Annex C (normative) Event and Alarm Categories ToC Previous Next

Table C.1 contains the defined NotificationCategories which can be used for classification of the alarms or events.

Table C.1 – Defined NotificationCategories

Name ValueAsText EnumValue Description
Others OTHERS 0 Notifcation that are not related to another class
Process PROCESS 1 Notifcation that are related to the weighing or value-added process
System SYSTEM 2 Notifcation that are related to scale system, like date errors or hardware errors
Memory MEMORY 3 Notifcation that are related to the memory.
Component COMPONENT 4 Notifcation that are related a component of the scale
Communication COMMUNICATION 5 Notifcation that are related a communication system like a field bus error
WeighingBridgeModule WEIGHING_MODULE 6 Notifcation that are related to the weighingBridgeModule
Environment ENVIRONMENT 7 Notifcation that are related to the environment

Table C.2 contains the defined NotificationIds.

Table C.2 – Defined NotificationIds

NotificationId - ValueAsText NotificationId - EnumValue NotificationCategory Description
NotificationIds that are not related to a other class      
GENERAL_OTHER_FAULT 1 OTHERS A general fault that not related to an other NotificationCategory
NotificationIds releated to the Process      
GENERAL_PROCESS_FAULT 100 PROCESS A general fault that is related to the process. This fault should be used if no other fault related to the process exist..
PRODUCT_DATA_FAULT 101 PROCESS Inconsistent or incomplete product data
LABEL_FAULT 102 PROCESS General label error, limited only to the label
BAD_PACK 103 PROCESS Package sorted out
CRITICAL_EXTERNAL_FAULT 104 PROCESS Critical Alarm from external Device (like metal detector, external storage etc.)
REJECT_VERIFICATION_FAULT 105 PROCESS Item reject process not succesfull
CONTAMINATION_DETECT 106 PROCESS Machine rejects due to a detected contamination (x-ray / MD)
VISION_INSPECTION 107 PROCESS Machinine rejects due to a wrong vision of code inspection
CONSECUTIVE_REJECTS 108 PROCESS Machine stop due to consecutive rejects
EMERGENCY_STOP 109 PROCESS Emergency stop is active and not acknowledged yet
NotificationIds releated to the System      
GENERAL_SYSTEM_FAULT 200 SYSTEM A general fault that is related to the system. This fault should be used if no other fault related to the system exist
LOGIN_FAULT 201 SYSTEM Unsuccesfull login event
NotificationIds releated to the Memory      
GENERAL_MEMORY_FAULT 300 MEMORY A general fault that is related to the memory
NotificationIds releated to the Component of a scale      
GENERAL_COMPONENT_FAULT 400 COMPONENT A general fault that is related to the component of a system. This fault should be used if no other fault related to the component exist
PRINTER_FAULT 401 COMPONENT General printer fault, which prevents at least one printer from printing
FEEDER_FAULT 402 COMPONENT General Feeder error, but feeder is running yet
FEEDER_NOT_RUNNING 403 COMPONENT Special Alarm to indicate “feeder not running” state
NotificationIds releated to the Communication of a scale      
GENERAL_COMMUNICATION_FAULT 500 COMMUNICATION A general fault that is related to the communication system. This fault should be used if no other fault related to the communication exist
NotificationIds releated to the weighing module      
GENERAL_WEIGHING_MODULE_FAULT 600 WEIGHING_MODULE A general fault that is related to the weighing module This fault should be used if no other fault related to the weighing module exist
OVERLOAD_FAULT 601 WEIGHING_MODULE Scale overloaded. That means the maximum allowed measured weight value is exceeded and the Overload property of a WeightItemType is true.
OUT_OF_RANGE_FAULT 602 WEIGHING_MODULE Weight out of (approved) range, but not yet overload
UNDERLOAD_FAULT 603 WEIGHING_MODULE Scale underloaded. That means the minimum allowed measured weight value is gone below.
TARE_SETTING_FAULT 604 WEIGHING_MODULE Error during tare setting
ZERO_SETTING_FAULT 605 WEIGHING_MODULE Error during zero setting
REZERO_REQUIRED 606 WEIGHING_MODULE Load cell re-zeroing is required
NotificationIds releated to the Environment      
GENERAL_ENVIRONMENT_FAULT 700 ENVIRONMENT A general fault that is related to the environment system. This fault should be used if no other fault related to the environment exist
POWER_SUPPLY_FAULT 701 ENVIRONMENT General faulty power supply
AIR_PRESSURE_FAULT 702 ENVIRONMENT General faulty air pressure