7 OPC UA ObjectTypes ToC Previous Next

7.42 OutletConnectionDesignType ObjectType Definition ToC Previous Next

The OutletConnectionDesignType extends its supertype by Pump outlet connection specific Variables and is formally defined in Table 92.

Table 92 – OutletConnectionDesignType Definition

Attribute Value        
BrowseName OutletConnectionDesignType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the ConnectionDesignType defined in 7.40, i.e. inheriting the InstanceDeclarations of that Node.          
0:HasComponent Variable MaximumAllowableOutletPressure 0:Double 0:BaseAnalogType O, RO
0:HasComponent Variable MinimumAllowableOutetPressure 0:Double 0:BaseAnalogType O, RO
0:HasComponent Variable OutletAreaOfThePump 0:Double 0:BaseAnalogType O, RO
0:HasComponent Variable ReliefValveAccumulationPressure 0:Double 0:BaseAnalogType O, RO
0:HasComponent Variable ReliefValveBackPressure 0:Double 0:BaseAnalogType O, RO
0:HasComponent Variable ReliefValveReseatPressure 0:Double 0:BaseAnalogType O, RO
0:HasComponent Variable ReliefValveSetPressure 0:Double 0:BaseAnalogType O, RO

The InstanceDeclarations of the OutletConnectionDesignType have additional Attributes defined in Table 93. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1.

Table 93 – OutletConnectionDesignType Attribute values for child Nodes

BrowsePath Value Attribute Description Attribute
MaximumAllowableOutletPressure   Highest value of outlet pressure at which the pump or component is capable of functioning on the basis of the materials used.
   MaximumAllowableOutletPressure
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5259596
DisplayName: Pa
Description: pascal
 
MinimumAllowableOutetPressure   Lowest value of outlet pressure at which the pump or component is capable of functioning on the basis of the materials used.
   MinimumAllowableOutetPressure
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5259596
DisplayName: Pa
Description: pascal
 
OutletAreaOfThePump   Free cross-sectional area of the orifice in the outlet connection of the pump.
   OutletAreaOfThePump
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5067851
DisplayName: m²
Description: square metre
 
ReliefValveAccumulationPressure   Outlet pressure at which the relief valve will pass the total pump flow.
   ReliefValveAccumulationPressure
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5259596
DisplayName: Pa
Description: pascal
 
ReliefValveBackPressure   Pressure at the outlet of the relief valve when the valve is closed.
   ReliefValveBackPressure
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5259596
DisplayName: Pa
Description: pascal
 
ReliefValveReseatPressure   Outlet pressure at which the relief valve will close after passing the total pump flow.
   ReliefValveReseatPressure
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5259596
DisplayName: Pa
Description: pascal
 
ReliefValveSetPressure   Outlet pressure at which the relief valve begins to open.
   ReliefValveSetPressure
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5259596
DisplayName: Pa
Description: pascal
 

Previous Next