TemperatureRiseMonitoringType

At maximum controller output, the temperature value must change in a given time by a specified value, otherwise there is an error in the measuring circuit.
The representation of the TemperatureRiseMonitoringType ObjectType in the address space is shown in the following table:
Name | Attribute |
---|---|
NodeId | ns=1;i=1003 |
NamespaceUri | http://opcfoundation.org/UA/PlasticsRubber/HotRunner/ |
BrowseName | TemperatureRiseMonitoringType |
NodeClass | ObjectType |
IsAbstract | False |
SubtypeOf | BaseObjectType |
The references from the TemperatureRiseMonitoringType ObjectType Node are shown in the following table:
Reference | NodeClass | BrowseName | DataType | TypeDefinition | ModellingRule |
---|---|---|---|---|---|
HasProperty | Variable | ErrorDetected | Boolean | PropertyType | Mandatory |
HasProperty | Variable | SetValueActive | Boolean | PropertyType | Mandatory |
HasComponent | Variable | SetValueTemperatureChange | Double | AnalogItemType | Optional |
HasProperty | Variable | SupervisionTime | Duration | PropertyType | Optional |