7 OPC UA ObjectTypes ToC Previous Next

7.48 OutletConnectionImplementationType ObjectType Definition ToC Previous Next

The OutletConnectionImplementationType extends its supertype by Pump inlet connection specific Variables and is formally defined in Table 104.

Table 104 – OutletConnectionImplementationType Definition

Attribute Value        
BrowseName OutletConnectionImplementationType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the ConnectionImplementationType defined in 7.46, i.e. inheriting the InstanceDeclarations of that Node.          
0:HasComponent Variable HeightOfTheOutletConnection 0:Double 0:BaseAnalogType O, RW
0:HasComponent Variable MeanRatedVelocityAtOutlet 0:Double 0:BaseAnalogType O, RW
0:HasComponent Variable RatedOutletPressure 0:Double 0:BaseAnalogType O, RW
0:HasComponent Variable TotalHeadAtOutletAreaOfThePump 0:Double 0:BaseAnalogType O, RW

The InstanceDeclarations of the OutletConnectionImplementationType have additional Attributes defined in Table 105. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1.

Table 105 – OutletConnectionImplementationType Attribute values for child Nodes

BrowsePath Value Attribute Description Attribute
HeightOfTheOutletConnection   Height of the center of the outlet connection of the pump.
   HeightOfTheOutletConnection
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5067858
DisplayName: m
Description: metre
 
MeanRatedVelocityAtOutlet   Rated flow at pump outlet connection divided by the inlet area of the pump.
   MeanRatedVelocityAtOutlet
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5067859
DisplayName: m/s
Description: metre per second
 
RatedOutletPressure   Outlet pressure of the pump at the guarantee point with rated flow and rated speed, as well as rated inlet pressure, for rotodynamic pumps only.
   RatedOutletPressure
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5259596
DisplayName: Pa
Description: pascal
 
TotalHeadAtOutletAreaOfThePump   Head observed at outlet area of the pump, corresponding to the sum of the height, pressure head and velocity head.
   TotalHeadAtOutletAreaOfThePump
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5067858
DisplayName: m
Description: metre
 

Previous Next