroup property 
The ProductGroup property represents the parent product group.
15.2.3.2 ProductType property 
The ProductType property represents the special product type within a product group.
The specific product model is represented by the Model property of the DeviceType.
15.2.3.3 PreTankTemperatureSetpointNo property 
Specifies the number of possible washing tank temperatures (this concerns the pre-wash zone). Value range 0 … 1; 0 means that no module exists.
15.2.3.4 PreTankTemperatureSetpoint_<No.> property 
The numbered variable PreTankTemperatureSetpoint_<No.> contains the current set temperature of a washing tank (pre-wash zone). One temperature per washing tank. This variable may be used several times (numbered consecutively), depending on the number of washing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value C.
15.2.3.5 MainTankTemperatureSetpointNo property 
Specifies the number of possible washing tank temperatures (this concerns the main washing zone). Value range 0 … 5; 0 means that no module exists.
15.2.3.6 MainTankTemperatureSetpoint_<No.> property 
The numbered variable MainTankTemperatureSetpoint_<No.> contains the current set temperature of a washing tank (main washing zone). One temperature per washing tank. This variable may be used several times (numbered consecutively), depending on the number of washing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value C.
15.2.3.7 PumpedFinalRinseTemperatureSetpointNo property 
Specifies the number of possible rinsing temperatures (circulating tank). Value range 0 … 3; 0 means that no module exists.
15.2.3.8 PumpedFinalRinseTemperatureSetpoint_<No.> property 
The numbered variable PumpedFinalRinseTemperatureSetpoint_<No.> contains the current set temperature of a rinsing tank. One temperature per rinsing tank. This variable may be used several times (numbered consecutively), depending on the number of rinsing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value C.
15.2.3.9 FinalRinseTemperatureSetpointNo property 
Specifies the number of possible fresh water rinsing temperatures. Value range 0 … 3; 0 means that no module exists.
15.2.3.10 FinalRinseTemperatureSetpoint_<No.> property 
The numbered variable FinalRinseTemperatureSetpoint_<No.> contains the current set temperature of a rinsing tank (fresh water rinsing). One temperature per rinsing tank. This variable may be used several times (numbered consecutively), depending on the number of rinsing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value C.
15.2.3.11 ActualPreTankTemperatureNo property 
Specifies the number of possible washing tank temperatures (this concerns the pre-wash zone). Value range 0 … 1; 0 means that no module exists.
15.2.3.12 ActualPreTankTemperature_<No.> property 
The numbered variable ActualPreTankTemperature_<No.> contains the current actual temperature of a washing tank (pre-wash zone). One temperature per washing tank. This variable may be used several times (numbered consecutively), depending on the number of washing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value C.
15.2.3.13 ActualMainTankTemperatureNo property 
Specifies the number of possible washing tank temperatures (this concerns the main washing zone). Value range 0 … 5; 0 means that no module exists.
15.2.3.14 ActualMainTankTemperature_<No.> property 
The numbered variable ActualMainTankTemperature_<No.> contains the current actual temperature of a washing tank (main washing zone). One temperature per washing tank. This variable may be used several times (numbered consecutively), depending on the number of washing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value C.
15.2.3.15 ActualPumpedFinalRinseTemperatureNo property 
Specifies the number of possible fresh water rinsing temperatures (circulation). Value range 0 … 3; 0 means that no module exists.
15.2.3.16 ActualPumpedFinalRinseTemperature_<No.> property 
The numbered variable ActualPumpedFinalRinseTemperature_<No.> contains the current actual temperature of a rinsing tank (circulation). One temperature per rinsing tank. This variable may be used several times (numbered consecutively), depending on the number of rinsing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value C.
15.2.3.17 ActualFinalRinseTemperatureNo property 
Specifies the number of possible rinsing temperatures (fresh water rinsing). Value range 0 … 3; 0 means that no module exists.
15.2.3.18 ActualFinalRinseTemperature_<No.> property 
The numbered variable ActualFinalRinseTemperature_<No.> contains the current actual temperature of a rinsing tank (fresh water rinsing). One temperature per rinsing tank. This variable may be used several times (numbered consecutively), depending on the number of rinsing tanks that exist.
The EngineeringUnit property of the AnalalogItemType has the value C.
15.2.3.19 HygieneSetpoint property 
A variable for the Hygiene setpoint. This variable has no unit. The evaluation depends on the hygiene process.
15.2.3.20 ActualHygieneValue property 
A variable for the actual Hygiene value. This variable has no unit. The evaluation depends on the hygiene process.
15.2.3.21 ProgramMode property 
A variable that makes the state of the machine available via the ProgramModeEnumeration.
15.2.3.22 HygieneMode property 
A variable that makes the state of the machine available via the HygieneModeEnumeration.
15.2.3.23 OperationMode property 
A variable that makes the state of the machine available via the OperationModeEnumeration.