7 ISA-95 Data Representation Model ToC Previous Next

7.3 DataTypes ToC Previous Next

7.3.1 ISA95EquipmentDataType ToC Previous Next index

The ISA95EquipmentDataType is a subtype of OPC UA Structure that defines an equipment class or a specific piece of equipment, a quantity and unit of measure, an optional description, and an optional collection of properties.

The structure is defined in Table 21.

Table 21 – ISA95EquipmentDataType Structure

Name Type Description
ISA95EquipmentDataType structure  
   ID 0:String An identification of an EquipmentClass or Equipment.
   Description 0:String Optional: Additional information and description about the equipment.
            EquipmentUse 0:String Optional: Information about the expected use of the equipment, see the ISA 95 Part 2 standard for defined values.
   Quantity 0:DecimalString Optional: The quantity of the equipment.
            UoM 0:String Optional: The Unit of Measure of the quantity.
   Properties    ISA95PropertyDataType [] Optional: Any associated properties, or empty if there are no properties defined.

Table 22 is the AddressSpace definition of an ISA95EquipmentDataType.

Table 22 – ISA95EquipmentDataType AddressSpace Definition

Attribute Value        
BrowseName ISA95EquipmentDataType        
IsAbstract False        
Reference NodeClass BrowseName DataType TypeDefinition ModellingRule
Subtype of the Structure defined in OPC 10000-5          

Previous Next