This DataType is a structure that defines the settings for a scan execution. Its composition is formally defined in Table 53.
Table 53 – ScanSettings Structure
Name |
Type |
Description |
Optional |
ScanSettings |
Structure |
Subtype of Structure defined in OPC 10000-5. |
|
Duration |
Duration |
Duration of the scan operation in milliseconds. Duration is one of the termination conditions for the scan operation. The value 0 is infinite. The termination conditions are related to each other. If one of the conditions is fulfilled, the scan operation is stopped. |
False |
Cycles |
Int32 |
Duration of the scan operation in ‘number of scan cycles’. The parameter Cycles is one of the termination conditions for the scan operation. The value 0 is infinite. The termination conditions are related to each other. If one of the conditions is fulfilled, the scan operation is stopped. |
False |
DataAvailable |
Boolean |
If this value is set to True, the scan operation is completed as soon as scan data is available. If this value is set to False, only the other termination conditions are used. |
False |
LocationType |
LocationType Enumeration |
The requestsd type of the location information returned in the scan results. The LocationTypeEnumeration DataType is defined in 9.2.3. |
True |
Its representation in the AddressSpace is defined in Table 54.
Attribute |
Value |
|||||
BrowseName |
ScanSettings |
|||||
IsAbstract |
False |
|||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
|
Subtype of Structure defined in OPC 10000-5. |
Table 54 – ScanSettings Definition