Annex C (normative) Event and Alarm Categories

Table C.1 contains the defined NotificationCategories which can be used for classification of the alarms or events.
Table C.1 – Defined NotificationCategories
Name | ValueAsText | EnumValue | Description |
---|---|---|---|
Others | OTHERS | 0 | Notifcation that are not related to another class |
Process | PROCESS | 1 | Notifcation that are related to the weighing or value-added process |
System | SYSTEM | 2 | Notifcation that are related to scale system, like date errors or hardware errors |
Memory | MEMORY | 3 | Notifcation that are related to the memory. |
Component | COMPONENT | 4 | Notifcation that are related a component of the scale |
Communication | COMMUNICATION | 5 | Notifcation that are related a communication system like a field bus error |
WeighingBridgeModule | WEIGHING_MODULE | 6 | Notifcation that are related to the weighingBridgeModule |
Environment | ENVIRONMENT | 7 | Notifcation that are related to the environment |
Table C.2 contains the defined NotificationIds.
Table C.2 – Defined NotificationIds
NotificationId - ValueAsText | NotificationId - EnumValue | NotificationCategory | Description |
---|---|---|---|
NotificationIds that are not related to a other class | |||
GENERAL_OTHER_FAULT | 1 | OTHERS | A general fault that not related to an other NotificationCategory |
NotificationIds releated to the Process | |||
GENERAL_PROCESS_FAULT | 100 | PROCESS | A general fault that is related to the process. This fault should be used if no other fault related to the process exist.. |
PRODUCT_DATA_FAULT | 101 | PROCESS | Inconsistent or incomplete product data |
LABEL_FAULT | 102 | PROCESS | General label error, limited only to the label |
BAD_PACK | 103 | PROCESS | Package sorted out |
CRITICAL_EXTERNAL_FAULT | 104 | PROCESS | Critical Alarm from external Device (like metal detector, external storage etc.) |
REJECT_VERIFICATION_FAULT | 105 | PROCESS | Item reject process not succesfull |
CONTAMINATION_DETECT | 106 | PROCESS | Machine rejects due to a detected contamination (x-ray / MD) |
VISION_INSPECTION | 107 | PROCESS | Machinine rejects due to a wrong vision of code inspection |
CONSECUTIVE_REJECTS | 108 | PROCESS | Machine stop due to consecutive rejects |
EMERGENCY_STOP | 109 | PROCESS | Emergency stop is active and not acknowledged yet |
NotificationIds releated to the System | |||
GENERAL_SYSTEM_FAULT | 200 | SYSTEM | A general fault that is related to the system. This fault should be used if no other fault related to the system exist |
LOGIN_FAULT | 201 | SYSTEM | Unsuccesfull login event |
NotificationIds releated to the Memory |
GENERAL_MEMORY_FAULT | 300 | MEMORY | A general fault that is related to the memory |
---|---|---|---|
NotificationIds releated to the Component of a scale | |||
GENERAL_COMPONENT_FAULT | 400 | COMPONENT | A general fault that is related to the component of a system. This fault should be used if no other fault related to the component exist |
PRINTER_FAULT | 401 | COMPONENT | General printer fault, which prevents at least one printer from printing |
FEEDER_FAULT | 402 | COMPONENT | General Feeder error, but feeder is running yet |
FEEDER_NOT_RUNNING | 403 | COMPONENT | Special Alarm to indicate “feeder not running” state |
NotificationIds releated to the Communication of a scale | |||
GENERAL_COMMUNICATION_FAULT | 500 | COMMUNICATION | A general fault that is related to the communication system. This fault should be used if no other fault related to the communication exist |
NotificationIds releated to the weighing module | |||
GENERAL_WEIGHING_MODULE_FAULT | 600 | WEIGHING_MODULE | A general fault that is related to the weighing module This fault should be used if no other fault related to the weighing module exist |
OVERLOAD_FAULT | 601 | WEIGHING_MODULE | Scale overloaded. That means the maximum allowed measured weight value is exceeded and the Overload property of a WeightItemType is true. |
OUT_OF_RANGE_FAULT | 602 | WEIGHING_MODULE | Weight out of (approved) range, but not yet overload |
UNDERLOAD_FAULT | 603 | WEIGHING_MODULE | Scale underloaded. That means the minimum allowed measured weight value is gone below. |
TARE_SETTING_FAULT | 604 | WEIGHING_MODULE | Error during tare setting |
ZERO_SETTING_FAULT | 605 | WEIGHING_MODULE | Error during zero setting |
REZERO_REQUIRED | 606 | WEIGHING_MODULE | Load cell re-zeroing is required |
NotificationIds releated to the Environment | |||
GENERAL_ENVIRONMENT_FAULT | 700 | ENVIRONMENT | A general fault that is related to the environment system. This fault should be used if no other fault related to the environment exist |
POWER_SUPPLY_FAULT | 701 | ENVIRONMENT | General faulty power supply |
AIR_PRESSURE_FAULT | 702 | ENVIRONMENT | General faulty air pressure |