10 DeviceZoneType ToC Previous Next

The DeviceZoneType represents the functional main component of a TCD and is therefore mandatory.

readme_files/image006.gif Figure 2 – DeviceZoneType Overview

Table 7 – DeviceZoneType Definition

Attribute Value        
BrowseName DeviceZoneType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseObjectType defined in OPC UA Part 5          
0:HasComponent Object Temperature   ControlledParameterType M
0:HasComponent Variable InternalMeasuringPoint 0:UInt16 0:MultiStateValueDiscreteType O, RW
0:HasComponent Variable StandbyTemperature 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable SwitchingOffTemperature 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable TemperatureLimitation 0:Double 0:AnalogItemType O, RW
0:HasComponent Variable TemperatureMainLine 0:Double 0:AnalogItemType O, RO
0:HasComponent Variable TemperatureReturnLine 0:Double 0:AnalogItemType O, RO
0:HasComponent Object TemperatureDifference   3:MonitoredParameterType O
0:HasComponent Object FlowRate   3:MonitoredParameterType O
0:HasComponent Variable PressureMainLine 0:Double 0:AnalogItemType O, RO
0:HasComponent Variable PressureReturnLine 0:Double 0:AnalogItemType O, RO
0:HasComponent Object PressureDifference   3:MonitoredParameterType O
0:HasComponent Variable ActualProcessPower 0:Double 0:AnalogItemType O, RO
0:HasComponent Variable ActualRegulationRatio 0:Double 0:AnalogItemType O, RO
0:HasComponent Variable DelayTimeAfterCooling 0:Double 0:AnalogItemType O, RW
0:HasComponent Object PumpSpeed   3:MonitoredParameterType O
0:HasComponent Variable ActualPumpSpeedRPM 0:Double 0:AnalogItemType O, RO
0:HasComponent Variable ActualPumpPower 0:Double 0:AnalogItemType O, RO
0:HasComponent Variable PumpControlMode 0:UInt16 0:MultiStateValueDiscreteType O, RW
0:HasComponent Object ExternalSensor   ExternalSensorType O
0:HasComponent Object LeakStopper   LeakStopperType O
0:HasComponent Object MouldEvacuation   MouldEvacuationType O
0:HasComponent Object MaintenanceInformation   MaintenanceInformationType O
0:HasComponent Object ExternalChannels   ExternalChannelsType O

NOTE: The MonitoredParameterType is defined in OPC 40083. If the Parameter is not only monitored but controlled, the subtype ControlledParameterType can be used.

10.1 Temperature ToC Previous Next

Description: Setting and/or monitoring of the temperature in the main or return line (see InternalMeasuringPoint) or active external Sensor (ExternalSensorModeOn)

Unit: °C or °F

Example (for ActualValue): 120

Previous Next