9 Profiles and ConformanceUnits ToC Previous Next

9.2 Profiles ToC Previous Next

9.2.2 Server Facets ToC Previous Next

9.2.2.1 Overview ToC

The following sections specify the Facets available for Servers that implement the OPC UA for Pumps and Vacuum Pumps companion specification. Each section defines and describes a Facet or Profile.

9.2.2.2 Pump Base Server Profile ToC

This Profile defines the elements for a Pump Server which supports basic functionality like the configuration of the Pump, perform various analyses, and provide machine identification.

Table 154 – Pump Base Server Profile

Group Conformance Unit / Profile Title M / O
Profile 0:Embedded 2017 UA Server Profile
http://opcfoundation.org/UA-Profile/Server/EmbeddedUA2017
M
Profile 0:Data Access Server Facet
http://opcfoundation.org/UA-Profile/Server/DataAccess
M
Profile 0:ComplexType 2017 Server Facet
http://opcfoundation.org/UA-Profile/Server/ComplexTypes2017
M
Profile 0:Aggregate Subscription Server Facet
http://opcfoundation.org/UA-Profile/Server/AggregateSubscription
M
Profile 3:Machine Identification Writable Server Facet
http://opcfoundation.org/UA-Profile/Machinery/Server/MachineIdentificationWritable
M
Pump Pump PumpType Mandatory Nodes M
Pump Base System M

9.2.2.3 Pump Advanced Server Profile ToC

This Profile defines the elements for a Pump Server which supports advanced functionality like the control of the pump, provide health and limit status in the AddressSpace and provide ports.

Table 155 – Pump Advanced Server Profile

Group Conformance Unit / Profile Title M / O
Profile 0:Address Space Notifier Server Facet
http://opcfoundation.org/UA-Profile/Server/AddressSpaceNotifier
M
Profile 0:A & C Address Space Instance Server Facet
http://opcfoundation.org/UA-Profile/Server/ACAddressSpaceInstance
M
Profile 0:A & C Exclusive Alarming Server Facet
http://opcfoundation.org/UA-Profile/Server/ACExclusiveAlarming
M
Profile 0:Base Historical Event Server Facet
http://opcfoundation.org/UA-Profile/Server/BaseHistoricalEvent
M
Profile 0:Historical Raw Data Server Facet
http://opcfoundation.org/UA-Profile/Server/HistoricalRawData
M
Profile 0:Historical Aggregate Server Facet
http://opcfoundation.org/UA-Profile/Server/AggregateHistorical
M
Profile Pump Base Server Profile
http://opcfoundation.org/UA-Profile/CAS/Server/Base
M
Pumps Historizing O
Pumps Limit Alarm Status O
Pumps PumpClass Data O
Pumps Pump Connection Port O
Pumps Pump Control O
Pumps Pump Drive Port O
Pumps Supervision Health Status O