TemperatureRiseMonitoringType TOC Previous Next Specification

At maximum controller output, the temperature value must change in a given time by a specified value, otherwise there is an error in the measuring circuit.

The representation of the TemperatureRiseMonitoringType ObjectType in the address space is shown in the following table:

Name Attribute
NodeId ns=1;i=1003
NamespaceUri http://opcfoundation.org/UA/PlasticsRubber/HotRunner/
BrowseName TemperatureRiseMonitoringType
NodeClass ObjectType
IsAbstract False
SubtypeOf BaseObjectType

The references from the TemperatureRiseMonitoringType ObjectType Node are shown in the following table:

Reference NodeClass BrowseName DataType TypeDefinition ModellingRule
HasProperty Variable ErrorDetected Boolean PropertyType Mandatory
HasProperty Variable SetValueActive Boolean PropertyType Mandatory
HasComponent Variable SetValueTemperatureChange Double AnalogItemType Optional
HasProperty Variable SupervisionTime Duration PropertyType Optional