The OutletConnectionMeasurementsType provides Variables used for measurements performed at a Pump outlet connection and is formally defined in Table 112. For the generation of events, the OutletConnectionMeasurementsType has a reference to the 0:LimitAlarmType. The InputNode Property of the Alarm shall contain the NodeId of the Component. Measurements defined in this ObjectType have an additional Subcomponent with the TypeDefinition 0:PropertyType and the BrowseName KindOfQuantity defined in Table 113. In this Variables the measurements can be matched to a physical quantity. To comply with this Companion Specification, the default values for the Property 0:EngineeringUnits and the Property KindOfQuantity provided in Table 114 should be used. The values should be sensible to the use of the application.

Table 112 – OutletConnectionMeasurementsType Definition

Attribute Value        
BrowseName OutletConnectionMeasurementsType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node.          
0: HasComponent Variable MeanVelocityAtOutlet 0:Double 0:BaseAnalogType O, RO
0:HasComponent Variable OutletTemperatureOfThePump 0:Double 0:BaseAnalogType O, RO
0:GeneratesEvent ObjectType 0:LimitAlarmType Defined in OPC 10000-9    

Table 113 – OutletConnectionMeasurementsType Additional Subcomponents

Source Path References NodeClass BrowseName DataType TypeDefinition Other
MeanVelocityAtOutlet 0:HasProperty Variable KindOfQuantity 0:String 0:PropertyType O, RO
OutletTemperatureOfThePump 0:HasProperty Variable KindOfQuantity 0:String 0:PropertyType O, RO

The InstanceDeclarations of the OutletConnectionMeasurementsType have additional Attributes defined in Table 114. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1.

Table 114 – OutletConnectionMeasurementsType Attribute values for child Nodes

BrowsePath Value Attribute Description Attribute
MeanVelocityAtOutlet   Measured rate of flow at pump outlet connection divided by the outlet area of the pump.
   MeanVelocityAtOutlet
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5067859
DisplayName: m/s
Description: metre per second
 
   MeanVelocityAtOutlet
   KindOfQuantity
“velocity” Vector quantity giving the rate of change of a position vector
OutletTemperatureOfThePump   Measured temperature acting at the outlet area of the pump.
   OutletTemperatureOfThePump
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 4932940
DisplayName: K
Description: kelvin
 
   OutletTemperatureOfThePump
   KindOfQuantity
“temperature” Quantity representing a temperature value