<?xml version="1.0" encoding="utf-8" ?>
<!--
 * Copyright (c) 2005-2021 The OPC Foundation, Inc. All rights reserved.
 *
 * OPC Foundation MIT License 1.00
 * 
 * Permission is hereby granted, free of charge, to any person
 * obtaining a copy of this software and associated documentation
 * files (the "Software"), to deal in the Software without
 * restriction, including without limitation the rights to use,
 * copy, modify, merge, publish, distribute, sublicense, and/or sell
 * copies of the Software, and to permit persons to whom the
 * Software is furnished to do so, subject to the following
 * conditions:
 * 
 * The above copyright notice and this permission notice shall be
 * included in all copies or substantial portions of the Software.
 * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
 * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
 * OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
 * NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
 * HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
 * WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
 * FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
 * OTHER DEALINGS IN THE SOFTWARE.
 *
 * The complete license agreement can be found here:
 * http://opcfoundation.org/License/MIT/1.00/
-->

<UANodeSet xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://opcfoundation.org/UA/2011/03/UANodeSet.xsd">
  <NamespaceUris>
    <Uri>http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/Calender/</Uri>
    <Uri>http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/</Uri>
    <Uri>http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/GeneralTypes/</Uri>
  </NamespaceUris>
  <Models>
    <Model ModelUri="http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/Calender/" Version="2.00" PublicationDate="2022-05-01T00:00:00Z">
      <RequiredModel ModelUri="http://opcfoundation.org/UA/" Version="1.04.7" PublicationDate="2020-07-15T00:00:00Z" />
      <RequiredModel ModelUri="http://opcfoundation.org/UA/DI/" Version="1.02.2" PublicationDate="2020-06-02T00:00:00Z" />
      <RequiredModel ModelUri="http://opcfoundation.org/UA/Machinery/" Version="1.02.0" PublicationDate="2022-05-01T00:00:00Z" />
      <RequiredModel ModelUri="http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/" Version="1.03" PublicationDate="2021-05-10T12:00:00Z" />
      <RequiredModel ModelUri="http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/GeneralTypes/" Version="2.00" PublicationDate="2022-05-01T00:00:00Z" />
    </Model>
  </Models>
  <Aliases>
    <Alias Alias="Boolean">i=1</Alias>
    <Alias Alias="UInt16">i=5</Alias>
    <Alias Alias="Double">i=11</Alias>
    <Alias Alias="String">i=12</Alias>
    <Alias Alias="DateTime">i=13</Alias>
    <Alias Alias="LocalizedText">i=21</Alias>
    <Alias Alias="HasModellingRule">i=37</Alias>
    <Alias Alias="HasTypeDefinition">i=40</Alias>
    <Alias Alias="GeneratesEvent">i=41</Alias>
    <Alias Alias="HasSubtype">i=45</Alias>
    <Alias Alias="HasProperty">i=46</Alias>
    <Alias Alias="HasComponent">i=47</Alias>
    <Alias Alias="IdType">i=256</Alias>
    <Alias Alias="NumericRange">i=291</Alias>
    <Alias Alias="Range">i=884</Alias>
    <Alias Alias="EUInformation">i=887</Alias>
    <Alias Alias="EnumValueType">i=7594</Alias>
  </Aliases>
  <Extensions>
    <Extension>
      <ua:ModelInfo Tool="UaModeler" Hash="Bf9rYLItvL8M7ZryEFffow==" Version="1.6.5" xmlns:ua="http://unifiedautomation.com/Configuration/NodeSet.xsd" />
    </Extension>
  </Extensions>
  <UAObjectType NodeId="ns=1;i=1003" BrowseName="1:CouplingProductForcesType">
    <DisplayName>CouplingProductForcesType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/Calender/v200/docs/15</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6076</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5003" BrowseName="1:CouplingProductForce_&lt;Nr&gt;" SymbolicName="CouplingProductForce__Nr_" ParentNodeId="ns=1;i=1003">
    <DisplayName>CouplingProductForce_&lt;Nr&gt;</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6077</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6080</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6083</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1003</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6084</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6086</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6088</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6090</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6092</Reference>
      <Reference ReferenceType="HasModellingRule">i=11508</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7003</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6095</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6097</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6099</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6101</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6103</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6077" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5003" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6079</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6078</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6079" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6077" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6077</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6078" BrowseName="EURange" ParentNodeId="ns=1;i=6077" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6077</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6080" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5003" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6081</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6082</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6081" BrowseName="EnumValues" ParentNodeId="ns=1;i=6080" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6080</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6082" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6080" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6080</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6083" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5003" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6084" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6085</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6085" BrowseName="EURange" ParentNodeId="ns=1;i=6084" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6084</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6086" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6087</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6087" BrowseName="EURange" ParentNodeId="ns=1;i=6086" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6086</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6088" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6089</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6089" BrowseName="EURange" ParentNodeId="ns=1;i=6088" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6088</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6090" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6091</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6091" BrowseName="EURange" ParentNodeId="ns=1;i=6090" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6090</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6092" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5003" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6093</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6094</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6093" BrowseName="EnumValues" ParentNodeId="ns=1;i=6092" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6092</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6094" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6092" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6092</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7003" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5003" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6095" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5003" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6096</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6096" BrowseName="EURange" ParentNodeId="ns=1;i=6095" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6095</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6097" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5003" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6098</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6098" BrowseName="EURange" ParentNodeId="ns=1;i=6097" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6097</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6099" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6100</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6100" BrowseName="EURange" ParentNodeId="ns=1;i=6099" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6099</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6101" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6102</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6102" BrowseName="EURange" ParentNodeId="ns=1;i=6101" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6101</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6103" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6104</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6104" BrowseName="EURange" ParentNodeId="ns=1;i=6103" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6103</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6076" BrowseName="NodeVersion" ParentNodeId="ns=1;i=1003" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1003</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1004" BrowseName="1:CouplingProductTensionsType">
    <DisplayName>CouplingProductTensionsType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/Calender/v200/docs/16</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5004</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6105</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5004" BrowseName="1:CouplingProductTension_&lt;Nr&gt;" SymbolicName="CouplingProductTension__Nr_" ParentNodeId="ns=1;i=1004">
    <DisplayName>CouplingProductTension_&lt;Nr&gt;</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6106</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1004</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasModellingRule">i=11508</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6106" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5004" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5004</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6107</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6107" BrowseName="EURange" ParentNodeId="ns=1;i=6106" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6106</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6105" BrowseName="NodeVersion" ParentNodeId="ns=1;i=1004" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1004</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1002" BrowseName="1:Calender_InterfaceType">
    <DisplayName>Calender_InterfaceType</DisplayName>
    <Category>OPC 40084-12 Basic</Category>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/Calender/v200/docs/10</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5054</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5051</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5055</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">ns=3;i=1002</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5005" BrowseName="1:CouplingProductForces" ParentNodeId="ns=1;i=1002">
    <DisplayName>CouplingProductForces</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1003</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6109</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6109" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5005" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5005</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5054" BrowseName="1:CouplingProductTensions" ParentNodeId="ns=1;i=1002">
    <DisplayName>CouplingProductTensions</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1004</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6108</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6108" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5054" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5054</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5056" BrowseName="1:Gaps" ParentNodeId="ns=1;i=1002">
    <DisplayName>Gaps</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=3;i=1004</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6111</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6111" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5056" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5056</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5051" BrowseName="1:HorizontalPosition" ParentNodeId="ns=1;i=1002">
    <DisplayName>HorizontalPosition</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6909</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6990</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6993</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6994</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6996</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6998</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7000</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7062</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7065</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7066</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7068</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7070</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7072</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7074</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6909" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5051" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6989</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6910</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6989" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6909" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6909</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6910" BrowseName="EURange" ParentNodeId="ns=1;i=6909" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6909</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6990" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5051" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6991</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6992</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6991" BrowseName="EnumValues" ParentNodeId="ns=1;i=6990" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6990</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6992" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6990" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6990</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6993" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5051" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5051</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6994" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5051" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7076</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6995</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7076" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6994" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6994</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6995" BrowseName="EURange" ParentNodeId="ns=1;i=6994" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6994</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6996" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5051" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7077</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6997</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7077" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6996" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6996</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6997" BrowseName="EURange" ParentNodeId="ns=1;i=6996" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6996</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6998" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5051" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7078</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6999</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7078" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6998" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6998</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6999" BrowseName="EURange" ParentNodeId="ns=1;i=6998" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6998</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7000" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5051" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7079</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7061</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7079" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7000" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7000</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7061" BrowseName="EURange" ParentNodeId="ns=1;i=7000" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7000</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7062" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5051" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=7063</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7064</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7063" BrowseName="EnumValues" ParentNodeId="ns=1;i=7062" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7062</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7064" BrowseName="ValueAsText" ParentNodeId="ns=1;i=7062" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7062</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7065" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5051" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=7066" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5051" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7080</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7067</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7080" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7066" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7066</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7067" BrowseName="EURange" ParentNodeId="ns=1;i=7066" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7066</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7068" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5051" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7081</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7069</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7081" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7068" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7068</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7069" BrowseName="EURange" ParentNodeId="ns=1;i=7068" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7068</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7070" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5051" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7082</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7071</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7082" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7070" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7070</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7071" BrowseName="EURange" ParentNodeId="ns=1;i=7070" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7070</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7072" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5051" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7083</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7073</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7083" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7072" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7072</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7073" BrowseName="EURange" ParentNodeId="ns=1;i=7072" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7072</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7074" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5051" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7084</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7075</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7084" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7074" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7074</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7075" BrowseName="EURange" ParentNodeId="ns=1;i=7074" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7074</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5001" BrowseName="1:ProductForce" ParentNodeId="ns=1;i=1002">
    <DisplayName>ProductForce</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6007</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6010</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6011</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6013</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6015</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6017</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6019</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7001</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6022</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6024</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6026</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6028</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6030</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6002" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5001" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6006</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6003</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6006" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6002" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6003" BrowseName="EURange" ParentNodeId="ns=1;i=6002" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6002</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6007" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5001" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6008</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6009</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6008" BrowseName="EnumValues" ParentNodeId="ns=1;i=6007" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6007</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6009" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6007" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6007</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6010" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5001" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6011" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6032</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6012</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6032" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6011" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6011</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6012" BrowseName="EURange" ParentNodeId="ns=1;i=6011" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6011</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6013" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6033</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6014</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6033" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6013" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6013</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6014" BrowseName="EURange" ParentNodeId="ns=1;i=6013" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6013</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6015" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6034</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6016</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6034" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6015" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6015</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6016" BrowseName="EURange" ParentNodeId="ns=1;i=6015" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6015</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6017" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6035</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6018</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6035" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6017" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6017</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6018" BrowseName="EURange" ParentNodeId="ns=1;i=6017" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6017</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6019" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5001" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6020</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6021</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6020" BrowseName="EnumValues" ParentNodeId="ns=1;i=6019" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6019</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6021" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6019" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6019</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7001" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5001" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6022" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5001" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6036</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6023</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6036" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6022" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6022</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6023" BrowseName="EURange" ParentNodeId="ns=1;i=6022" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6022</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6024" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5001" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6037</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6025</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6037" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6024" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6024</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6025" BrowseName="EURange" ParentNodeId="ns=1;i=6024" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6024</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6026" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6038</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6027</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6038" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6026" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6026</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6027" BrowseName="EURange" ParentNodeId="ns=1;i=6026" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6026</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6028" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6039</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6029</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6039" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6028" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6028</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6029" BrowseName="EURange" ParentNodeId="ns=1;i=6028" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6028</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6030" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6040</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6031</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6040" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6030" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6030</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6031" BrowseName="EURange" ParentNodeId="ns=1;i=6030" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6030</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5002" BrowseName="1:ProductTension" ParentNodeId="ns=1;i=1002">
    <DisplayName>ProductTension</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6004</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6042</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6045</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6046</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6048</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6050</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6052</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6057</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6059</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6061</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6063</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6065</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6004" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5002" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6041</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6005</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6041" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6004" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6004</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6005" BrowseName="EURange" ParentNodeId="ns=1;i=6004" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6004</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6042" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5002" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6043</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6044</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6043" BrowseName="EnumValues" ParentNodeId="ns=1;i=6042" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6042</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6044" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6042" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6042</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6045" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5002" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6046" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5002" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6067</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6047</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6067" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6046" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6046</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6047" BrowseName="EURange" ParentNodeId="ns=1;i=6046" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6046</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6048" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5002" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6068</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6049</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6068" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6048" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6048</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6049" BrowseName="EURange" ParentNodeId="ns=1;i=6048" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6048</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6050" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5002" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6069</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6051</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6069" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6050" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6050</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6051" BrowseName="EURange" ParentNodeId="ns=1;i=6050" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6050</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6052" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5002" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6070</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6053</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6070" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6052" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6052</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6053" BrowseName="EURange" ParentNodeId="ns=1;i=6052" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6052</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6054" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5002" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6055</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6056</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6055" BrowseName="EnumValues" ParentNodeId="ns=1;i=6054" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6054</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6056" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6054" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6054</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7002" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5002" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6057" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5002" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6071</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6058</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6071" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6057" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6057</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6058" BrowseName="EURange" ParentNodeId="ns=1;i=6057" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6057</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6059" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5002" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6072</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6060</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6072" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6059" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6059</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6060" BrowseName="EURange" ParentNodeId="ns=1;i=6059" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6059</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6061" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5002" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6073</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6062</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6073" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6061" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6061</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6062" BrowseName="EURange" ParentNodeId="ns=1;i=6061" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6061</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6063" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5002" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6074</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6064</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6074" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6063" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6063</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6064" BrowseName="EURange" ParentNodeId="ns=1;i=6063" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6063</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6065" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5002" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6075</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6066</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6075" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6065" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6065</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6066" BrowseName="EURange" ParentNodeId="ns=1;i=6065" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6065</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5055" BrowseName="1:Rolls" ParentNodeId="ns=1;i=1002">
    <DisplayName>Rolls</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6110</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=3;i=1006</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6110" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5055" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5055</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5052" BrowseName="1:VerticalPosition" ParentNodeId="ns=1;i=1002">
    <DisplayName>VerticalPosition</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6911</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7086</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7089</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7090</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7092</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7094</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7096</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7098</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7101</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7102</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7104</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7106</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7108</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7118</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6911" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5052" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7085</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6912</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7085" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6911" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6911</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6912" BrowseName="EURange" ParentNodeId="ns=1;i=6911" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6911</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7086" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5052" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7087</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7088</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7087" BrowseName="EnumValues" ParentNodeId="ns=1;i=7086" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7086</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7088" BrowseName="ValueAsText" ParentNodeId="ns=1;i=7086" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7086</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7089" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5052" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7090" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5052" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7110</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7091</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7110" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7090" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7090</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7091" BrowseName="EURange" ParentNodeId="ns=1;i=7090" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7090</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7092" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5052" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7111</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7093</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7111" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7092" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7092</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7093" BrowseName="EURange" ParentNodeId="ns=1;i=7092" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7092</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7094" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5052" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7112</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7095</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7112" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7094" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7094</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7095" BrowseName="EURange" ParentNodeId="ns=1;i=7094" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7094</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7096" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5052" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7113</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7097</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7113" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7096" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7096</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7097" BrowseName="EURange" ParentNodeId="ns=1;i=7096" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7096</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7098" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5052" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=7099</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7100</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7099" BrowseName="EnumValues" ParentNodeId="ns=1;i=7098" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7098</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7100" BrowseName="ValueAsText" ParentNodeId="ns=1;i=7098" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7098</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7101" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5052" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=7102" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5052" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7114</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7103</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7114" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7102" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7102</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7103" BrowseName="EURange" ParentNodeId="ns=1;i=7102" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7102</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7104" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5052" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7115</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7105</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7115" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7104" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7104</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7105" BrowseName="EURange" ParentNodeId="ns=1;i=7104" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7104</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7106" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5052" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7116</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7107</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7116" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7106" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7106</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7107" BrowseName="EURange" ParentNodeId="ns=1;i=7106" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7106</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7108" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5052" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7117</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7109</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7117" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7108" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7108</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7109" BrowseName="EURange" ParentNodeId="ns=1;i=7108" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7108</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7118" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5052" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6001</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7119</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6001" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7118" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7118</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7119" BrowseName="EURange" ParentNodeId="ns=1;i=7118" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7118</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5057" BrowseName="1:http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/Calender/" SymbolicName="http___opcfoundation_org_UA_PlasticsRubber_Extrusion_v2_Calender_">
    <DisplayName>http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/Calender/</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/Calender/v200/docs/20</Documentation>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=7120</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11616</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">i=11715</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7121</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7122</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7123</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7124</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7125</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7126</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=7120" BrowseName="IsNamespaceSubset" ParentNodeId="ns=1;i=5057" DataType="Boolean">
    <DisplayName>IsNamespaceSubset</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5057</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7121" BrowseName="NamespacePublicationDate" ParentNodeId="ns=1;i=5057" DataType="DateTime">
    <DisplayName>NamespacePublicationDate</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5057</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:DateTime xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">2022-05-01T00:00:00Z</uax:DateTime>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7122" BrowseName="NamespaceUri" ParentNodeId="ns=1;i=5057" DataType="String">
    <DisplayName>NamespaceUri</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5057</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/Calender/</uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7123" BrowseName="NamespaceVersion" ParentNodeId="ns=1;i=5057" DataType="String">
    <DisplayName>NamespaceVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5057</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">2.00</uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7124" BrowseName="StaticNodeIdTypes" ParentNodeId="ns=1;i=5057" DataType="IdType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>StaticNodeIdTypes</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5057</Reference>
    </References>
    <Value>
      <uax:ListOfInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:Int32>0</uax:Int32>
            </uax:ListOfInt32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7125" BrowseName="StaticNumericNodeIdRange" ParentNodeId="ns=1;i=5057" DataType="NumericRange" ValueRank="1" ArrayDimensions="0">
    <DisplayName>StaticNumericNodeIdRange</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5057</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7126" BrowseName="StaticStringNodeIdPattern" ParentNodeId="ns=1;i=5057" DataType="String">
    <DisplayName>StaticStringNodeIdPattern</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5057</Reference>
    </References>
  </UAVariable>
</UANodeSet>