6 LDS_InterfaceType ToC Previous Next

6.1 LDS_InterfaceType Definition ToC Previous Next

This OPC UA ObjectType is used for the root Object representing a LSR dosing system with its subcomponents. It is formally defined in Table 1.

NOTE: To promote interoperability of Clients and Servers, all instantiated Devices shall be aggregated in an Object called “DeviceSet” (see OPC UA for Devices)

readme_files/image005.png Figure 1 – LDS_InterfaceType Overview

Table 1 – LDS_InterfaceType Definition

Attribute Value        
BrowseName LDS_InterfaceType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseObjectType defined in OPC UA Part 5          
0:HasComponent Object Identification   3:IdentificationType M
0:HasComponent Object MachineConfiguration   3:MachineConfigurationType M
0:HasComponent Object Operation   OperationType M
0:HasProperty Variable DisplayLanguage 0:LocaleId 0:PropertyType O, RW
0:HasProperty Variable DeviceEnabled 0:Boolean 0:PropertyType O, RW
0:GeneratesEvent ObjectType 0:HelpOffNormalAlarmType Defined in OPC 40083    

The BrowseName of the object instance shall be “LDS_<Manufacturer>_<SerialNumber>”

Example: “LDS_Reinhardt_0123456”.

NOTE: The namespace of this BrowseName is the local server URI with namespace index 1 or a vendor specific namespace with server specific namespace index (see Table 30). The BrowseNames of the nodes below are in the namespace of the specification where used Type is defined.

Example:

BrowseName Namespace Namespace index Remarks
LDS_Reinhardt_0123456 Local Server URI or vendor specific namespace 1 or server specific OPC 40082-3 only defines the LDS_InterfaceType. The instance is generated in the local server
(      
Identification http://opcfoundation.org/UA/ PlasticsRubber/LDS/ server specific The object Identification is a child of LDS_InterfaceType which is defined in OPC 40082-3
(      
Manufacturer http://opcfoundation.org/UA/DI/ server specific The variable Manufacturer is a child of IdentificationType which is defined in OPC 40083. However, it derives from the ComponentType defined in OPC 10000-100. The Variable Manufacturer is defined there.

Previous Next