9 OperationType ToC Previous Next

9.24 LDSCycleParametersEventType ToC Previous Next

The LDSCycleParametersEventType represents information on a dosing cycle. A complete dosing is defined from the beginning of the dosing signal to the next one, i.e. the event for cycle n is fired, when the dosing signal for cycle n+1 starts.

readme_files/image006.png Figure 2 Timing of LDSCycleParametersEventTyps

The LDSCycleParametersEventType is formally defined in Table 17.

Table 17 – LDSCycleParametersEventType Definition

Attribute Value        
BrowseName LDSCycleParametersEventType        
IsAbstract True        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseEventType defined in OPC UA Part 5          
0:HasProperty Variable CycleNumber 0:UInt64 0:PropertyType M
0:HasProperty Variable DosingTime 0:Duration 0:PropertyType O
0:HasComponent Variable MixingRatioTarget 0:Double 0:AnalogItemType O
0:HasComponent Variable MixingRatioActual 0:Double 0:AnalogItemType O
0:HasComponent Variable AdditivesRatioTarget 0:Double[] 0:AnalogItemType O
0:HasComponent Variable AdditivesRatioActual 0:Double[] 0:AnalogItemType O
0:HasComponent Variable VolumeA 0:Double 0:AnalogItemType O
0:HasComponent Variable VolumeB 0:Double 0:AnalogItemType O
0:HasComponent Variable VolumeAB 0:Double 0:AnalogItemType O
0:HasComponent Variable VolumeAdditives 0:Double[] 0:AnalogItemType O
0:HasComponent Variable VolumeTotal 0:Double 0:AnalogItemType O
0:HasComponent Variable ResidualAmountA 0:Double 0:AnalogItemType O
0:HasComponent Variable ResidualAmountB 0:Double 0:AnalogItemType O
0:HasComponent Variable MixingPointPressureA 0:Double 0:AnalogItemType O
0:HasComponent Variable MixingPointPressureB 0:Double 0:AnalogItemType O
0:HasComponent Variable MixingPointPressureBlender 0:Double 0:AnalogItemType O
0:HasComponent Variable AdditivesPressure 0:Double[] 0:AnalogItemType O
0:HasComponent Variable FilterPressurePrimary 0:Double 0:AnalogItemType O
0:HasComponent Variable FilterPressureSecondary 0:Double 0:AnalogItemType O

9.24.1 Cycle Number ToC Previous Next

Number of the dosing cycle. Gets counted up after each dosing cycle.

Example: 900

Previous Next