8 OPC UA ObjectTypes ToC Previous Next

8.1 Standby Management ToC Previous Next

8.1.4 EnergySavingModeType ToC Previous Next

The EnergySavingModeType provides detailed information for a specific Energy Saving Mode.

Table 19 – EnergySavingModeType Definition

Attribute Value        
BrowseName EnergySavingModeType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the BaseObjectType defined in [OPC 10000-5].          
0:HasProperty Variable ID 0:Byte 0:PropertyType M, RO
0:HasProperty Variable DynamicData 0:Boolean 0:PropertyType M, RO
0:HasComponent Variable TimeMinPause 0:Duration 0:BaseDataVariableType M, RO
0:HasComponent Variable TimeToPause 0:Duration 0:BaseDataVariableType M, RO
0:HasComponent Variable TimeMinLengthOfStay 0:Duration 0:BaseDataVariableType M, RO
0:HasComponent Variable TimeMaxLengthOfStay 0:Duration 0:BaseDataVariableType M, RO
0:HasComponent Variable RegularTimeToOperate 0:Duration 0:BaseDataVariableType M, RO
0:HasComponent Variable ModePowerConsumption 0:Float 0:AnalogUnitType M, RO
0:HasComponent Variable EnergyConsumptionToPause 0:Float 0:AnalogUnitType M, RO
0:HasComponent Variable EnergyConsumptionToOperate 0:Float 0:AnalogUnitType M, RO

The BrowseName shall contain a unique name for the Energy Saving Mode.

The ID Variable shall contain a unique mode ID for the Energy Saving Mode. The mode ID’s 0x00, 0xF0, 0xFE and 0xFF are reserved for predefined states.

DynamicData shall indicate whether the time, energy consumption and power values can vary (slightly) during runtime.

The TimeMinPause Variable shall contain the minimum pause time for this Energy Saving Mode.

The TimeToPause Variable shall contain the expected time to switch to this Energy Saving Mode.

The TimeMinLengthOfStay Variable shall contain the time of minimum stay in this Energy Saving Mode.

The TimeMaxLengthOfStay Variable shall contain the time of maximum stay in this Energy Saving Mode.

The RegularTimeToOperate Variable shall contain the time value to reach ”Ready to operate” (see Figure 1) if this Energy Saving Mode will be regularly terminated.

The ModePowerConsumption Variable shall contain the power consumption in this Energy Saving Mode. Unit: [kW].

The EnergyConsumptionToPause Variable shall contain the energy consumption from ”Ready to operate” to this Energy Saving Mode. Unit: [kWh].

The EnergyConsumptionToOperate Variable shall contain the energy consumption from this Energy Saving Mode to ”Ready to operate”. Unit: [kWh].

Mapping to PROFIenergy properties:

BrowseName PE Service PE Service Data Response Field
ID List_Energy_Saving_Modes PE_Mode_ID
TimeMinPause Get_Mode Time_min_Pause
TimeToPause Get_Mode Time_to_Pause
TimeMinLengthOfStay Get_Mode Time_min_length_of_stay
TimeMaxLengthOfStay Get_Mode Time_max_length_of_stay
RegularTimeToOperate Get_Mode Regular_time_to_operate
ModePowerConsumption Get_Mode Mode_Power_Consumption
EnergyConsumptionToPause Get_Mode Energy_Consumption_to_pause
EnergyConsumptionToOperate Get_Mode Energy_Consumption_to_operate

Previous Next