10.1 RunInfoDataType

This structure contains the information related to a job run. The structure is defined in Table 23.

Table 23 – RunInfoDataType Structure

Name

Type

Description

Optional

RunInfoDataType

structure

Subtype of 0:Structure defined in OPC 10000-5

CurrentLayer

0:UInt32

Counter that increases after each completed layer of the job run. This counter does not give any indication about the part quality.

True

Identifier

0:String

Identifier of the job run. This identifier is used to ensure an assignment of parts and job run(s). For this reason, the identifier shall be unique.

False

State

9:ISA95StateDataType

State information on job run level. This state works additionally to the overall job status.

False

RemainingTime

0:Duration

Describes the remaining process time in seconds.

True

Its representation in the AddressSpace is defined in Table 24.

Table 24 – RunInfoDataType Definiton

Attribute

Value

BrowseName

RunInfoDataType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the 0:Structure defined in OPC 10000-5

Conformance Units

AdditiveManufacturing Job Management - Run Information

Please report errors or issues with the site to webmaster.