OPC 40082-3: OPC UA interfaces for plastics and rubber machinery – Peripheral devices

Part 3: LSR Dosing Systems

Release 1.00.1
2021-06-21

Copyright (c) 2021 OPC Foundation
Generated on 7/22/2021 2:12:23 PM.

This document is subject to the license terms described here.

This document is a copy of the original which can be found here.

Table of Contents

1 Scope

2 Normative references

3 Terms, definitions and conventions
    3.1 Overview
    3.2 Conventions used in this document
    3.3 Abbreviations

4 General information to OPC UA interfaces for plastics and rubber machinery and OPC UA

5 Use cases

6 LDS_InterfaceType
    6.1 LDS_InterfaceType Definition
    6.2 DisplayLanguage
    6.3 DeviceEnabled

7 Identification

8 MachineConfiguration

9 OperationType
    9.1 DeviceMappingNumber
    9.2 IdentifyDevice
    9.3 HighestActiveAlarmSeverity
    9.4 ActiveErrors
    9.5 ResetAllErrors
    9.6 ResetErrorById
    9.7 SetCycleNumber
    9.8 MaterialBalanceSystemType
    9.9 ActivateMaterialBalanceSystem
    9.10 DeliveryType
    9.11 DeliveryPressure, DeliveryPressureMeasuringPoint
    9.12 DeliveryFlowrate
    9.13 ActualShotWeight
    9.14 SetShotWeight
    9.15 SetValueCompositeDensity
    9.16 MixingRatioTarget
    9.17 MaxDeviationMixingRatio, TargetDeviationMixingRatio, ActualDeviationMixingRatio
    9.18 RemainingMaterialTime
    9.19 PurgeMode
    9.20 PurgeStatus
    9.21 ActivateRemoteControl
    9.22 RemoteControlActivated
    9.23 StartDosing, StopDosing
    9.24 LDSCycleParametersEventType
        9.24.1 Cycle Number
        9.24.2 DosingTime
        9.24.3 MixingRatioTarget
        9.24.4 MixingRatioActual
        9.24.5 AdditivesRatioTarget
        9.24.6 AdditivesRatioActual
        9.24.7 VolumeA
        9.24.8 VolumeB
        9.24.9 VolumeAB
        9.24.10 VolumeAdditives
        9.24.11 VolumeTotal
        9.24.12 ResidualAmountA
        9.24.13 ResidualAmountB
        9.24.14 MixingPointPressureA
        9.24.15 MixingPointPressureB
        9.24.16 MixingPointPressureBlender
        9.24.17 AdditivesPressure
        9.24.18 FilterPressurePrimary, FilterPressureSecondary

10 ComponentType
    10.1 SetValueDensity
    10.2 SetSetValueDensity
    10.3 ActualPressure
    10.4 ResidualAmount
    10.5 RemainingMaterialTime
    10.6 AllowsCycles
    10.7 Status

11 AdditiveType
    11.1 IsPresent
    11.2 ActivateAdditive
    11.3 AdditiveActivated
    11.4 Status
    11.5 AdditiveFraction
    11.6 AdditiveStrokeVolume
    11.7 ActivateClosedLoopControl
    11.8 ClosedLoopControlActivated

12 Alarmmanagement
    12.1 ComponentAlarmType
    12.2 AdditiveAlarmType

13 Profiles and Conformance Units

14 Namespaces
    14.1 Namespace Metadata
    14.2 Handling of OPC UA Namespaces

Annex A (normative) OPC 40082-3 Namespace and mappings