<?xml version="1.0" encoding="utf-8" ?>
<!--
 * Copyright (c) 2005-2021 The OPC Foundation, Inc. All rights reserved.
 *
 * OPC Foundation MIT License 1.00
 * 
 * Permission is hereby granted, free of charge, to any person
 * obtaining a copy of this software and associated documentation
 * files (the "Software"), to deal in the Software without
 * restriction, including without limitation the rights to use,
 * copy, modify, merge, publish, distribute, sublicense, and/or sell
 * copies of the Software, and to permit persons to whom the
 * Software is furnished to do so, subject to the following
 * conditions:
 * 
 * The above copyright notice and this permission notice shall be
 * included in all copies or substantial portions of the Software.
 * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
 * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
 * OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
 * NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
 * HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
 * WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
 * FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
 * OTHER DEALINGS IN THE SOFTWARE.
 *
 * The complete license agreement can be found here:
 * http://opcfoundation.org/License/MIT/1.00/
-->

<UANodeSet xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd" xmlns="http://opcfoundation.org/UA/2011/03/UANodeSet.xsd" xmlns:s1="http://opcfoundation.org/UA/PlasticsRubber/Extrusion/MeltPump/Types.xsd" xmlns:s2="http://opcfoundation.org/UA/PlasticsRubber/Extrusion/GeneralTypes/Types.xsd" xmlns:s3="http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/Types.xsd" xmlns:ua="http://unifiedautomation.com/Configuration/NodeSet.xsd" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
    <NamespaceUris>
        <Uri>http://opcfoundation.org/UA/PlasticsRubber/Extrusion/MeltPump/</Uri>
        <Uri>http://opcfoundation.org/UA/PlasticsRubber/Extrusion/GeneralTypes/</Uri>
        <Uri>http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/</Uri>
    </NamespaceUris>
    <Models>
        <Model ModelUri="http://opcfoundation.org/UA/PlasticsRubber/Extrusion/MeltPump/" PublicationDate="2020-06-01T00:00:00Z" Version="1.00">
            <RequiredModel ModelUri="http://opcfoundation.org/UA/" PublicationDate="2019-09-09T00:00:00Z" Version="1.04.3"/>
            <RequiredModel ModelUri="http://opcfoundation.org/UA/DI/" PublicationDate="2019-05-01T00:00:00Z" Version="1.02"/>
            <RequiredModel ModelUri="http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/" PublicationDate="2020-06-01T00:00:00Z" Version="1.02"/>
            <RequiredModel ModelUri="http://opcfoundation.org/UA/PlasticsRubber/Extrusion/GeneralTypes/" PublicationDate="2020-06-01T00:00:00Z" Version="1.00"/>
        </Model>
    </Models>
    <Aliases>
        <Alias Alias="Boolean">i=1</Alias>
        <Alias Alias="UInt16">i=5</Alias>
        <Alias Alias="Double">i=11</Alias>
        <Alias Alias="String">i=12</Alias>
        <Alias Alias="DateTime">i=13</Alias>
        <Alias Alias="LocalizedText">i=21</Alias>
        <Alias Alias="HasModellingRule">i=37</Alias>
        <Alias Alias="HasTypeDefinition">i=40</Alias>
        <Alias Alias="GeneratesEvent">i=41</Alias>
        <Alias Alias="HasSubtype">i=45</Alias>
        <Alias Alias="HasProperty">i=46</Alias>
        <Alias Alias="HasComponent">i=47</Alias>
        <Alias Alias="IdType">i=256</Alias>
        <Alias Alias="NumericRange">i=291</Alias>
        <Alias Alias="Range">i=884</Alias>
        <Alias Alias="EUInformation">i=887</Alias>
        <Alias Alias="EnumValueType">i=7594</Alias>
        <Alias Alias="MaintenanceStatusEnumeration">ns=3;i=3013</Alias>
        <Alias Alias="StartEnumeration">ns=3;i=3025</Alias>
    </Aliases>
    <Extensions>
        <Extension>
            <ua:ModelInfo Tool="UaModeler" Hash="kzlKoGdpWHwiKNxyWkuC4g==" Version="1.6.3"/>
        </Extension>
    </Extensions>
    <UAObjectType NodeId="ns=1;i=1002" BrowseName="1:MeltPump_InterfaceType">
        <DisplayName>MeltPump_InterfaceType</DisplayName>
        <References>
            <Reference ReferenceType="HasComponent">ns=1;i=5002</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6011</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=5001</Reference>
            <Reference ReferenceType="HasSubtype" IsForward="false">ns=2;i=1002</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=5005</Reference>
        </References>
    </UAObjectType>
    <UAObject ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=5002" BrowseName="1:Drive">
        <DisplayName>Drive</DisplayName>
        <References>
            <Reference ReferenceType="HasComponent">ns=1;i=5003</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
            <Reference ReferenceType="HasTypeDefinition">ns=3;i=1068</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=5004</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=5007</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=5008</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=5011</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=5012</Reference>
        </References>
    </UAObject>
    <UAObject ParentNodeId="ns=1;i=5002" NodeId="ns=1;i=5003" BrowseName="3:AdditionalMeasuringDevices">
        <DisplayName>AdditionalMeasuringDevices</DisplayName>
        <References>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
            <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
            <Reference ReferenceType="HasTypeDefinition">ns=3;i=1065</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6002</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
    </UAObject>
    <UAVariable DataType="String" ParentNodeId="ns=1;i=5003" NodeId="ns=1;i=6002" BrowseName="NodeVersion">
        <DisplayName>NodeVersion</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5003</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
        <Value>
            <uax:String></uax:String>
        </Value>
    </UAVariable>
    <UAObject ParentNodeId="ns=1;i=5002" NodeId="ns=1;i=5004" BrowseName="3:Energy">
        <DisplayName>Energy</DisplayName>
        <References>
            <Reference ReferenceType="HasComponent">ns=1;i=6009</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6018</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
            <Reference ReferenceType="HasTypeDefinition">ns=3;i=1063</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6020</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6022</Reference>
        </References>
    </UAObject>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5004" NodeId="ns=1;i=6009" BrowseName="3:ActualPower">
        <DisplayName>ActualPower</DisplayName>
        <References>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5004</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6010</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6009" NodeId="ns=1;i=6010" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6009</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5004" NodeId="ns=1;i=6018" BrowseName="3:ActualSpecificEnergy">
        <DisplayName>ActualSpecificEnergy</DisplayName>
        <References>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5004</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6019</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6018" NodeId="ns=1;i=6019" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6018</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5004" NodeId="ns=1;i=6020" BrowseName="3:PowerConsumption">
        <DisplayName>PowerConsumption</DisplayName>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6021</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5004</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6020" NodeId="ns=1;i=6021" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6020</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5004" NodeId="ns=1;i=6022" BrowseName="3:PowerFactor">
        <DisplayName>PowerFactor</DisplayName>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5004</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAObject ParentNodeId="ns=1;i=5002" NodeId="ns=1;i=5007" BrowseName="3:Maintenance">
        <DisplayName>Maintenance</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty">ns=1;i=6023</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6024</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
            <Reference ReferenceType="HasTypeDefinition">ns=3;i=1053</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6027</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=7002</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6003</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6030</Reference>
        </References>
    </UAObject>
    <UAVariable DataType="String" ParentNodeId="ns=1;i=5007" NodeId="ns=1;i=6023" BrowseName="3:AdditionalInformation">
        <DisplayName>AdditionalInformation</DisplayName>
        <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5007</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5007" NodeId="ns=1;i=6024" BrowseName="3:Interval">
        <DisplayName>Interval</DisplayName>
        <Description>Regular interval between two maintenances</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6025</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6026</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6024" NodeId="ns=1;i=6025" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6024</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6024" NodeId="ns=1;i=6026" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6024</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5007" NodeId="ns=1;i=6027" BrowseName="3:RemainingInterval">
        <DisplayName>RemainingInterval</DisplayName>
        <Description>Interval before next maintenance is due</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6028</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6029</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6027" NodeId="ns=1;i=6028" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6027</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6027" NodeId="ns=1;i=6029" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6027</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAMethod ParentNodeId="ns=1;i=5007" NodeId="ns=1;i=7002" BrowseName="3:Reset" MethodDeclarationId="ns=3;i=7046">
        <DisplayName>Reset</DisplayName>
        <Description>This Method sets the CurrentInterval to 0 and Status to NOT_DUE_0</Description>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
        </References>
    </UAMethod>
    <UAVariable DataType="MaintenanceStatusEnumeration" ParentNodeId="ns=1;i=5007" NodeId="ns=1;i=6003" BrowseName="3:Status">
        <DisplayName>Status</DisplayName>
        <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5007</Reference>
        </References>
        <Value>
            <uax:Int32>0</uax:Int32>
        </Value>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5007" NodeId="ns=1;i=6030" BrowseName="3:TotalOperation">
        <DisplayName>TotalOperation</DisplayName>
        <Description>How long is the component running in total</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6031</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6032</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6030" NodeId="ns=1;i=6031" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6030</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6030" NodeId="ns=1;i=6032" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6030</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAObject ParentNodeId="ns=1;i=5002" NodeId="ns=1;i=5008" BrowseName="3:Speed">
        <DisplayName>Speed</DisplayName>
        <References>
            <Reference ReferenceType="HasComponent">ns=1;i=6004</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6033</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6043</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6044</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6047</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6050</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6053</Reference>
            <Reference ReferenceType="HasTypeDefinition">ns=3;i=1056</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6056</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=7003</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6059</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6062</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6065</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6068</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6071</Reference>
        </References>
    </UAObject>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6004" BrowseName="3:ActualValue">
        <DisplayName>ActualValue</DisplayName>
        <Description>Actual value of the monitored parameter</Description>
        <References>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6112</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6005</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6004" NodeId="ns=1;i=6112" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6004</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6004" NodeId="ns=1;i=6005" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6004</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="UInt16" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6033" BrowseName="3:AlarmSuppression" AccessLevel="3">
        <DisplayName>AlarmSuppression</DisplayName>
        <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
        <References>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6041</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6042</Reference>
        </References>
        <Value>
            <uax:UInt16>0</uax:UInt16>
        </Value>
    </UAVariable>
    <UAVariable DataType="EnumValueType" ParentNodeId="ns=1;i=6033" ValueRank="1" NodeId="ns=1;i=6041" BrowseName="EnumValues">
        <DisplayName>EnumValues</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6033</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="LocalizedText" ParentNodeId="ns=1;i=6033" NodeId="ns=1;i=6042" BrowseName="ValueAsText">
        <DisplayName>ValueAsText</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6033</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Boolean" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6043" BrowseName="3:AutomaticMonitoring" AccessLevel="3">
        <DisplayName>AutomaticMonitoring</DisplayName>
        <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5008</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
        <Value>
            <uax:Boolean>false</uax:Boolean>
        </Value>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6044" BrowseName="3:LowerTolerance" AccessLevel="3">
        <DisplayName>LowerTolerance</DisplayName>
        <Description>Lower relative tolerance value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6045</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6046</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6044" NodeId="ns=1;i=6045" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6044</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6044" NodeId="ns=1;i=6046" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6044</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6047" BrowseName="3:LowerTolerance2" AccessLevel="3">
        <DisplayName>LowerTolerance2</DisplayName>
        <Description>Second lower relative tolerance value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6048</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6049</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6047" NodeId="ns=1;i=6048" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6047</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6047" NodeId="ns=1;i=6049" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6047</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6050" BrowseName="3:MaxValue" AccessLevel="3">
        <DisplayName>MaxValue</DisplayName>
        <Description>Maximum absolute value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6051</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6052</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6050" NodeId="ns=1;i=6051" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6050</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6050" NodeId="ns=1;i=6052" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6050</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6053" BrowseName="3:MinValue" AccessLevel="3">
        <DisplayName>MinValue</DisplayName>
        <Description>Minimum absolute value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6054</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6055</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6053" NodeId="ns=1;i=6054" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6053</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6053" NodeId="ns=1;i=6055" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6053</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="UInt16" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6056" BrowseName="3:MonitoringSensitivity" AccessLevel="3">
        <DisplayName>MonitoringSensitivity</DisplayName>
        <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
        <References>
            <Reference ReferenceType="HasProperty">ns=1;i=6057</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6058</Reference>
        </References>
        <Value>
            <uax:UInt16>0</uax:UInt16>
        </Value>
    </UAVariable>
    <UAVariable DataType="EnumValueType" ParentNodeId="ns=1;i=6056" ValueRank="1" NodeId="ns=1;i=6057" BrowseName="EnumValues">
        <DisplayName>EnumValues</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6056</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="LocalizedText" ParentNodeId="ns=1;i=6056" NodeId="ns=1;i=6058" BrowseName="ValueAsText">
        <DisplayName>ValueAsText</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6056</Reference>
        </References>
    </UAVariable>
    <UAMethod ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=7003" BrowseName="3:ResetMonitoring" MethodDeclarationId="ns=3;i=7053">
        <DisplayName>ResetMonitoring</DisplayName>
        <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
        <References>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
        </References>
    </UAMethod>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6059" BrowseName="3:SetRampDown">
        <DisplayName>SetRampDown</DisplayName>
        <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6060</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6061</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6059" NodeId="ns=1;i=6060" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6059</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6059" NodeId="ns=1;i=6061" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6059</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6062" BrowseName="3:SetRampUp">
        <DisplayName>SetRampUp</DisplayName>
        <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6063</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6064</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6062" NodeId="ns=1;i=6063" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6062</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6062" NodeId="ns=1;i=6064" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6062</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6065" BrowseName="3:SetValue" AccessLevel="3">
        <DisplayName>SetValue</DisplayName>
        <Description>Set/nominal/target value of the monitored parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6066</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6067</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6065" NodeId="ns=1;i=6066" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6065</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6065" NodeId="ns=1;i=6067" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6065</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6068" BrowseName="3:UpperTolerance" AccessLevel="3">
        <DisplayName>UpperTolerance</DisplayName>
        <Description>Upper relative tolerance value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6069</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6070</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6068" NodeId="ns=1;i=6069" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6068</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6068" NodeId="ns=1;i=6070" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6068</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5008" NodeId="ns=1;i=6071" BrowseName="3:UpperTolerance2" AccessLevel="3">
        <DisplayName>UpperTolerance2</DisplayName>
        <Description>Second upper relative tolerance value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6072</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6073</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6071" NodeId="ns=1;i=6072" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6071</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6071" NodeId="ns=1;i=6073" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6071</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAObject ParentNodeId="ns=1;i=5002" NodeId="ns=1;i=5011" BrowseName="3:StartDrive">
        <DisplayName>StartDrive</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6074</Reference>
            <Reference ReferenceType="HasTypeDefinition">ns=3;i=1023</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=7004</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6006</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=7005</Reference>
        </References>
    </UAObject>
    <UAVariable DataType="Boolean" ParentNodeId="ns=1;i=5011" NodeId="ns=1;i=6074" BrowseName="3:StartBlockedByClient" AccessLevel="3">
        <DisplayName>StartBlockedByClient</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5011</Reference>
        </References>
    </UAVariable>
    <UAMethod ParentNodeId="ns=1;i=5011" NodeId="ns=1;i=7004" BrowseName="3:StartRequest" MethodDeclarationId="ns=3;i=7051">
        <DisplayName>StartRequest</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5011</Reference>
        </References>
    </UAMethod>
    <UAVariable DataType="StartEnumeration" ParentNodeId="ns=1;i=5011" NodeId="ns=1;i=6006" BrowseName="3:Status">
        <DisplayName>Status</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5011</Reference>
        </References>
        <Value>
            <uax:Int32>0</uax:Int32>
        </Value>
    </UAVariable>
    <UAMethod ParentNodeId="ns=1;i=5011" NodeId="ns=1;i=7005" BrowseName="3:StopRequest" MethodDeclarationId="ns=3;i=7056">
        <DisplayName>StopRequest</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5011</Reference>
        </References>
    </UAMethod>
    <UAObject ParentNodeId="ns=1;i=5002" NodeId="ns=1;i=5012" BrowseName="3:Torque">
        <DisplayName>Torque</DisplayName>
        <References>
            <Reference ReferenceType="HasComponent">ns=1;i=6007</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6075</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6078</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6079</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6082</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6085</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6088</Reference>
            <Reference ReferenceType="HasTypeDefinition">ns=3;i=1056</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6091</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=7006</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6094</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6097</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6100</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6103</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6106</Reference>
        </References>
    </UAObject>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6007" BrowseName="3:ActualValue">
        <DisplayName>ActualValue</DisplayName>
        <Description>Actual value of the monitored parameter</Description>
        <References>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6113</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6008</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6007" NodeId="ns=1;i=6113" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6007</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6007" NodeId="ns=1;i=6008" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6007</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="UInt16" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6075" BrowseName="3:AlarmSuppression" AccessLevel="3">
        <DisplayName>AlarmSuppression</DisplayName>
        <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
        <References>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6076</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6077</Reference>
        </References>
        <Value>
            <uax:UInt16>0</uax:UInt16>
        </Value>
    </UAVariable>
    <UAVariable DataType="EnumValueType" ParentNodeId="ns=1;i=6075" ValueRank="1" NodeId="ns=1;i=6076" BrowseName="EnumValues">
        <DisplayName>EnumValues</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6075</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="LocalizedText" ParentNodeId="ns=1;i=6075" NodeId="ns=1;i=6077" BrowseName="ValueAsText">
        <DisplayName>ValueAsText</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6075</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Boolean" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6078" BrowseName="3:AutomaticMonitoring" AccessLevel="3">
        <DisplayName>AutomaticMonitoring</DisplayName>
        <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5012</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
        <Value>
            <uax:Boolean>false</uax:Boolean>
        </Value>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6079" BrowseName="3:LowerTolerance" AccessLevel="3">
        <DisplayName>LowerTolerance</DisplayName>
        <Description>Lower relative tolerance value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6080</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6081</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6079" NodeId="ns=1;i=6080" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6079</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6079" NodeId="ns=1;i=6081" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6079</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6082" BrowseName="3:LowerTolerance2" AccessLevel="3">
        <DisplayName>LowerTolerance2</DisplayName>
        <Description>Second lower relative tolerance value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6083</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6084</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6082" NodeId="ns=1;i=6083" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6082</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6082" NodeId="ns=1;i=6084" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6082</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6085" BrowseName="3:MaxValue" AccessLevel="3">
        <DisplayName>MaxValue</DisplayName>
        <Description>Maximum absolute value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6086</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6087</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6085" NodeId="ns=1;i=6086" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6085</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6085" NodeId="ns=1;i=6087" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6085</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6088" BrowseName="3:MinValue" AccessLevel="3">
        <DisplayName>MinValue</DisplayName>
        <Description>Minimum absolute value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6089</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6090</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6088" NodeId="ns=1;i=6089" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6088</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6088" NodeId="ns=1;i=6090" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6088</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="UInt16" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6091" BrowseName="3:MonitoringSensitivity" AccessLevel="3">
        <DisplayName>MonitoringSensitivity</DisplayName>
        <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
        <References>
            <Reference ReferenceType="HasProperty">ns=1;i=6092</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6093</Reference>
        </References>
        <Value>
            <uax:UInt16>0</uax:UInt16>
        </Value>
    </UAVariable>
    <UAVariable DataType="EnumValueType" ParentNodeId="ns=1;i=6091" ValueRank="1" NodeId="ns=1;i=6092" BrowseName="EnumValues">
        <DisplayName>EnumValues</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6091</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="LocalizedText" ParentNodeId="ns=1;i=6091" NodeId="ns=1;i=6093" BrowseName="ValueAsText">
        <DisplayName>ValueAsText</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6091</Reference>
        </References>
    </UAVariable>
    <UAMethod ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=7006" BrowseName="3:ResetMonitoring" MethodDeclarationId="ns=3;i=7053">
        <DisplayName>ResetMonitoring</DisplayName>
        <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
        <References>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
        </References>
    </UAMethod>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6094" BrowseName="3:SetRampDown">
        <DisplayName>SetRampDown</DisplayName>
        <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6095</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6096</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6094" NodeId="ns=1;i=6095" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6094</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6094" NodeId="ns=1;i=6096" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6094</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6097" BrowseName="3:SetRampUp">
        <DisplayName>SetRampUp</DisplayName>
        <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6098</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6099</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6097" NodeId="ns=1;i=6098" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6097</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6097" NodeId="ns=1;i=6099" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6097</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6100" BrowseName="3:SetValue" AccessLevel="3">
        <DisplayName>SetValue</DisplayName>
        <Description>Set/nominal/target value of the monitored parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6101</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6102</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6100" NodeId="ns=1;i=6101" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6100</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6100" NodeId="ns=1;i=6102" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6100</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6103" BrowseName="3:UpperTolerance" AccessLevel="3">
        <DisplayName>UpperTolerance</DisplayName>
        <Description>Upper relative tolerance value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6104</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6105</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6103" NodeId="ns=1;i=6104" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6103</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6103" NodeId="ns=1;i=6105" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6103</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5012" NodeId="ns=1;i=6106" BrowseName="3:UpperTolerance2" AccessLevel="3">
        <DisplayName>UpperTolerance2</DisplayName>
        <Description>Second upper relative tolerance value of the process parameter</Description>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6110</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6111</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6106" NodeId="ns=1;i=6110" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6106</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6106" NodeId="ns=1;i=6111" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6106</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=6011" BrowseName="1:FeedRate">
        <DisplayName>FeedRate</DisplayName>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6012</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6011" NodeId="ns=1;i=6012" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6011</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAObject ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=5001" BrowseName="1:MeltPressures">
        <DisplayName>MeltPressures</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">ns=3;i=1065</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6001</Reference>
        </References>
    </UAObject>
    <UAVariable DataType="String" ParentNodeId="ns=1;i=5001" NodeId="ns=1;i=6001" BrowseName="NodeVersion">
        <DisplayName>NodeVersion</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5001</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
        <Value>
            <uax:String></uax:String>
        </Value>
    </UAVariable>
    <UAObject ParentNodeId="ns=1;i=1002" NodeId="ns=1;i=5005" BrowseName="1:TemperatureZones">
        <DisplayName>TemperatureZones</DisplayName>
        <References>
            <Reference ReferenceType="HasTypeDefinition">ns=2;i=1017</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=5009</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6014</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=5006</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
        </References>
    </UAObject>
    <UAObject ParentNodeId="ns=1;i=5005" NodeId="ns=1;i=5009" BrowseName="2:Maintenance">
        <DisplayName>Maintenance</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty">ns=1;i=6034</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6035</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5005</Reference>
            <Reference ReferenceType="HasTypeDefinition">ns=3;i=1053</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6038</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=7001</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6015</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=6107</Reference>
        </References>
    </UAObject>
    <UAVariable DataType="String" ParentNodeId="ns=1;i=5009" NodeId="ns=1;i=6034" BrowseName="3:AdditionalInformation">
        <DisplayName>AdditionalInformation</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5009</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5009" NodeId="ns=1;i=6035" BrowseName="3:Interval">
        <DisplayName>Interval</DisplayName>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6036</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6037</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6035" NodeId="ns=1;i=6036" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6035</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6035" NodeId="ns=1;i=6037" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6035</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5009" NodeId="ns=1;i=6038" BrowseName="3:RemainingInterval">
        <DisplayName>RemainingInterval</DisplayName>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6039</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6040</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6038" NodeId="ns=1;i=6039" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6038</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6038" NodeId="ns=1;i=6040" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6038</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAMethod ParentNodeId="ns=1;i=5009" NodeId="ns=1;i=7001" BrowseName="3:Reset" MethodDeclarationId="ns=3;i=7046">
        <DisplayName>Reset</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
        </References>
    </UAMethod>
    <UAVariable DataType="MaintenanceStatusEnumeration" ParentNodeId="ns=1;i=5009" NodeId="ns=1;i=6015" BrowseName="3:Status">
        <DisplayName>Status</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5009</Reference>
        </References>
        <Value>
            <uax:Int32>0</uax:Int32>
        </Value>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5009" NodeId="ns=1;i=6107" BrowseName="3:TotalOperation">
        <DisplayName>TotalOperation</DisplayName>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6108</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6109</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="EUInformation" ParentNodeId="ns=1;i=6107" NodeId="ns=1;i=6108" BrowseName="EngineeringUnits">
        <DisplayName>EngineeringUnits</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6107</Reference>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Range" ParentNodeId="ns=1;i=6107" NodeId="ns=1;i=6109" BrowseName="EURange">
        <DisplayName>EURange</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6107</Reference>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="Double" ParentNodeId="ns=1;i=5005" NodeId="ns=1;i=6014" BrowseName="NodeVersion">
        <DisplayName>NodeVersion</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5005</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
        <Value>
            <uax:Double>0</uax:Double>
        </Value>
    </UAVariable>
    <UAObject ParentNodeId="ns=1;i=5005" NodeId="ns=1;i=5006" BrowseName="2:StartTempering">
        <DisplayName>StartTempering</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6114</Reference>
            <Reference ReferenceType="HasTypeDefinition">ns=3;i=1023</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=7007</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5005</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6016</Reference>
            <Reference ReferenceType="HasComponent">ns=1;i=7008</Reference>
        </References>
    </UAObject>
    <UAVariable DataType="Boolean" ParentNodeId="ns=1;i=5006" NodeId="ns=1;i=6114" BrowseName="3:StartBlockedByClient" AccessLevel="3">
        <DisplayName>StartBlockedByClient</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5006</Reference>
        </References>
    </UAVariable>
    <UAMethod ParentNodeId="ns=1;i=5006" NodeId="ns=1;i=7007" BrowseName="3:StartRequest" MethodDeclarationId="ns=3;i=7051">
        <DisplayName>StartRequest</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
        </References>
    </UAMethod>
    <UAVariable DataType="StartEnumeration" ParentNodeId="ns=1;i=5006" NodeId="ns=1;i=6016" BrowseName="3:Status">
        <DisplayName>Status</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=78</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5006</Reference>
        </References>
        <Value>
            <uax:Int32>0</uax:Int32>
        </Value>
    </UAVariable>
    <UAMethod ParentNodeId="ns=1;i=5006" NodeId="ns=1;i=7008" BrowseName="3:StopRequest" MethodDeclarationId="ns=3;i=7056">
        <DisplayName>StopRequest</DisplayName>
        <References>
            <Reference ReferenceType="HasModellingRule">i=80</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
        </References>
    </UAMethod>
    <UAObject SymbolicName="http___opcfoundation_org_UA_PlasticsRubber_Extrusion_MeltPump_" NodeId="ns=1;i=5010" BrowseName="1:http://opcfoundation.org/UA/PlasticsRubber/Extrusion/MeltPump/">
        <DisplayName>http://opcfoundation.org/UA/PlasticsRubber/Extrusion/MeltPump/</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty">ns=1;i=6013</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=11616</Reference>
            <Reference ReferenceType="HasComponent" IsForward="false">i=11715</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6017</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6116</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6117</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6118</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6119</Reference>
            <Reference ReferenceType="HasProperty">ns=1;i=6120</Reference>
        </References>
    </UAObject>
    <UAVariable DataType="Boolean" ParentNodeId="ns=1;i=5010" NodeId="ns=1;i=6013" BrowseName="IsNamespaceSubset">
        <DisplayName>IsNamespaceSubset</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
        <Value>
            <uax:Boolean>false</uax:Boolean>
        </Value>
    </UAVariable>
    <UAVariable DataType="DateTime" ParentNodeId="ns=1;i=5010" NodeId="ns=1;i=6017" BrowseName="NamespacePublicationDate">
        <DisplayName>NamespacePublicationDate</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
        <Value>
            <uax:DateTime>2020-06-01T00:00:00Z</uax:DateTime>
        </Value>
    </UAVariable>
    <UAVariable DataType="String" ParentNodeId="ns=1;i=5010" NodeId="ns=1;i=6116" BrowseName="NamespaceUri">
        <DisplayName>NamespaceUri</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
        <Value>
            <uax:String>http://opcfoundation.org/UA/PlasticsRubber/Extrusion/MeltPump/</uax:String>
        </Value>
    </UAVariable>
    <UAVariable DataType="String" ParentNodeId="ns=1;i=5010" NodeId="ns=1;i=6117" BrowseName="NamespaceVersion">
        <DisplayName>NamespaceVersion</DisplayName>
        <References>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
        </References>
        <Value>
            <uax:String>1.00</uax:String>
        </Value>
    </UAVariable>
    <UAVariable DataType="IdType" ParentNodeId="ns=1;i=5010" ValueRank="1" NodeId="ns=1;i=6118" ArrayDimensions="0" BrowseName="StaticNodeIdTypes">
        <DisplayName>StaticNodeIdTypes</DisplayName>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
        </References>
        <Value>
            <uax:ListOfInt32>
                <uax:Int32>0</uax:Int32>
            </uax:ListOfInt32>
        </Value>
    </UAVariable>
    <UAVariable DataType="NumericRange" ParentNodeId="ns=1;i=5010" ValueRank="1" NodeId="ns=1;i=6119" ArrayDimensions="0" BrowseName="StaticNumericNodeIdRange">
        <DisplayName>StaticNumericNodeIdRange</DisplayName>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
        </References>
    </UAVariable>
    <UAVariable DataType="String" ParentNodeId="ns=1;i=5010" NodeId="ns=1;i=6120" BrowseName="StaticStringNodeIdPattern">
        <DisplayName>StaticStringNodeIdPattern</DisplayName>
        <References>
            <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
            <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
        </References>
    </UAVariable>