<?xml version="1.0" encoding="utf-8" ?>
<!--
 * Copyright (c) 2005-2021 The OPC Foundation, Inc. All rights reserved.
 *
 * OPC Foundation MIT License 1.00
 * 
 * Permission is hereby granted, free of charge, to any person
 * obtaining a copy of this software and associated documentation
 * files (the "Software"), to deal in the Software without
 * restriction, including without limitation the rights to use,
 * copy, modify, merge, publish, distribute, sublicense, and/or sell
 * copies of the Software, and to permit persons to whom the
 * Software is furnished to do so, subject to the following
 * conditions:
 * 
 * The above copyright notice and this permission notice shall be
 * included in all copies or substantial portions of the Software.
 * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
 * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
 * OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
 * NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
 * HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
 * WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
 * FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
 * OTHER DEALINGS IN THE SOFTWARE.
 *
 * The complete license agreement can be found here:
 * http://opcfoundation.org/License/MIT/1.00/
-->

<UANodeSet xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://opcfoundation.org/UA/2011/03/UANodeSet.xsd">
  <NamespaceUris>
    <Uri>http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/GeneralTypes/</Uri>
    <Uri>http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/</Uri>
    <Uri>http://opcfoundation.org/UA/DI/</Uri>
    <Uri>http://opcfoundation.org/UA/Machinery/</Uri>
  </NamespaceUris>
  <Models>
    <Model ModelUri="http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/GeneralTypes/" Version="2.00" PublicationDate="2022-05-01T00:00:00Z">
      <RequiredModel ModelUri="http://opcfoundation.org/UA/" Version="1.04.7" PublicationDate="2020-07-15T00:00:00Z" />
      <RequiredModel ModelUri="http://opcfoundation.org/UA/DI/" Version="1.02.2" PublicationDate="2020-06-02T00:00:00Z" />
      <RequiredModel ModelUri="http://opcfoundation.org/UA/Machinery/" Version="1.02.0" PublicationDate="2022-05-01T00:00:00Z" />
      <RequiredModel ModelUri="http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/" Version="1.03" PublicationDate="2021-05-10T12:00:00Z" />
    </Model>
  </Models>
  <Aliases>
    <Alias Alias="Boolean">i=1</Alias>
    <Alias Alias="Byte">i=3</Alias>
    <Alias Alias="UInt16">i=5</Alias>
    <Alias Alias="UInt32">i=7</Alias>
    <Alias Alias="Double">i=11</Alias>
    <Alias Alias="String">i=12</Alias>
    <Alias Alias="DateTime">i=13</Alias>
    <Alias Alias="ByteString">i=15</Alias>
    <Alias Alias="NodeId">i=17</Alias>
    <Alias Alias="QualifiedName">i=20</Alias>
    <Alias Alias="LocalizedText">i=21</Alias>
    <Alias Alias="HasModellingRule">i=37</Alias>
    <Alias Alias="HasTypeDefinition">i=40</Alias>
    <Alias Alias="GeneratesEvent">i=41</Alias>
    <Alias Alias="HasSubtype">i=45</Alias>
    <Alias Alias="HasProperty">i=46</Alias>
    <Alias Alias="HasComponent">i=47</Alias>
    <Alias Alias="FromState">i=51</Alias>
    <Alias Alias="ToState">i=52</Alias>
    <Alias Alias="HasSubStateMachine">i=117</Alias>
    <Alias Alias="IdType">i=256</Alias>
    <Alias Alias="Duration">i=290</Alias>
    <Alias Alias="NumericRange">i=291</Alias>
    <Alias Alias="Argument">i=296</Alias>
    <Alias Alias="Range">i=884</Alias>
    <Alias Alias="EUInformation">i=887</Alias>
    <Alias Alias="EnumValueType">i=7594</Alias>
    <Alias Alias="TimeZoneDataType">i=8912</Alias>
    <Alias Alias="HasAddIn">i=17604</Alias>
    <Alias Alias="ControlModeEnumeration">ns=2;i=3001</Alias>
    <Alias Alias="ProductionDatasetInformationType">ns=2;i=3006</Alias>
    <Alias Alias="LogbookEventsEnumeration">ns=2;i=3009</Alias>
    <Alias Alias="MaintenanceStatusEnumeration">ns=2;i=3013</Alias>
    <Alias Alias="PageEntryDataType">ns=2;i=3014</Alias>
    <Alias Alias="PIDParametersDataType">ns=2;i=3023</Alias>
    <Alias Alias="StartEnumeration">ns=2;i=3025</Alias>
  </Aliases>
  <Extensions>
    <Extension>
      <ua:ModelInfo Tool="UaModeler" Hash="5IWG6ZJR95UzN22DthDp4A==" Version="1.6.5" xmlns:ua="http://unifiedautomation.com/Configuration/NodeSet.xsd" />
    </Extension>
  </Extensions>
  <UADataType NodeId="ns=1;i=3001" BrowseName="1:ExtrusionMessageClassificationEnumeration">
    <DisplayName>ExtrusionMessageClassificationEnumeration</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/7</Documentation>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6007</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=29</Reference>
    </References>
    <Definition Name="1:ExtrusionMessageClassificationEnumeration">
      <Field Name="OTHER" Value="0" />
      <Field Name="LINE_CONTROL" Value="1" />
      <Field Name="MATERIAL_HANDLING" Value="2" />
      <Field Name="PRE_HEATING" Value="3" />
      <Field Name="FEEDING" Value="4" />
      <Field Name="DOSING" Value="5" />
      <Field Name="EXTRUDER" Value="6" />
      <Field Name="VACUUM_STATION" Value="7" />
      <Field Name="FILTER" Value="8" />
      <Field Name="MELT_PUMP" Value="9" />
      <Field Name="DIE" Value="10" />
      <Field Name="COOLING" Value="11" />
      <Field Name="HAUL_OFF" Value="12" />
      <Field Name="CORRUGATOR" Value="13" />
      <Field Name="SAW" Value="14" />
      <Field Name="CALIBRATION" Value="15" />
      <Field Name="ROLL_STACK" Value="16" />
      <Field Name="MDO" Value="17" />
      <Field Name="BIAX" Value="18" />
      <Field Name="CUTTING" Value="19" />
      <Field Name="WINDER" Value="20" />
      <Field Name="PELLETIZING" Value="21" />
      <Field Name="DRYER" Value="22" />
      <Field Name="HANDLING_SYSTEM" Value="23" />
      <Field Name="LAMINATION_SYSTEM" Value="24" />
      <Field Name="MEASURING_SYSTEM" Value="25" />
      <Field Name="QUALITY_SYSTEM" Value="26" />
      <Field Name="MANUAL_INSPECTION" Value="27" />
      <Field Name="MANUAL_OPERATION" Value="28" />
    </Definition>
  </UADataType>
  <UAVariable NodeId="ns=1;i=6007" BrowseName="EnumStrings" ParentNodeId="ns=1;i=3001" DataType="LocalizedText" ValueRank="1" ArrayDimensions="29">
    <DisplayName>EnumStrings</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=3001</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:ListOfLocalizedText xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:LocalizedText>
                    <uax:Text>OTHER</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>LINE_CONTROL</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>MATERIAL_HANDLING</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>PRE_HEATING</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>FEEDING</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>DOSING</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>EXTRUDER</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>VACUUM_STATION</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>FILTER</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>MELT_PUMP</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>DIE</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>COOLING</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>HAUL_OFF</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>CORRUGATOR</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>SAW</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>CALIBRATION</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>ROLL_STACK</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>MDO</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>BIAX</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>CUTTING</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>WINDER</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>PELLETIZING</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>DRYER</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>HANDLING_SYSTEM</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>LAMINATION_SYSTEM</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>MEASURING_SYSTEM</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>QUALITY_SYSTEM</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>MANUAL_INSPECTION</uax:Text>
                </uax:LocalizedText>
                <uax:LocalizedText>
                    <uax:Text>MANUAL_OPERATION</uax:Text>
                </uax:LocalizedText>
            </uax:ListOfLocalizedText>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6008" BrowseName="1:OPC40084_1" SymbolicName="OPC40084_1_BinarySchema" DataType="ByteString">
    <DisplayName>OPC40084_1</DisplayName>
    <Description>Collects the data type descriptions of http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/GeneralTypes/</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=72</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6009</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">i=93</Reference>
    </References>
    <Value>
      <uax:ByteString xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">PG9wYzpUeXBlRGljdGlvbmFyeSB4bWxuczp4c2k9Imh0dHA6Ly93d3cudzMub3JnLzIwMDEvWE1MU2NoZ
        W1hLWluc3RhbmNlIiB4bWxuczp0bnM9Imh0dHA6Ly9vcGNmb3VuZGF0aW9uLm9yZy9VQS9Qb
        GFzdGljc1J1YmJlci9FeHRydXNpb25fdjIvR2VuZXJhbFR5cGVzLyIgRGVmYXVsdEJ5dGVPc
        mRlcj0iTGl0dGxlRW5kaWFuIiB4bWxuczpvcGM9Imh0dHA6Ly9vcGNmb3VuZGF0aW9uLm9yZ
        y9CaW5hcnlTY2hlbWEvIiB4bWxuczp1YT0iaHR0cDovL29wY2ZvdW5kYXRpb24ub3JnL1VBL
        yIgVGFyZ2V0TmFtZXNwYWNlPSJodHRwOi8vb3BjZm91bmRhdGlvbi5vcmcvVUEvUGxhc3RpY
        3NSdWJiZXIvRXh0cnVzaW9uX3YyL0dlbmVyYWxUeXBlcy8iPgogPG9wYzpJbXBvcnQgTmFtZ
        XNwYWNlPSJodHRwOi8vb3BjZm91bmRhdGlvbi5vcmcvVUEvIi8+CiA8b3BjOkVudW1lcmF0Z
        WRUeXBlIExlbmd0aEluQml0cz0iMzIiIE5hbWU9IkV4dHJ1c2lvbk1lc3NhZ2VDbGFzc2lma
        WNhdGlvbkVudW1lcmF0aW9uIj4KICA8b3BjOkVudW1lcmF0ZWRWYWx1ZSBOYW1lPSJPVEhFU
        iIgVmFsdWU9IjAiLz4KICA8b3BjOkVudW1lcmF0ZWRWYWx1ZSBOYW1lPSJMSU5FX0NPTlRST
        0wiIFZhbHVlPSIxIi8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iTUFURVJJQUxfS
        EFORExJTkciIFZhbHVlPSIyIi8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iUFJFX
        0hFQVRJTkciIFZhbHVlPSIzIi8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iRkVFR
        ElORyIgVmFsdWU9IjQiLz4KICA8b3BjOkVudW1lcmF0ZWRWYWx1ZSBOYW1lPSJET1NJTkciI
        FZhbHVlPSI1Ii8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iRVhUUlVERVIiIFZhb
        HVlPSI2Ii8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iVkFDVVVNX1NUQVRJT04iI
        FZhbHVlPSI3Ii8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iRklMVEVSIiBWYWx1Z
        T0iOCIvPgogIDxvcGM6RW51bWVyYXRlZFZhbHVlIE5hbWU9Ik1FTFRfUFVNUCIgVmFsdWU9I
        jkiLz4KICA8b3BjOkVudW1lcmF0ZWRWYWx1ZSBOYW1lPSJESUUiIFZhbHVlPSIxMCIvPgogI
        DxvcGM6RW51bWVyYXRlZFZhbHVlIE5hbWU9IkNPT0xJTkciIFZhbHVlPSIxMSIvPgogIDxvc
        GM6RW51bWVyYXRlZFZhbHVlIE5hbWU9IkhBVUxfT0ZGIiBWYWx1ZT0iMTIiLz4KICA8b3BjO
        kVudW1lcmF0ZWRWYWx1ZSBOYW1lPSJDT1JSVUdBVE9SIiBWYWx1ZT0iMTMiLz4KICA8b3BjO
        kVudW1lcmF0ZWRWYWx1ZSBOYW1lPSJTQVciIFZhbHVlPSIxNCIvPgogIDxvcGM6RW51bWVyY
        XRlZFZhbHVlIE5hbWU9IkNBTElCUkFUSU9OIiBWYWx1ZT0iMTUiLz4KICA8b3BjOkVudW1lc
        mF0ZWRWYWx1ZSBOYW1lPSJST0xMX1NUQUNLIiBWYWx1ZT0iMTYiLz4KICA8b3BjOkVudW1lc
        mF0ZWRWYWx1ZSBOYW1lPSJNRE8iIFZhbHVlPSIxNyIvPgogIDxvcGM6RW51bWVyYXRlZFZhb
        HVlIE5hbWU9IkJJQVgiIFZhbHVlPSIxOCIvPgogIDxvcGM6RW51bWVyYXRlZFZhbHVlIE5hb
        WU9IkNVVFRJTkciIFZhbHVlPSIxOSIvPgogIDxvcGM6RW51bWVyYXRlZFZhbHVlIE5hbWU9I
        ldJTkRFUiIgVmFsdWU9IjIwIi8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iUEVMT
        EVUSVpJTkciIFZhbHVlPSIyMSIvPgogIDxvcGM6RW51bWVyYXRlZFZhbHVlIE5hbWU9IkRSW
        UVSIiBWYWx1ZT0iMjIiLz4KICA8b3BjOkVudW1lcmF0ZWRWYWx1ZSBOYW1lPSJIQU5ETElOR
        19TWVNURU0iIFZhbHVlPSIyMyIvPgogIDxvcGM6RW51bWVyYXRlZFZhbHVlIE5hbWU9IkxBT
        UlOQVRJT05fU1lTVEVNIiBWYWx1ZT0iMjQiLz4KICA8b3BjOkVudW1lcmF0ZWRWYWx1ZSBOY
        W1lPSJNRUFTVVJJTkdfU1lTVEVNIiBWYWx1ZT0iMjUiLz4KICA8b3BjOkVudW1lcmF0ZWRWY
        Wx1ZSBOYW1lPSJRVUFMSVRZX1NZU1RFTSIgVmFsdWU9IjI2Ii8+CiAgPG9wYzpFbnVtZXJhd
        GVkVmFsdWUgTmFtZT0iTUFOVUFMX0lOU1BFQ1RJT04iIFZhbHVlPSIyNyIvPgogIDxvcGM6R
        W51bWVyYXRlZFZhbHVlIE5hbWU9Ik1BTlVBTF9PUEVSQVRJT04iIFZhbHVlPSIyOCIvPgogP
        C9vcGM6RW51bWVyYXRlZFR5cGU+Cjwvb3BjOlR5cGVEaWN0aW9uYXJ5Pgo=</uax:ByteString>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6009" BrowseName="NamespaceUri" ParentNodeId="ns=1;i=6008" DataType="String">
    <DisplayName>NamespaceUri</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6008</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/GeneralTypes/</uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6010" BrowseName="1:OPC40084_1" SymbolicName="OPC40084_1_XmlSchema" DataType="ByteString">
    <DisplayName>OPC40084_1</DisplayName>
    <Description>Collects the data type descriptions of http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/GeneralTypes/</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=72</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6011</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">i=92</Reference>
    </References>
    <Value>
      <uax:ByteString xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">PHhzOnNjaGVtYSBlbGVtZW50Rm9ybURlZmF1bHQ9InF1YWxpZmllZCIgdGFyZ2V0TmFtZXNwYWNlPSJod
        HRwOi8vb3BjZm91bmRhdGlvbi5vcmcvVUEvUGxhc3RpY3NSdWJiZXIvRXh0cnVzaW9uX3YyL
        0dlbmVyYWxUeXBlcy9UeXBlcy54c2QiIHhtbG5zOnRucz0iaHR0cDovL29wY2ZvdW5kYXRpb
        24ub3JnL1VBL1BsYXN0aWNzUnViYmVyL0V4dHJ1c2lvbl92Mi9HZW5lcmFsVHlwZXMvVHlwZ
        XMueHNkIiB4bWxuczp1YT0iaHR0cDovL29wY2ZvdW5kYXRpb24ub3JnL1VBLzIwMDgvMDIvV
        HlwZXMueHNkIiB4bWxuczp4cz0iaHR0cDovL3d3dy53My5vcmcvMjAwMS9YTUxTY2hlbWEiP
        gogPHhzOmltcG9ydCBuYW1lc3BhY2U9Imh0dHA6Ly9vcGNmb3VuZGF0aW9uLm9yZy9VQS8yM
        DA4LzAyL1R5cGVzLnhzZCIvPgogPHhzOnNpbXBsZVR5cGUgbmFtZT0iRXh0cnVzaW9uTWVzc
        2FnZUNsYXNzaWZpY2F0aW9uRW51bWVyYXRpb24iPgogIDx4czpyZXN0cmljdGlvbiBiYXNlP
        SJ4czpzdHJpbmciPgogICA8eHM6ZW51bWVyYXRpb24gdmFsdWU9Ik9USEVSXzAiLz4KICAgP
        HhzOmVudW1lcmF0aW9uIHZhbHVlPSJMSU5FX0NPTlRST0xfMSIvPgogICA8eHM6ZW51bWVyY
        XRpb24gdmFsdWU9Ik1BVEVSSUFMX0hBTkRMSU5HXzIiLz4KICAgPHhzOmVudW1lcmF0aW9uI
        HZhbHVlPSJQUkVfSEVBVElOR18zIi8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iRkVFR
        ElOR180Ii8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iRE9TSU5HXzUiLz4KICAgPHhzO
        mVudW1lcmF0aW9uIHZhbHVlPSJFWFRSVURFUl82Ii8+CiAgIDx4czplbnVtZXJhdGlvbiB2Y
        Wx1ZT0iVkFDVVVNX1NUQVRJT05fNyIvPgogICA8eHM6ZW51bWVyYXRpb24gdmFsdWU9IkZJT
        FRFUl84Ii8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iTUVMVF9QVU1QXzkiLz4KICAgP
        HhzOmVudW1lcmF0aW9uIHZhbHVlPSJESUVfMTAiLz4KICAgPHhzOmVudW1lcmF0aW9uIHZhb
        HVlPSJDT09MSU5HXzExIi8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iSEFVTF9PRkZfM
        TIiLz4KICAgPHhzOmVudW1lcmF0aW9uIHZhbHVlPSJDT1JSVUdBVE9SXzEzIi8+CiAgIDx4c
        zplbnVtZXJhdGlvbiB2YWx1ZT0iU0FXXzE0Ii8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1Z
        T0iQ0FMSUJSQVRJT05fMTUiLz4KICAgPHhzOmVudW1lcmF0aW9uIHZhbHVlPSJST0xMX1NUQ
        UNLXzE2Ii8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iTURPXzE3Ii8+CiAgIDx4czplb
        nVtZXJhdGlvbiB2YWx1ZT0iQklBWF8xOCIvPgogICA8eHM6ZW51bWVyYXRpb24gdmFsdWU9I
        kNVVFRJTkdfMTkiLz4KICAgPHhzOmVudW1lcmF0aW9uIHZhbHVlPSJXSU5ERVJfMjAiLz4KI
        CAgPHhzOmVudW1lcmF0aW9uIHZhbHVlPSJQRUxMRVRJWklOR18yMSIvPgogICA8eHM6ZW51b
        WVyYXRpb24gdmFsdWU9IkRSWUVSXzIyIi8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iS
        EFORExJTkdfU1lTVEVNXzIzIi8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iTEFNSU5BV
        ElPTl9TWVNURU1fMjQiLz4KICAgPHhzOmVudW1lcmF0aW9uIHZhbHVlPSJNRUFTVVJJTkdfU
        1lTVEVNXzI1Ii8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iUVVBTElUWV9TWVNURU1fM
        jYiLz4KICAgPHhzOmVudW1lcmF0aW9uIHZhbHVlPSJNQU5VQUxfSU5TUEVDVElPTl8yNyIvP
        gogICA8eHM6ZW51bWVyYXRpb24gdmFsdWU9Ik1BTlVBTF9PUEVSQVRJT05fMjgiLz4KICA8L
        3hzOnJlc3RyaWN0aW9uPgogPC94czpzaW1wbGVUeXBlPgogPHhzOmVsZW1lbnQgdHlwZT0id
        G5zOkV4dHJ1c2lvbk1lc3NhZ2VDbGFzc2lmaWNhdGlvbkVudW1lcmF0aW9uIiBuYW1lPSJFe
        HRydXNpb25NZXNzYWdlQ2xhc3NpZmljYXRpb25FbnVtZXJhdGlvbiIvPgogPHhzOmNvbXBsZ
        XhUeXBlIG5hbWU9Ikxpc3RPZkV4dHJ1c2lvbk1lc3NhZ2VDbGFzc2lmaWNhdGlvbkVudW1lc
        mF0aW9uIj4KICA8eHM6c2VxdWVuY2U+CiAgIDx4czplbGVtZW50IG1pbk9jY3Vycz0iMCIgb
        WF4T2NjdXJzPSJ1bmJvdW5kZWQiIHR5cGU9InRuczpFeHRydXNpb25NZXNzYWdlQ2xhc3NpZ
        mljYXRpb25FbnVtZXJhdGlvbiIgbmFtZT0iRXh0cnVzaW9uTWVzc2FnZUNsYXNzaWZpY2F0a
        W9uRW51bWVyYXRpb24iIG5pbGxhYmxlPSJ0cnVlIi8+CiAgPC94czpzZXF1ZW5jZT4KIDwve
        HM6Y29tcGxleFR5cGU+CiA8eHM6ZWxlbWVudCB0eXBlPSJ0bnM6TGlzdE9mRXh0cnVzaW9uT
        WVzc2FnZUNsYXNzaWZpY2F0aW9uRW51bWVyYXRpb24iIG5hbWU9Ikxpc3RPZkV4dHJ1c2lvb
        k1lc3NhZ2VDbGFzc2lmaWNhdGlvbkVudW1lcmF0aW9uIiBuaWxsYWJsZT0idHJ1ZSIvPgo8L
        3hzOnNjaGVtYT4K</uax:ByteString>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6011" BrowseName="NamespaceUri" ParentNodeId="ns=1;i=6010" DataType="String">
    <DisplayName>NamespaceUri</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6010</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/GeneralTypes/Types.xsd</uax:String>
    </Value>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1002" BrowseName="1:ExtrusionDeviceType" IsAbstract="true">
    <DisplayName>ExtrusionDeviceType</DisplayName>
    <Category>Extrusion Device</Category>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/6.1</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5023</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5011</Reference>
      <Reference ReferenceType="HasAddIn">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6035</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6020</Reference>
      <Reference ReferenceType="GeneratesEvent">ns=2;i=1011</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5065</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5013</Reference>
      <Reference ReferenceType="GeneratesEvent">ns=2;i=1004</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5014</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5018</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6037</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6702</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6036</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5023" BrowseName="1:AdditionalMeasuringDevices" ParentNodeId="ns=1;i=1002">
    <DisplayName>AdditionalMeasuringDevices</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1065</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6129</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6129" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5023" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5023</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd"></uax:String>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5010" BrowseName="1:ElectricalEnergy" ParentNodeId="ns=1;i=1002">
    <DisplayName>ElectricalEnergy</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6039</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6045</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1063</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6048</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6050</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6039" BrowseName="2:ActualPower" ParentNodeId="ns=1;i=5010" DataType="Double">
    <DisplayName>ActualPower</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6040</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6040" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6039" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6039</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6045" BrowseName="2:ActualSpecificEnergy" ParentNodeId="ns=1;i=5010" DataType="Double">
    <DisplayName>ActualSpecificEnergy</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6046</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6046" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6045" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6045</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6048" BrowseName="2:PowerConsumption" ParentNodeId="ns=1;i=5010" DataType="Double">
    <DisplayName>PowerConsumption</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6049</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6049" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6048" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6048</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6050" BrowseName="2:PowerFactor" ParentNodeId="ns=1;i=5010" DataType="Double">
    <DisplayName>PowerFactor</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5011" BrowseName="1:FluidEnergy" ParentNodeId="ns=1;i=1002">
    <DisplayName>FluidEnergy</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6041</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6047</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1063</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6054</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6056</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6041" BrowseName="2:ActualPower" ParentNodeId="ns=1;i=5011" DataType="Double">
    <DisplayName>ActualPower</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5011</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6042</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6042" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6041" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6041</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6047" BrowseName="2:ActualSpecificEnergy" ParentNodeId="ns=1;i=5011" DataType="Double">
    <DisplayName>ActualSpecificEnergy</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5011</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6051</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6051" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6047" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6047</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6054" BrowseName="2:PowerConsumption" ParentNodeId="ns=1;i=5011" DataType="Double">
    <DisplayName>PowerConsumption</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6055</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5011</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6055" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6054" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6054</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6056" BrowseName="2:PowerFactor" ParentNodeId="ns=1;i=5011" DataType="Double">
    <DisplayName>PowerFactor</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5011</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5064" BrowseName="3:Identification" ParentNodeId="ns=1;i=1002">
    <DisplayName>Identification</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6654</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6655</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6666</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6656</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6657</Reference>
      <Reference ReferenceType="HasAddIn" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6658</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6659</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=4;i=1012</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6652</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6660</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6661</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6662</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6663</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6651</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6653</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6664</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6665</Reference>
      <Reference ReferenceType="HasAddIn" IsForward="false">ns=1;i=5065</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6654" BrowseName="3:AssetId" ParentNodeId="ns=1;i=5064" DataType="String" AccessLevel="3">
    <DisplayName>AssetId</DisplayName>
    <Description Locale="en">To be used by end users to store a unique identification in the context of their overall application. Servers shall support at least 40 Unicode characters for the clients writing this value, this means clients can expect to be able to write strings with a length of 40 Unicode characters into that field.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd"></uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6655" BrowseName="3:ComponentName" ParentNodeId="ns=1;i=5064" DataType="LocalizedText" AccessLevel="3">
    <DisplayName>ComponentName</DisplayName>
    <Description Locale="en">To be used by end users to store a human-readable localized text for the MachineryItem. The minimum number of locales supported for this property shall be two. Servers shall support at least 40 Unicode characters for the clients writing the text part of each locale, this means clients can expect to be able to write texts with a length of 40 Unicode characters into that field.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:LocalizedText xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd" />
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6666" BrowseName="1:ControllerName" ParentNodeId="ns=1;i=5064" DataType="String">
    <DisplayName>ControllerName</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6656" BrowseName="3:DeviceClass" ParentNodeId="ns=1;i=5064" DataType="String">
    <DisplayName>DeviceClass</DisplayName>
    <Description Locale="en">Indicates in which domain or for what purpose the MachineryItem is used.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6657" BrowseName="3:HardwareRevision" ParentNodeId="ns=1;i=5064" DataType="String">
    <DisplayName>HardwareRevision</DisplayName>
    <Description Locale="en">A string representation of the revision level of the hardware of a MachineryItem. Hardware is physical equipment, as opposed to programs, procedures, rules and associated documentation. Many machines will not provide such information due to the modular and configurable nature of the machine.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6658" BrowseName="4:InitialOperationDate" ParentNodeId="ns=1;i=5064" DataType="DateTime">
    <DisplayName>InitialOperationDate</DisplayName>
    <Description Locale="en">The date, when the MachineryItem was switched on the first time after it has left the manufacturer plant.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6659" BrowseName="4:Location" ParentNodeId="ns=1;i=5064" DataType="String" AccessLevel="3">
    <DisplayName>Location</DisplayName>
    <Description Locale="en">To be used by end users to store the location of the machine in a scheme specific to the end user. Servers shall support at least 60 Unicode characters for the clients writing this value, this means clients can expect to be able to write strings with a length of 60 Unicode characters into that field.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6652" BrowseName="3:Manufacturer" ParentNodeId="ns=1;i=5064" DataType="LocalizedText">
    <DisplayName>Manufacturer</DisplayName>
    <Description Locale="en">A human-readable, localized name of the manufacturer of the MachineryItem.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6660" BrowseName="3:ManufacturerUri" ParentNodeId="ns=1;i=5064" DataType="String">
    <DisplayName>ManufacturerUri</DisplayName>
    <Description Locale="en">A globally unique identifier of the manufacturer of the MachineryItem.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6661" BrowseName="3:Model" ParentNodeId="ns=1;i=5064" DataType="LocalizedText">
    <DisplayName>Model</DisplayName>
    <Description Locale="en">A human-readable, localized name of the model of the MachineryItem.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6662" BrowseName="4:MonthOfConstruction" ParentNodeId="ns=1;i=5064" DataType="Byte">
    <DisplayName>MonthOfConstruction</DisplayName>
    <Description Locale="en">The month in which the manufacturing process of the MachineryItem has been completed. It shall be a number between 1 and 12, representing the month from January to December.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6663" BrowseName="3:ProductCode" ParentNodeId="ns=1;i=5064" DataType="String">
    <DisplayName>ProductCode</DisplayName>
    <Description Locale="en">A machine-readable string of the model of the MachineryItem, that might include options like the hardware configuration of the model. This information might be provided by the ERP system of the vendor. For example, it can be used as order information.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6651" BrowseName="3:ProductInstanceUri" ParentNodeId="ns=1;i=5064" DataType="String">
    <DisplayName Locale="en">ProductInstanceUri</DisplayName>
    <Description Locale="en">A globally unique resource identifier provided by the manufacturer of the machine</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6653" BrowseName="3:SerialNumber" ParentNodeId="ns=1;i=5064" DataType="String">
    <DisplayName>SerialNumber</DisplayName>
    <Description Locale="en">A string containing a unique production number of the manufacturer of the MachineryItem. The global uniqueness of the serial number is only given in the context of the manufacturer, and potentially the model. The value shall not change during the life-cycle of the MachineryItem.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6664" BrowseName="3:SoftwareRevision" ParentNodeId="ns=1;i=5064" DataType="String">
    <DisplayName>SoftwareRevision</DisplayName>
    <Description Locale="en">A string representation of the revision level of a MachineryItem. In most cases, MachineryItems consist of several software components. In that case, information about the software components might be provided as additional information in the address space, including individual revision information. In that case, this property is either not provided or provides an overall software revision level. The value might change during the life-cycle of a MachineryItem.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6665" BrowseName="4:YearOfConstruction" ParentNodeId="ns=1;i=5064" DataType="UInt16">
    <DisplayName>YearOfConstruction</DisplayName>
    <Description Locale="en">The year (Gregorian calendar) in which the manufacturing process of the MachineryItem has been completed. It shall be a four-digit number and never change during the life-cycle of a MachineryItem.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5064</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6035" BrowseName="1:IsPresent" ParentNodeId="ns=1;i=1002" DataType="Boolean">
    <DisplayName>IsPresent</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6020" BrowseName="1:LineId" ParentNodeId="ns=1;i=1002" DataType="String" AccessLevel="3">
    <DisplayName>LineId</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5009" BrowseName="1:MachineConfiguration" ParentNodeId="ns=1;i=1002">
    <DisplayName>MachineConfiguration</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=7013</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7014</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6031</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1016</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6098</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7002</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6033</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6034</Reference>
    </References>
  </UAObject>
  <UAMethod NodeId="ns=1;i=7013" BrowseName="2:GetCurrentPage" ParentNodeId="ns=1;i=5009" MethodDeclarationId="ns=2;i=7017">
    <DisplayName>GetCurrentPage</DisplayName>
    <Description>Method for retrieving a screenshot of the control system with the currently shown contents</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6094</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6095</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6094" BrowseName="InputArguments" ParentNodeId="ns=1;i=7013" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7013</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>VisualisationUnit</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=7</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6095" BrowseName="OutputArguments" ParentNodeId="ns=1;i=7013" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>OutputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7013</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>Page</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=30</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7014" BrowseName="2:GetPage" ParentNodeId="ns=1;i=5009" MethodDeclarationId="ns=2;i=7018">
    <DisplayName>GetPage</DisplayName>
    <Description>Method for retrieving the image of a page of the control system</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6096</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6097</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6096" BrowseName="InputArguments" ParentNodeId="ns=1;i=7014" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7014</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>Id</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=12</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6097" BrowseName="OutputArguments" ParentNodeId="ns=1;i=7014" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>OutputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7014</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>Page</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=30</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6031" BrowseName="2:LocationName" ParentNodeId="ns=1;i=5009" DataType="String" AccessLevel="3">
    <DisplayName>LocationName</DisplayName>
    <Description>Description of the location of the machine given by the machine operator or OPC client</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd"></uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6098" BrowseName="2:PageDirectory" ParentNodeId="ns=1;i=5009" DataType="PageEntryDataType" ValueRank="1">
    <DisplayName>PageDirectory</DisplayName>
    <Description>List of the pages that are implemented in the machine control system and are shown on the screen of the machine</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7002" BrowseName="2:SetMachineTime" ParentNodeId="ns=1;i=5009" MethodDeclarationId="ns=2;i=7019">
    <DisplayName>SetMachineTime</DisplayName>
    <Description>Method for setting the server time together with TimeZoneOffset</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6032</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6032" BrowseName="InputArguments" ParentNodeId="ns=1;i=7002" DataType="Argument" ValueRank="1" ArrayDimensions="2">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7002</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>DateTime</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=13</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>TimeZoneOffset</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=8912</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6033" BrowseName="2:TimeZoneOffset" ParentNodeId="ns=1;i=5009" DataType="TimeZoneDataType" AccessLevel="3">
    <DisplayName>TimeZoneOffset</DisplayName>
    <Description>Difference of the local time to Coordinated Universal Time (UTC) given by the machine operator or OPC client</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5009</Reference>
    </References>
    <Value>
      <uax:ExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:TypeId>
                    <uax:Identifier>i=8913</uax:Identifier>
                </uax:TypeId>
                <uax:Body>
                    <TimeZoneDataType xmlns="http://opcfoundation.org/UA/2008/02/Types.xsd">
                        <Offset>0</Offset>
                        <DaylightSavingInOffset>false</DaylightSavingInOffset>
                    </TimeZoneDataType>
                </uax:Body>
            </uax:ExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6034" BrowseName="2:UserMachineName" ParentNodeId="ns=1;i=5009" DataType="String" AccessLevel="3">
    <DisplayName>UserMachineName</DisplayName>
    <Description>Description of the machine given by the machine operator or OPC client</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5009</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd"></uax:String>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5065" BrowseName="4:MachineryBuildingBlocks" ParentNodeId="ns=1;i=1002">
    <DisplayName>MachineryBuildingBlocks</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=61</Reference>
      <Reference ReferenceType="HasAddIn">ns=1;i=5064</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasAddIn">ns=1;i=5066</Reference>
      <Reference ReferenceType="HasAddIn">ns=1;i=5081</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5066" BrowseName="4:MachineryItemState" ParentNodeId="ns=1;i=5065">
    <DisplayName>MachineryItemState</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6667</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6684</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6682</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5083</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1010</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6685</Reference>
      <Reference ReferenceType="HasAddIn" IsForward="false">ns=1;i=5065</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6667" BrowseName="AvailableStates" ParentNodeId="ns=1;i=5066" DataType="NodeId" ValueRank="1" ArrayDimensions="0">
    <DisplayName>AvailableStates</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5066</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6684" BrowseName="AvailableTransitions" ParentNodeId="ns=1;i=5066" DataType="NodeId" ValueRank="1" ArrayDimensions="0">
    <DisplayName>AvailableTransitions</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5066</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6682" BrowseName="CurrentState" ParentNodeId="ns=1;i=5066" DataType="LocalizedText">
    <DisplayName>CurrentState</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5066</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2760</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6683</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6683" BrowseName="Id" ParentNodeId="ns=1;i=6682" DataType="NodeId">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6682</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5083" BrowseName="1:ExtrusionExecutingSubState" ParentNodeId="ns=1;i=5066">
    <DisplayName>ExtrusionExecutingSubState</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6691</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6695</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6668</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5066</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6696</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6691" BrowseName="AvailableStates" ParentNodeId="ns=1;i=5083" DataType="NodeId" ValueRank="1" ArrayDimensions="0">
    <DisplayName>AvailableStates</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5083</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6695" BrowseName="AvailableTransitions" ParentNodeId="ns=1;i=5083" DataType="NodeId" ValueRank="1" ArrayDimensions="0">
    <DisplayName>AvailableTransitions</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5083</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6668" BrowseName="CurrentState" ParentNodeId="ns=1;i=5083" DataType="LocalizedText">
    <DisplayName>CurrentState</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5083</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2760</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6681</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6681" BrowseName="Id" ParentNodeId="ns=1;i=6668" DataType="NodeId">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6668</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6696" BrowseName="LastTransition" ParentNodeId="ns=1;i=5083" DataType="LocalizedText">
    <DisplayName>LastTransition</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2767</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6697</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5083</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6697" BrowseName="Id" ParentNodeId="ns=1;i=6696" DataType="NodeId">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6696</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6685" BrowseName="LastTransition" ParentNodeId="ns=1;i=5066" DataType="LocalizedText">
    <DisplayName>LastTransition</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2767</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6686</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5066</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6686" BrowseName="Id" ParentNodeId="ns=1;i=6685" DataType="NodeId">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6685</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5081" BrowseName="4:MachineryOperationMode" ParentNodeId="ns=1;i=5065">
    <DisplayName>MachineryOperationMode</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6698</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6699</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6679</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6700</Reference>
      <Reference ReferenceType="HasAddIn" IsForward="false">ns=1;i=5065</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=4;i=1008</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6698" BrowseName="AvailableStates" ParentNodeId="ns=1;i=5081" DataType="NodeId" ValueRank="1" ArrayDimensions="0">
    <DisplayName>AvailableStates</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5081</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6699" BrowseName="AvailableTransitions" ParentNodeId="ns=1;i=5081" DataType="NodeId" ValueRank="1" ArrayDimensions="0">
    <DisplayName>AvailableTransitions</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5081</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6679" BrowseName="CurrentState" ParentNodeId="ns=1;i=5081" DataType="LocalizedText">
    <DisplayName>CurrentState</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5081</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2760</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6680</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6680" BrowseName="Id" ParentNodeId="ns=1;i=6679" DataType="NodeId">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6679</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6700" BrowseName="LastTransition" ParentNodeId="ns=1;i=5081" DataType="LocalizedText">
    <DisplayName>LastTransition</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2767</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6701</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5081</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6701" BrowseName="Id" ParentNodeId="ns=1;i=6700" DataType="NodeId">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6700</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5013" BrowseName="1:Maintenance" ParentNodeId="ns=1;i=1002">
    <DisplayName>Maintenance</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6064</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6065</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6067</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7003</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6063</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6069</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6064" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5013" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5013</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6065" BrowseName="2:Interval" ParentNodeId="ns=1;i=5013" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <Description>Regular interval between two maintenances</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6101</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6066</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5013</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6101" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6065" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6065</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6066" BrowseName="EURange" ParentNodeId="ns=1;i=6065" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6065</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6067" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5013" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <Description>Interval before next maintenance is due</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6102</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6068</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5013</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6102" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6067" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6067</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6068" BrowseName="EURange" ParentNodeId="ns=1;i=6067" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6067</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7003" BrowseName="2:Reset" ParentNodeId="ns=1;i=5013" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the RemainingInterval to Interval and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5013</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6063" BrowseName="2:Status" ParentNodeId="ns=1;i=5013" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5013</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6069" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5013" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <Description>How long is the component running in total</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6103</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6070</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5013</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6103" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6069" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6069</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6070" BrowseName="EURange" ParentNodeId="ns=1;i=6069" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6069</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5012" BrowseName="1:PressureAir" ParentNodeId="ns=1;i=1002">
    <DisplayName>PressureAir</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6043</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6052</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1063</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6057</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6062</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6043" BrowseName="2:ActualPower" ParentNodeId="ns=1;i=5012" DataType="Double">
    <DisplayName>ActualPower</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6044</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6044" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6043" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6043</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6052" BrowseName="2:ActualSpecificEnergy" ParentNodeId="ns=1;i=5012" DataType="Double">
    <DisplayName>ActualSpecificEnergy</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6053" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6052" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6052</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6057" BrowseName="2:PowerConsumption" ParentNodeId="ns=1;i=5012" DataType="Double">
    <DisplayName>PowerConsumption</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6058</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6058" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6057" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6057</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6062" BrowseName="2:PowerFactor" ParentNodeId="ns=1;i=5012" DataType="Double">
    <DisplayName>PowerFactor</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5014" BrowseName="1:ProductionDatasetManagement" ParentNodeId="ns=1;i=1002">
    <DisplayName>ProductionDatasetManagement</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7009</Reference>
      <Reference ReferenceType="GeneratesEvent">ns=2;i=1011</Reference>
      <Reference ReferenceType="GeneratesEvent">ns=2;i=1004</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1008</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5016</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7012</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5015" BrowseName="2:ActiveProductionDatasetStatus" ParentNodeId="ns=1;i=5014">
    <DisplayName>ActiveProductionDatasetStatus</DisplayName>
    <Description>Status of the active production dataset</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5014</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6079</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6071</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7007</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6081</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1039</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7008</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6079" BrowseName="2:Frozen" ParentNodeId="ns=1;i=5015" DataType="Boolean" AccessLevel="3">
    <DisplayName>Frozen</DisplayName>
    <Description>Indication if changes on the machine in the production dataset are allowed</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6071" BrowseName="2:Information" ParentNodeId="ns=1;i=5015" DataType="ProductionDatasetInformationType">
    <DisplayName>Information</DisplayName>
    <Description>Set of information on the production dataset</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:ExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:TypeId>
                    <uax:Identifier>ns=2;i=5009</uax:Identifier>
                </uax:TypeId>
                <uax:Body>
                    <ProductionDatasetInformationType xmlns="http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/Types.xsd">
                        <Name></Name>
                        <Description></Description>
                        <MESId></MESId>
                        <CreationTimestamp>1900-01-01T00:00:00Z</CreationTimestamp>
                        <LastModificationTimestamp>1900-01-01T00:00:00Z</LastModificationTimestamp>
                        <LastSaveTimestamp>1900-01-01T00:00:00Z</LastSaveTimestamp>
                        <UserName></UserName>
                        <Components />
                        <Manufacturer></Manufacturer>
                        <SerialNumber></SerialNumber>
                        <Model></Model>
                        <ControllerName></ControllerName>
                        <UserMachineName></UserMachineName>
                        <LocationName></LocationName>
                        <ProductName />
                        <MouldId></MouldId>
                        <NumCavities>0</NumCavities>
                    </ProductionDatasetInformationType>
                </uax:Body>
            </uax:ExtensionObject>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7007" BrowseName="2:Load" ParentNodeId="ns=1;i=5015" MethodDeclarationId="ns=2;i=7043">
    <DisplayName>Load</DisplayName>
    <Description>Loads a production dataset from the file system of the machine to the control of the machine</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6080</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6080" BrowseName="InputArguments" ParentNodeId="ns=1;i=7007" DataType="Argument" ValueRank="1" ArrayDimensions="2">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7007</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>Name</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=12</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>Components</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=5</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6081" BrowseName="2:Modified" ParentNodeId="ns=1;i=5015" DataType="Boolean">
    <DisplayName>Modified</DisplayName>
    <Description>Indication if the production dataset has been changed after the last storage</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7008" BrowseName="2:Save" ParentNodeId="ns=1;i=5015" MethodDeclarationId="ns=2;i=7016">
    <DisplayName>Save</DisplayName>
    <Description>Stores a production dataset from the control of the machine to the file system of the machine</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6082</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5015</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6082" BrowseName="InputArguments" ParentNodeId="ns=1;i=7008" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7008</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>Name</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=12</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7009" BrowseName="2:GetProductionDatasetInformation" ParentNodeId="ns=1;i=5014" MethodDeclarationId="ns=2;i=7032">
    <DisplayName>GetProductionDatasetInformation</DisplayName>
    <Description>This Method allows reading the description of a production dataset during the file transfer from the server to the client with ProductionDatasetTransfer</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5014</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6083</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6084</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6083" BrowseName="InputArguments" ParentNodeId="ns=1;i=7009" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7009</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>fileHandle</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=7</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6084" BrowseName="OutputArguments" ParentNodeId="ns=1;i=7009" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>OutputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7009</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>Information</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>ns=2;i=3006</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5019" BrowseName="2:ProductionDatasetInPreparationStatus" ParentNodeId="ns=1;i=5014">
    <DisplayName>ProductionDatasetInPreparationStatus</DisplayName>
    <Description>Status of the production dataset in the preparation layer</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6106</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6085</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7015</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6108</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5014</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1039</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7019</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6106" BrowseName="2:Frozen" ParentNodeId="ns=1;i=5019" DataType="Boolean" AccessLevel="3">
    <DisplayName>Frozen</DisplayName>
    <Description>Indication if changes on the machine in the production dataset are allowed</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6085" BrowseName="2:Information" ParentNodeId="ns=1;i=5019" DataType="ProductionDatasetInformationType">
    <DisplayName>Information</DisplayName>
    <Description>Set of information on the production dataset</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:ExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:TypeId>
                    <uax:Identifier>ns=2;i=5009</uax:Identifier>
                </uax:TypeId>
                <uax:Body>
                    <ProductionDatasetInformationType xmlns="http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/Types.xsd">
                        <Name></Name>
                        <Description></Description>
                        <MESId></MESId>
                        <CreationTimestamp>1900-01-01T00:00:00Z</CreationTimestamp>
                        <LastModificationTimestamp>1900-01-01T00:00:00Z</LastModificationTimestamp>
                        <LastSaveTimestamp>1900-01-01T00:00:00Z</LastSaveTimestamp>
                        <UserName></UserName>
                        <Components />
                        <Manufacturer></Manufacturer>
                        <SerialNumber></SerialNumber>
                        <Model></Model>
                        <ControllerName></ControllerName>
                        <UserMachineName></UserMachineName>
                        <LocationName></LocationName>
                        <ProductName />
                        <MouldId></MouldId>
                        <NumCavities>0</NumCavities>
                    </ProductionDatasetInformationType>
                </uax:Body>
            </uax:ExtensionObject>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7015" BrowseName="2:Load" ParentNodeId="ns=1;i=5019" MethodDeclarationId="ns=2;i=7043">
    <DisplayName>Load</DisplayName>
    <Description>Loads a production dataset from the file system of the machine to the control of the machine</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6107</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6107" BrowseName="InputArguments" ParentNodeId="ns=1;i=7015" DataType="Argument" ValueRank="1" ArrayDimensions="2">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7015</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>Name</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=12</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>Components</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=5</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6108" BrowseName="2:Modified" ParentNodeId="ns=1;i=5019" DataType="Boolean">
    <DisplayName>Modified</DisplayName>
    <Description>Indication if the production dataset has been changed after the last storage</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7019" BrowseName="2:Save" ParentNodeId="ns=1;i=5019" MethodDeclarationId="ns=2;i=7016">
    <DisplayName>Save</DisplayName>
    <Description>Stores a production dataset from the control of the machine to the file system of the machine</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6109</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5019</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6109" BrowseName="InputArguments" ParentNodeId="ns=1;i=7019" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7019</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>Name</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=12</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5020" BrowseName="2:ProductionDatasetLists" ParentNodeId="ns=1;i=5014" EventNotifier="1">
    <DisplayName>ProductionDatasetLists</DisplayName>
    <Description>Functions for exchanging information on the available production datasets on client and server</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=7010</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5014</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1003</Reference>
      <Reference ReferenceType="GeneratesEvent">ns=2;i=1040</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7011</Reference>
    </References>
  </UAObject>
  <UAMethod NodeId="ns=1;i=7010" BrowseName="2:GetProductionDatasetList" ParentNodeId="ns=1;i=5020" MethodDeclarationId="ns=2;i=7001">
    <DisplayName>GetProductionDatasetList</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6086</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6087</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6086" BrowseName="InputArguments" ParentNodeId="ns=1;i=7010" DataType="Argument" ValueRank="1" ArrayDimensions="2">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7010</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>NameFilter</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=12</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>MouldId</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=12</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6087" BrowseName="OutputArguments" ParentNodeId="ns=1;i=7010" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>OutputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7010</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>ProductionDatasetList</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>ns=2;i=3006</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7011" BrowseName="2:SendProductionDatasetList" ParentNodeId="ns=1;i=5020" MethodDeclarationId="ns=2;i=7004">
    <DisplayName>SendProductionDatasetList</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6088</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5020</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6088" BrowseName="InputArguments" ParentNodeId="ns=1;i=7011" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7011</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>ProductionDatasetList</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>ns=2;i=3006</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5016" BrowseName="2:ProductionDatasetTransfer" ParentNodeId="ns=1;i=5014" EventNotifier="1">
    <DisplayName>ProductionDatasetTransfer</DisplayName>
    <Description>Transfer of production datasets between server and client</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6072</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7004</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7006</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5014</Reference>
      <Reference ReferenceType="GeneratesEvent">ns=2;i=1040</Reference>
      <Reference ReferenceType="GeneratesEvent">ns=2;i=1006</Reference>
      <Reference ReferenceType="GeneratesEvent">ns=2;i=1007</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=15744</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6072" BrowseName="ClientProcessingTimeout" ParentNodeId="ns=1;i=5016" DataType="Duration">
    <DisplayName>ClientProcessingTimeout</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5016</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7004" BrowseName="CloseAndCommit" ParentNodeId="ns=1;i=5016" MethodDeclarationId="i=15751">
    <DisplayName>CloseAndCommit</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5016</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6073</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6074</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6073" BrowseName="InputArguments" ParentNodeId="ns=1;i=7004" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7004</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>FileHandle</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=7</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6074" BrowseName="OutputArguments" ParentNodeId="ns=1;i=7004" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>OutputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7004</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>CompletionStateMachine</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=17</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7005" BrowseName="GenerateFileForRead" ParentNodeId="ns=1;i=5016" MethodDeclarationId="i=15746">
    <DisplayName>GenerateFileForRead</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5016</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6075</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6076</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6075" BrowseName="InputArguments" ParentNodeId="ns=1;i=7005" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7005</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>GenerateOptions</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>ns=2;i=3007</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6076" BrowseName="OutputArguments" ParentNodeId="ns=1;i=7005" DataType="Argument" ValueRank="1" ArrayDimensions="3">
    <DisplayName>OutputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7005</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>FileNodeId</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=17</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>FileHandle</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=7</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>CompletionStateMachine</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=17</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7006" BrowseName="GenerateFileForWrite" ParentNodeId="ns=1;i=5016" MethodDeclarationId="i=15749">
    <DisplayName>GenerateFileForWrite</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5016</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6077</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6078</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6077" BrowseName="InputArguments" ParentNodeId="ns=1;i=7006" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7006</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>GenerateOptions</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>ns=2;i=3004</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6078" BrowseName="OutputArguments" ParentNodeId="ns=1;i=7006" DataType="Argument" ValueRank="1" ArrayDimensions="2">
    <DisplayName>OutputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7006</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>FileNodeId</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=17</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>FileHandle</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=7</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7012" BrowseName="2:SendProductionDatasetInformation" ParentNodeId="ns=1;i=5014" MethodDeclarationId="ns=2;i=7045">
    <DisplayName>SendProductionDatasetInformation</DisplayName>
    <Description>This Method allows sending of the description of a production dataset during the file transfer from the client to the server with ProductionDatasetTransfer</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6089</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5014</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6089" BrowseName="InputArguments" ParentNodeId="ns=1;i=7012" DataType="Argument" ValueRank="1" ArrayDimensions="2">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7012</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>fileHandle</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>i=7</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
                <uax:ExtensionObject>
                    <uax:TypeId>
                        <uax:Identifier>i=297</uax:Identifier>
                    </uax:TypeId>
                    <uax:Body>
                        <uax:Argument>
                            <uax:Name>Information</uax:Name>
                            <uax:DataType>
                                <uax:Identifier>ns=2;i=3006</uax:Identifier>
                            </uax:DataType>
                            <uax:ValueRank>-1</uax:ValueRank>
                            <uax:ArrayDimensions />
                            <uax:Description />
                        </uax:Argument>
                    </uax:Body>
                </uax:ExtensionObject>
            </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5018" BrowseName="1:StartDevice" ParentNodeId="ns=1;i=1002">
    <DisplayName>StartDevice</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6104</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1002</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1023</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7022</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6128</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7024</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6104" BrowseName="2:StartBlockedByClient" ParentNodeId="ns=1;i=5018" DataType="Boolean" AccessLevel="3">
    <DisplayName>StartBlockedByClient</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5018</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7022" BrowseName="2:StartRequest" ParentNodeId="ns=1;i=5018" MethodDeclarationId="ns=2;i=7051">
    <DisplayName>StartRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5018</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6128" BrowseName="2:Status" ParentNodeId="ns=1;i=5018" DataType="StartEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5018</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7024" BrowseName="2:StopRequest" ParentNodeId="ns=1;i=5018" MethodDeclarationId="ns=2;i=7056">
    <DisplayName>StopRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5018</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6037" BrowseName="1:Strand" ParentNodeId="ns=1;i=1002" DataType="UInt32">
    <DisplayName>Strand</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1002</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6702" BrowseName="1:SupportedLogbookEvents" ParentNodeId="ns=1;i=1002" DataType="LogbookEventsEnumeration" ValueRank="1" ArrayDimensions="0">
    <DisplayName>SupportedLogbookEvents</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1002</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6036" BrowseName="1:Target" ParentNodeId="ns=1;i=1002" DataType="String" ValueRank="-3">
    <DisplayName>Target</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1002</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1017" BrowseName="1:ExtrusionTemperatureZonesType">
    <DisplayName>ExtrusionTemperatureZonesType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/8.1</Documentation>
    <References>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6987</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5017</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5047</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5001" BrowseName="1:Maintenance" ParentNodeId="ns=1;i=1017">
    <DisplayName>Maintenance</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6016</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6003</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1017</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7001</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6112</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6016" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5001" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6003" BrowseName="2:Interval" ParentNodeId="ns=1;i=5001" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6014</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6004</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6014" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6003" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6004" BrowseName="EURange" ParentNodeId="ns=1;i=6003" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6003</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6005" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5001" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6015</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6006</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6015" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6005" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6005</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6006" BrowseName="EURange" ParentNodeId="ns=1;i=6005" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6005</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7001" BrowseName="2:Reset" ParentNodeId="ns=1;i=5001" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6002" BrowseName="2:Status" ParentNodeId="ns=1;i=5001" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5001</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6112" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5001" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6114</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6113</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6114" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6112" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6112</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6113" BrowseName="EURange" ParentNodeId="ns=1;i=6112" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6112</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6987" BrowseName="NodeVersion" ParentNodeId="ns=1;i=1017" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1017</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:String>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5017" BrowseName="1:StartTempering" ParentNodeId="ns=1;i=1017">
    <DisplayName>StartTempering</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6167</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1023</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7016</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1017</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6174</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7017</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6167" BrowseName="2:StartBlockedByClient" ParentNodeId="ns=1;i=5017" DataType="Boolean" AccessLevel="3">
    <DisplayName>StartBlockedByClient</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5017</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7016" BrowseName="2:StartRequest" ParentNodeId="ns=1;i=5017" MethodDeclarationId="ns=2;i=7051">
    <DisplayName>StartRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5017</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6174" BrowseName="2:Status" ParentNodeId="ns=1;i=5017" DataType="StartEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5017</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7017" BrowseName="2:StopRequest" ParentNodeId="ns=1;i=5017" MethodDeclarationId="ns=2;i=7056">
    <DisplayName>StopRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5017</Reference>
    </References>
  </UAMethod>
  <UAObject NodeId="ns=1;i=5047" BrowseName="1:TemperatureZone_&lt;Nr&gt;" SymbolicName="TemperatureZone__Nr_" ParentNodeId="ns=1;i=1017">
    <DisplayName>TemperatureZone_&lt;Nr&gt;</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6115</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6117</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6120</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6121</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6001</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1016</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6110</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6111</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6125</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6127</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5004</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6132</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6134</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6136</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6139</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6140</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6142</Reference>
      <Reference ReferenceType="HasModellingRule">i=11508</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6144</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7020</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6145</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6147</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6149</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5005</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1017</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6152</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6154</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6115" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5047" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6156</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6116</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6156" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6115" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6115</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6116" BrowseName="EURange" ParentNodeId="ns=1;i=6115" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6115</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6117" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5047" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6118</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6119</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6118" BrowseName="EnumValues" ParentNodeId="ns=1;i=6117" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6117</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6119" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6117" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6117</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6120" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5047" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5002" BrowseName="2:ClosedLoopControl" ParentNodeId="ns=1;i=5047">
    <DisplayName>ClosedLoopControl</DisplayName>
    <Description>With this type the client can do settings for the closed loop control on the device for a parameter</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6158</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6157</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7021</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7023</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6159</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6158" BrowseName="2:AutomaticControllerMode" ParentNodeId="ns=1;i=5002" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticControllerMode</DisplayName>
    <Description>Determination if PID Parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6157" BrowseName="2:AutoTuningActive" ParentNodeId="ns=1;i=5002" DataType="Boolean">
    <DisplayName>AutoTuningActive</DisplayName>
    <Description>Informs if the automatic tuning is currently active</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7021" BrowseName="2:AutoTuningOff" ParentNodeId="ns=1;i=5002" MethodDeclarationId="ns=2;i=7048">
    <DisplayName>AutoTuningOff</DisplayName>
    <Description>Stops an already active self-optimisation process (no control parameters are changed)</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAMethod NodeId="ns=1;i=7023" BrowseName="2:AutoTuningOn" ParentNodeId="ns=1;i=5002" MethodDeclarationId="ns=2;i=7047">
    <DisplayName>AutoTuningOn</DisplayName>
    <Description>Starts the self-optimisation of the controller</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6159" BrowseName="2:PIDParameters" ParentNodeId="ns=1;i=5002" DataType="PIDParametersDataType" ValueRank="1" ArrayDimensions="0" AccessLevel="3">
    <DisplayName>PIDParameters</DisplayName>
    <Description>PID Parameters as array if several input signals (sensors) are used for the control</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6121" BrowseName="1:ControllerOutput" ParentNodeId="ns=1;i=5047" DataType="Double">
    <DisplayName>ControllerOutput</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6122</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6122" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6121" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6121</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6001" BrowseName="2:ControlMode" ParentNodeId="ns=1;i=5047" DataType="ControlModeEnumeration">
    <DisplayName>ControlMode</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5003" BrowseName="1:ElectricalCurrent" ParentNodeId="ns=1;i=5047">
    <DisplayName>ElectricalCurrent</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6123</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6160</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6163</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6164</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6168</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6171</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6176</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6179</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7025</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6182</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6185</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6188</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6191</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6194</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6123" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="5">
    <DisplayName>ActualValue</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6210</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6124</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6210" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6123" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6123</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6124" BrowseName="EURange" ParentNodeId="ns=1;i=6123" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6123</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6160" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5003" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6161</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6162</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6161" BrowseName="EnumValues" ParentNodeId="ns=1;i=6160" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6160</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6162" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6160" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6160</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6163" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5003" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6164" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6165</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6166</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6165" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6164" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6164</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6166" BrowseName="EURange" ParentNodeId="ns=1;i=6164" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6164</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6168" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6169</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6170</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6169" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6168" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6168</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6170" BrowseName="EURange" ParentNodeId="ns=1;i=6168" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6168</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6171" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6172</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6173</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6172" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6171" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6171</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6173" BrowseName="EURange" ParentNodeId="ns=1;i=6171" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6171</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6176" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6177</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6178</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6177" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6176" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6176</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6178" BrowseName="EURange" ParentNodeId="ns=1;i=6176" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6176</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6179" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5003" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6180</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6181</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6180" BrowseName="EnumValues" ParentNodeId="ns=1;i=6179" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6179</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6181" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6179" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6179</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7025" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5003" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6182" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5003" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6183</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6184</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6183" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6182" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6182</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6184" BrowseName="EURange" ParentNodeId="ns=1;i=6182" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6182</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6185" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5003" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6186</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6187</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6186" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6185" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6185</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6187" BrowseName="EURange" ParentNodeId="ns=1;i=6185" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6185</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6188" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6189</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6190</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6189" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6188" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6188</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6190" BrowseName="EURange" ParentNodeId="ns=1;i=6188" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6188</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6191" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6192</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6193</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6192" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6191" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6191</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6193" BrowseName="EURange" ParentNodeId="ns=1;i=6191" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6191</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6194" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6195</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6196</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6195" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6194" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6194</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6196" BrowseName="EURange" ParentNodeId="ns=1;i=6194" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6194</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6110" BrowseName="2:Id" ParentNodeId="ns=1;i=5047" DataType="String">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd"></uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6111" BrowseName="2:IsPresent" ParentNodeId="ns=1;i=5047" DataType="Boolean">
    <DisplayName>IsPresent</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6125" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5047" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6197</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6126</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6197" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6125" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6125</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6126" BrowseName="EURange" ParentNodeId="ns=1;i=6125" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6125</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6127" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5047" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6198</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6130</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6198" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6127" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6127</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6130" BrowseName="EURange" ParentNodeId="ns=1;i=6127" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6127</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5004" BrowseName="2:Maintenance" ParentNodeId="ns=1;i=5047">
    <DisplayName>Maintenance</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6211</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6212</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6215</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7018</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6131</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6218</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6211" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5004" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5004</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6212" BrowseName="2:Interval" ParentNodeId="ns=1;i=5004" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <Description>Regular interval between two maintenances</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6213</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6214</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5004</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6213" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6212" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6212</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6214" BrowseName="EURange" ParentNodeId="ns=1;i=6212" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6212</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6215" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5004" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <Description>Interval before next maintenance is due</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6216</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6217</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5004</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6216" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6215" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6215</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6217" BrowseName="EURange" ParentNodeId="ns=1;i=6215" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6215</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7018" BrowseName="2:Reset" ParentNodeId="ns=1;i=5004" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the CurrentInterval to 0 and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5004</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6131" BrowseName="2:Status" ParentNodeId="ns=1;i=5004" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5004</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6218" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5004" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <Description>How long is the component running in total</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6219</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6220</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5004</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6219" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6218" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6218</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6220" BrowseName="EURange" ParentNodeId="ns=1;i=6218" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6218</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6132" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5047" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6199</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6133</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6199" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6132" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6132</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6133" BrowseName="EURange" ParentNodeId="ns=1;i=6132" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6132</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6134" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5047" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6200</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6135</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6200" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6134" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6134</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6135" BrowseName="EURange" ParentNodeId="ns=1;i=6134" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6134</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6136" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5047" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6137</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6138</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6137" BrowseName="EnumValues" ParentNodeId="ns=1;i=6136" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6136</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6138" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6136" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6136</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6139" BrowseName="2:Name" ParentNodeId="ns=1;i=5047" DataType="LocalizedText">
    <DisplayName>Name</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:LocalizedText xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd" />
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6140" BrowseName="1:NominalCoolingPower" ParentNodeId="ns=1;i=5047" DataType="Double">
    <DisplayName>NominalCoolingPower</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6141</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6141" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6140" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6140</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6142" BrowseName="1:NominalHeatingPower" ParentNodeId="ns=1;i=5047" DataType="Double">
    <DisplayName>NominalHeatingPower</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6143</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6143" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6142" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6142</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6144" BrowseName="2:Position" ParentNodeId="ns=1;i=5047" DataType="String">
    <DisplayName>Position</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7020" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5047" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6145" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5047" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6201</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6146</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6201" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6145" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6145</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6146" BrowseName="EURange" ParentNodeId="ns=1;i=6145" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6145</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6147" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5047" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6206</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6148</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6206" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6147" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6147</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6148" BrowseName="EURange" ParentNodeId="ns=1;i=6147" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6147</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6149" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5047" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6207</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6150</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6207" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6149" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6149</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6150" BrowseName="EURange" ParentNodeId="ns=1;i=6149" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6149</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5005" BrowseName="2:StartDevice" ParentNodeId="ns=1;i=5047">
    <DisplayName>StartDevice</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6221</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1023</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7026</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6151</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7027</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6221" BrowseName="2:StartBlockedByClient" ParentNodeId="ns=1;i=5005" DataType="Boolean" AccessLevel="3">
    <DisplayName>StartBlockedByClient</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5005</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7026" BrowseName="2:StartRequest" ParentNodeId="ns=1;i=5005" MethodDeclarationId="ns=2;i=7051">
    <DisplayName>StartRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5005</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6151" BrowseName="2:Status" ParentNodeId="ns=1;i=5005" DataType="StartEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5005</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7027" BrowseName="2:StopRequest" ParentNodeId="ns=1;i=5005" MethodDeclarationId="ns=2;i=7056">
    <DisplayName>StopRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5005</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6152" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5047" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6208</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6153</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6208" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6152" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6152</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6153" BrowseName="EURange" ParentNodeId="ns=1;i=6152" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6152</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6154" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5047" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6209</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6155</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6209" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6154" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6154</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6155" BrowseName="EURange" ParentNodeId="ns=1;i=6154" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6154</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1004" BrowseName="1:GapsType">
    <DisplayName>GapsType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/9.3</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5024</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6467</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5024" BrowseName="1:Gap_&lt;Nr&gt;" SymbolicName="Gap__Nr_" ParentNodeId="ns=1;i=1004">
    <DisplayName>Gap_&lt;Nr&gt;</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5029</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5026</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1004</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1003</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6349</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6359</Reference>
      <Reference ReferenceType="HasModellingRule">i=11508</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6350</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6351</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6360</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5029" BrowseName="1:ContactForce" ParentNodeId="ns=1;i=5024">
    <DisplayName>ContactForce</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6357</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6433</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6436</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5024</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6437</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6440</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6443</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6446</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6449</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7038</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6452</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6455</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6458</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6461</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6464</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6357" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5029" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6432</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6358</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6432" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6357" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6357</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6358" BrowseName="EURange" ParentNodeId="ns=1;i=6357" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6357</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6433" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5029" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6434</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6435</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6434" BrowseName="EnumValues" ParentNodeId="ns=1;i=6433" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6433</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6435" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6433" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6433</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6436" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5029" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5029</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6437" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5029" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6438</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6439</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6438" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6437" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6437</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6439" BrowseName="EURange" ParentNodeId="ns=1;i=6437" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6437</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6440" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5029" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6441</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6442</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6441" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6440" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6440</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6442" BrowseName="EURange" ParentNodeId="ns=1;i=6440" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6440</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6443" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5029" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6444</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6445</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6444" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6443" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6443</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6445" BrowseName="EURange" ParentNodeId="ns=1;i=6443" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6443</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6446" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5029" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6447</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6448</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6447" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6446" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6446</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6448" BrowseName="EURange" ParentNodeId="ns=1;i=6446" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6446</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6449" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5029" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6450</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6451</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6450" BrowseName="EnumValues" ParentNodeId="ns=1;i=6449" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6449</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6451" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6449" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6449</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7038" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5029" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6452" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5029" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6453</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6454</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6453" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6452" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6452</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6454" BrowseName="EURange" ParentNodeId="ns=1;i=6452" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6452</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6455" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5029" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6456</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6457</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6456" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6455" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6455</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6457" BrowseName="EURange" ParentNodeId="ns=1;i=6455" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6455</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6458" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5029" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6459</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6460</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6459" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6458" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6458</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6460" BrowseName="EURange" ParentNodeId="ns=1;i=6458" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6458</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6461" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5029" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6462</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6463</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6462" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6461" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6461</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6463" BrowseName="EURange" ParentNodeId="ns=1;i=6461" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6461</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6464" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5029" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6465</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6466</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5029</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6465" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6464" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6464</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6466" BrowseName="EURange" ParentNodeId="ns=1;i=6464" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6464</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5026" BrowseName="1:DistanceLeft" ParentNodeId="ns=1;i=5024">
    <DisplayName>DistanceLeft</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6352</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6361</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6364</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5024</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6365</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6368</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6371</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6374</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6377</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7033</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6380</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6383</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6386</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6389</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6392</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6352" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5026" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6356</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6353</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6356" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6352" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6352</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6353" BrowseName="EURange" ParentNodeId="ns=1;i=6352" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6352</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6361" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5026" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6362</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6363</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6362" BrowseName="EnumValues" ParentNodeId="ns=1;i=6361" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6361</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6363" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6361" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6361</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6364" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5026" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5026</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6365" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5026" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6366</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6367</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6366" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6365" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6365</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6367" BrowseName="EURange" ParentNodeId="ns=1;i=6365" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6365</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6368" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5026" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6369</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6370</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6369" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6368" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6368</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6370" BrowseName="EURange" ParentNodeId="ns=1;i=6368" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6368</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6371" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5026" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6372</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6373</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6372" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6371" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6371</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6373" BrowseName="EURange" ParentNodeId="ns=1;i=6371" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6371</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6374" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5026" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6375</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6376</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6375" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6374" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6374</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6376" BrowseName="EURange" ParentNodeId="ns=1;i=6374" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6374</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6377" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5026" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6378</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6379</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6378" BrowseName="EnumValues" ParentNodeId="ns=1;i=6377" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6377</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6379" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6377" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6377</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7033" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5026" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6380" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5026" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6381</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6382</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6381" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6380" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6380</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6382" BrowseName="EURange" ParentNodeId="ns=1;i=6380" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6380</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6383" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5026" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6384</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6385</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6384" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6383" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6383</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6385" BrowseName="EURange" ParentNodeId="ns=1;i=6383" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6383</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6386" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5026" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6387</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6388</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6387" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6386" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6386</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6388" BrowseName="EURange" ParentNodeId="ns=1;i=6386" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6386</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6389" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5026" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6390</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6391</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6390" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6389" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6389</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6391" BrowseName="EURange" ParentNodeId="ns=1;i=6389" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6389</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6392" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5026" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6393</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6394</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6393" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6392" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6392</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6394" BrowseName="EURange" ParentNodeId="ns=1;i=6392" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6392</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5027" BrowseName="1:DistanceRight" ParentNodeId="ns=1;i=5024">
    <DisplayName>DistanceRight</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6354</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6396</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6399</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5024</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6400</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6403</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6406</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6409</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6412</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7035</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6415</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6418</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6421</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6424</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6427</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6354" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5027" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6395</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6355</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6395" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6354" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6354</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6355" BrowseName="EURange" ParentNodeId="ns=1;i=6354" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6354</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6396" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5027" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6397</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6398</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6397" BrowseName="EnumValues" ParentNodeId="ns=1;i=6396" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6396</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6398" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6396" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6396</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6399" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5027" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6400" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5027" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6401</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6402</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6401" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6400" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6400</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6402" BrowseName="EURange" ParentNodeId="ns=1;i=6400" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6400</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6403" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5027" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6404</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6405</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6404" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6403" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6403</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6405" BrowseName="EURange" ParentNodeId="ns=1;i=6403" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6403</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6406" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5027" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6407</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6408</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6407" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6406" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6406</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6408" BrowseName="EURange" ParentNodeId="ns=1;i=6406" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6406</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6409" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5027" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6410</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6411</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6410" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6409" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6409</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6411" BrowseName="EURange" ParentNodeId="ns=1;i=6409" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6409</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6412" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5027" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6413</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6414</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6413" BrowseName="EnumValues" ParentNodeId="ns=1;i=6412" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6412</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6414" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6412" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6412</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7035" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5027" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6415" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5027" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6416</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6417</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6416" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6415" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6415</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6417" BrowseName="EURange" ParentNodeId="ns=1;i=6415" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6415</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6418" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5027" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6419</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6420</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6419" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6418" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6418</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6420" BrowseName="EURange" ParentNodeId="ns=1;i=6418" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6418</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6421" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5027" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6422</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6423</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6422" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6421" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6421</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6423" BrowseName="EURange" ParentNodeId="ns=1;i=6421" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6421</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6424" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5027" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6425</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6426</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6425" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6424" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6424</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6426" BrowseName="EURange" ParentNodeId="ns=1;i=6424" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6424</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6427" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5027" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6428</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6429</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6428" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6427" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6427</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6429" BrowseName="EURange" ParentNodeId="ns=1;i=6427" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6427</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6349" BrowseName="1:Id" ParentNodeId="ns=1;i=5024" DataType="String">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5024</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6359" BrowseName="1:IsClosed" ParentNodeId="ns=1;i=5024" DataType="Boolean">
    <DisplayName>IsClosed</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5024</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6350" BrowseName="1:RollId1" ParentNodeId="ns=1;i=5024" DataType="String">
    <DisplayName>RollId1</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5024</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6351" BrowseName="1:RollId2" ParentNodeId="ns=1;i=5024" DataType="String">
    <DisplayName>RollId2</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5024</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6360" BrowseName="1:StockingGuideIsPresent" ParentNodeId="ns=1;i=5024" DataType="Boolean">
    <DisplayName>StockingGuideIsPresent</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5024</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6467" BrowseName="NodeVersion" ParentNodeId="ns=1;i=1004" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1004</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1003" BrowseName="1:GapType">
    <DisplayName>GapType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/9.4.1</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5022</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5006</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6344</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6345</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6346</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6347</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6348</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5022" BrowseName="1:ContactForce" ParentNodeId="ns=1;i=1003">
    <DisplayName>ContactForce</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6307</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6310</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6313</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1003</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6314</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6317</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6320</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6323</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6326</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7032</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6329</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6332</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6335</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6338</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6341</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6307" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5022" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6308</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6309</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6308" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6307" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6307</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6309" BrowseName="EURange" ParentNodeId="ns=1;i=6307" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6307</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6310" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5022" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6311</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6312</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6311" BrowseName="EnumValues" ParentNodeId="ns=1;i=6310" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6310</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6312" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6310" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6310</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6313" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5022" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5022</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6314" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5022" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6315</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6316</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6315" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6314" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6314</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6316" BrowseName="EURange" ParentNodeId="ns=1;i=6314" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6314</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6317" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5022" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6318</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6319</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6318" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6317" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6317</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6319" BrowseName="EURange" ParentNodeId="ns=1;i=6317" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6317</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6320" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5022" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6321</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6322</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6321" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6320" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6320</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6322" BrowseName="EURange" ParentNodeId="ns=1;i=6320" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6320</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6323" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5022" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6324</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6325</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6324" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6323" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6323</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6325" BrowseName="EURange" ParentNodeId="ns=1;i=6323" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6323</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6326" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5022" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6327</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6328</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6327" BrowseName="EnumValues" ParentNodeId="ns=1;i=6326" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6326</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6328" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6326" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6326</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7032" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5022" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6329" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5022" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6330</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6331</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6330" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6329" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6329</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6331" BrowseName="EURange" ParentNodeId="ns=1;i=6329" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6329</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6332" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5022" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6333</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6334</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6333" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6332" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6332</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6334" BrowseName="EURange" ParentNodeId="ns=1;i=6332" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6332</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6335" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5022" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6336</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6337</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6336" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6335" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6335</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6337" BrowseName="EURange" ParentNodeId="ns=1;i=6335" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6335</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6338" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5022" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6339</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6340</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6339" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6338" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6338</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6340" BrowseName="EURange" ParentNodeId="ns=1;i=6338" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6338</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6341" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5022" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6342</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6343</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6342" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6341" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6341</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6343" BrowseName="EURange" ParentNodeId="ns=1;i=6341" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6341</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5006" BrowseName="1:DistanceLeft" ParentNodeId="ns=1;i=1003">
    <DisplayName>DistanceLeft</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6222</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6225</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6228</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1003</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6229</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6232</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6235</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6238</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6241</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7028</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6253</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6256</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6259</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6262</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6265</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6222" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5006" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6223</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6224</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6223" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6222" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6222</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6224" BrowseName="EURange" ParentNodeId="ns=1;i=6222" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6222</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6225" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5006" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6226</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6227</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6226" BrowseName="EnumValues" ParentNodeId="ns=1;i=6225" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6225</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6227" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6225" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6225</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6228" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5006" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5006</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6229" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5006" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6230</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6231</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6230" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6229" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6229</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6231" BrowseName="EURange" ParentNodeId="ns=1;i=6229" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6229</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6232" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5006" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6233</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6234</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6233" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6232" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6232</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6234" BrowseName="EURange" ParentNodeId="ns=1;i=6232" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6232</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6235" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5006" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6236</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6237</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6236" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6235" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6235</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6237" BrowseName="EURange" ParentNodeId="ns=1;i=6235" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6235</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6238" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5006" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6239</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6240</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6239" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6238" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6240" BrowseName="EURange" ParentNodeId="ns=1;i=6238" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6238</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6241" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5006" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6251</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6252</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6251" BrowseName="EnumValues" ParentNodeId="ns=1;i=6241" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6241</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6252" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6241" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6241</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7028" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5006" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6253" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5006" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6254</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6255</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6254" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6253" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6253</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6255" BrowseName="EURange" ParentNodeId="ns=1;i=6253" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6253</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6256" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5006" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6257</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6258</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6257" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6256" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6256</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6258" BrowseName="EURange" ParentNodeId="ns=1;i=6256" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6256</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6259" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5006" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6260</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6261</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6260" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6259" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6259</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6261" BrowseName="EURange" ParentNodeId="ns=1;i=6259" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6259</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6262" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5006" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6263</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6264</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6263" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6262" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6262</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6264" BrowseName="EURange" ParentNodeId="ns=1;i=6262" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6262</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6265" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5006" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6266</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6267</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6266" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6265" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6265</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6267" BrowseName="EURange" ParentNodeId="ns=1;i=6265" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6265</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5007" BrowseName="1:DistanceRight" ParentNodeId="ns=1;i=1003">
    <DisplayName>DistanceRight</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6268</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6271</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6274</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1003</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6275</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6278</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6281</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6284</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6287</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7029</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6290</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6293</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6296</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6299</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6302</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6268" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5007" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6269</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6270</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6269" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6268" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6268</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6270" BrowseName="EURange" ParentNodeId="ns=1;i=6268" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6268</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6271" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5007" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6272</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6273</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6272" BrowseName="EnumValues" ParentNodeId="ns=1;i=6271" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6271</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6273" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6271" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6271</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6274" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5007" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6275" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5007" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6276</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6277</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6276" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6275" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6275</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6277" BrowseName="EURange" ParentNodeId="ns=1;i=6275" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6275</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6278" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5007" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6279</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6280</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6279" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6278" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6278</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6280" BrowseName="EURange" ParentNodeId="ns=1;i=6278" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6278</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6281" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5007" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6282</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6283</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6282" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6281" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6281</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6283" BrowseName="EURange" ParentNodeId="ns=1;i=6281" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6281</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6284" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5007" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6285</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6286</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6285" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6284" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6284</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6286" BrowseName="EURange" ParentNodeId="ns=1;i=6284" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6284</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6287" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5007" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6288</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6289</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6288" BrowseName="EnumValues" ParentNodeId="ns=1;i=6287" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6287</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6289" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6287" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6287</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7029" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5007" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6290" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5007" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6291</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6292</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6291" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6290" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6290</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6292" BrowseName="EURange" ParentNodeId="ns=1;i=6290" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6290</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6293" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5007" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6294</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6295</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6294" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6293" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6293</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6295" BrowseName="EURange" ParentNodeId="ns=1;i=6293" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6293</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6296" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5007" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6297</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6298</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6297" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6296" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6296</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6298" BrowseName="EURange" ParentNodeId="ns=1;i=6296" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6296</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6299" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5007" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6300</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6301</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6300" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6299" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6299</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6301" BrowseName="EURange" ParentNodeId="ns=1;i=6299" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6299</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6302" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5007" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6303</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6304</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6303" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6302" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6302</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6304" BrowseName="EURange" ParentNodeId="ns=1;i=6302" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6302</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6344" BrowseName="1:Id" ParentNodeId="ns=1;i=1003" DataType="String">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1003</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6345" BrowseName="1:IsClosed" ParentNodeId="ns=1;i=1003" DataType="Boolean">
    <DisplayName>IsClosed</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6346" BrowseName="1:RollId1" ParentNodeId="ns=1;i=1003" DataType="String">
    <DisplayName>RollId1</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1003</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6347" BrowseName="1:RollId2" ParentNodeId="ns=1;i=1003" DataType="String">
    <DisplayName>RollId2</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1003</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6348" BrowseName="1:StockingGuideIsPresent" ParentNodeId="ns=1;i=1003" DataType="Boolean">
    <DisplayName>StockingGuideIsPresent</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1003</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1016" BrowseName="1:ExtrusionTemperatureZoneType">
    <DisplayName>ExtrusionTemperatureZoneType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/8.2.1</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6012</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">ns=2;i=1064</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6018</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6100</Reference>
    </References>
  </UAObjectType>
  <UAVariable NodeId="ns=1;i=6012" BrowseName="1:ControllerOutput" ParentNodeId="ns=1;i=1016" DataType="Double">
    <DisplayName>ControllerOutput</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1016</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6013</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6013" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6012" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6012</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5044" BrowseName="1:ElectricalCurrent" ParentNodeId="ns=1;i=1016">
    <DisplayName>ElectricalCurrent</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6872</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6878</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6881</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1016</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6882</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6884</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6886</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6888</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6890</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7034</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6893</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6895</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6897</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6899</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6901</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6872" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="5">
    <DisplayName>ActualValue</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6877</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6873</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6877" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6872" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6872</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6873" BrowseName="EURange" ParentNodeId="ns=1;i=6872" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6872</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6878" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5044" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6879</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6880</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6879" BrowseName="EnumValues" ParentNodeId="ns=1;i=6878" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6878</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6880" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6878" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6878</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6881" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5044" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6882" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6242</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6883</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6242" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6882" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6882</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6883" BrowseName="EURange" ParentNodeId="ns=1;i=6882" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6882</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6884" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6243</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6885</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6243" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6884" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6884</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6885" BrowseName="EURange" ParentNodeId="ns=1;i=6884" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6884</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6886" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6244</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6887</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6244" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6886" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6886</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6887" BrowseName="EURange" ParentNodeId="ns=1;i=6886" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6886</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6888" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6245</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6889</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6245" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6888" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6888</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6889" BrowseName="EURange" ParentNodeId="ns=1;i=6888" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6888</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6890" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5044" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6891</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6892</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6891" BrowseName="EnumValues" ParentNodeId="ns=1;i=6890" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6890</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6892" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6890" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6890</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7034" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5044" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6893" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5044" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6246</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6894</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6246" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6893" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6893</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6894" BrowseName="EURange" ParentNodeId="ns=1;i=6893" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6893</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6895" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5044" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6247</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6896</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6247" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6895" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6895</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6896" BrowseName="EURange" ParentNodeId="ns=1;i=6895" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6895</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6897" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6248</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6898</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6248" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6897" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6897</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6898" BrowseName="EURange" ParentNodeId="ns=1;i=6897" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6897</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6899" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6249</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6900</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6249" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6899" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6899</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6900" BrowseName="EURange" ParentNodeId="ns=1;i=6899" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6899</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6901" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6250</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6902</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6250" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6901" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6901</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6902" BrowseName="EURange" ParentNodeId="ns=1;i=6901" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6901</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6018" BrowseName="1:NominalCoolingPower" ParentNodeId="ns=1;i=1016" DataType="Double">
    <DisplayName>NominalCoolingPower</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6019</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1016</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6019" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6018" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6018</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6100" BrowseName="1:NominalHeatingPower" ParentNodeId="ns=1;i=1016" DataType="Double">
    <DisplayName>NominalHeatingPower</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6105</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1016</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6105" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6100" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6100</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1007" BrowseName="1:RollBendingType">
    <DisplayName>RollBendingType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/9.2.8</Documentation>
    <References>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6305</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
    </References>
  </UAObjectType>
  <UAVariable NodeId="ns=1;i=6305" BrowseName="NodeVersion" ParentNodeId="ns=1;i=1007" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1007</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5021" BrowseName="1:ReferencePoint_&lt;Nr&gt;" SymbolicName="ReferencePoint__Nr_" ParentNodeId="ns=1;i=1007">
    <DisplayName>ReferencePoint_&lt;Nr&gt;</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6717</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6720</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6723</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5028</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6306</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6430</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6431</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6724</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6726</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5073</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6729</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1064</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6731</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6733</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6736</Reference>
      <Reference ReferenceType="HasModellingRule">i=11508</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6737</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1007</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7031</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6738</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6740</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6742</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5074</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6745</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6747</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6717" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5021" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6719</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6718</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6719" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6717" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6717</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6718" BrowseName="EURange" ParentNodeId="ns=1;i=6717" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6717</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6720" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5021" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6721</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6722</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6721" BrowseName="EnumValues" ParentNodeId="ns=1;i=6720" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6720</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6722" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6720" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6720</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6723" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5021" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5028" BrowseName="2:ClosedLoopControl" ParentNodeId="ns=1;i=5021">
    <DisplayName>ClosedLoopControl</DisplayName>
    <Description>With this type the client can do settings for the closed loop control on the device for a parameter</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6750</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6749</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7036</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7037</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6751</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6750" BrowseName="2:AutomaticControllerMode" ParentNodeId="ns=1;i=5028" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticControllerMode</DisplayName>
    <Description>Determination if PID Parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5028</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6749" BrowseName="2:AutoTuningActive" ParentNodeId="ns=1;i=5028" DataType="Boolean">
    <DisplayName>AutoTuningActive</DisplayName>
    <Description>Informs if the automatic tuning is currently active</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5028</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7036" BrowseName="2:AutoTuningOff" ParentNodeId="ns=1;i=5028" MethodDeclarationId="ns=2;i=7048">
    <DisplayName>AutoTuningOff</DisplayName>
    <Description>Stops an already active self-optimisation process (no control parameters are changed)</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5028</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAMethod NodeId="ns=1;i=7037" BrowseName="2:AutoTuningOn" ParentNodeId="ns=1;i=5028" MethodDeclarationId="ns=2;i=7047">
    <DisplayName>AutoTuningOn</DisplayName>
    <Description>Starts the self-optimisation of the controller</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5028</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6751" BrowseName="2:PIDParameters" ParentNodeId="ns=1;i=5028" DataType="PIDParametersDataType" ValueRank="1" ArrayDimensions="0" AccessLevel="3">
    <DisplayName>PIDParameters</DisplayName>
    <Description>PID Parameters as array if several input signals (sensors) are used for the control</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5028</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6306" BrowseName="2:ControlMode" ParentNodeId="ns=1;i=5021" DataType="ControlModeEnumeration">
    <DisplayName>ControlMode</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6430" BrowseName="2:Id" ParentNodeId="ns=1;i=5021" DataType="String">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd"></uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6431" BrowseName="2:IsPresent" ParentNodeId="ns=1;i=5021" DataType="Boolean">
    <DisplayName>IsPresent</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6724" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5021" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6752</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6725</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6752" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6724" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6724</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6725" BrowseName="EURange" ParentNodeId="ns=1;i=6724" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6724</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6726" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5021" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6753</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6727</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6753" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6726" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6726</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6727" BrowseName="EURange" ParentNodeId="ns=1;i=6726" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6726</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5073" BrowseName="2:Maintenance" ParentNodeId="ns=1;i=5021">
    <DisplayName>Maintenance</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6754</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6755</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6757</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7030</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6728</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6759</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6754" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5073" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5073</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6755" BrowseName="2:Interval" ParentNodeId="ns=1;i=5073" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <Description>Regular interval between two maintenances</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6769</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6756</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5073</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6769" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6755" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6755</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6756" BrowseName="EURange" ParentNodeId="ns=1;i=6755" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6755</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6757" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5073" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <Description>Interval before next maintenance is due</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6770</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6758</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5073</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6770" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6757" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6757</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6758" BrowseName="EURange" ParentNodeId="ns=1;i=6757" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6757</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7030" BrowseName="2:Reset" ParentNodeId="ns=1;i=5073" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the CurrentInterval to 0 and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5073</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6728" BrowseName="2:Status" ParentNodeId="ns=1;i=5073" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5073</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6759" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5073" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <Description>How long is the component running in total</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6771</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6760</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5073</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6771" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6759" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6759</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6760" BrowseName="EURange" ParentNodeId="ns=1;i=6759" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6759</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6729" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5021" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6761</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6730</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6761" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6729" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6729</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6730" BrowseName="EURange" ParentNodeId="ns=1;i=6729" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6729</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6731" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5021" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6762</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6732</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6762" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6731" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6731</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6732" BrowseName="EURange" ParentNodeId="ns=1;i=6731" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6731</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6733" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5021" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6734</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6735</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6734" BrowseName="EnumValues" ParentNodeId="ns=1;i=6733" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6733</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6735" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6733" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6733</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6736" BrowseName="2:Name" ParentNodeId="ns=1;i=5021" DataType="LocalizedText">
    <DisplayName>Name</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:LocalizedText xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd" />
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6737" BrowseName="2:Position" ParentNodeId="ns=1;i=5021" DataType="String">
    <DisplayName>Position</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7031" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5021" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6738" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5021" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6763</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6739</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6763" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6738" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6738</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6739" BrowseName="EURange" ParentNodeId="ns=1;i=6738" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6738</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6740" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5021" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6764</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6741</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6764" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6740" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6740</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6741" BrowseName="EURange" ParentNodeId="ns=1;i=6740" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6740</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6742" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5021" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6765</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6743</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6765" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6742" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6742</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6743" BrowseName="EURange" ParentNodeId="ns=1;i=6742" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6742</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5074" BrowseName="2:StartDevice" ParentNodeId="ns=1;i=5021">
    <DisplayName>StartDevice</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6766</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1023</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7057</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6744</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7058</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6766" BrowseName="2:StartBlockedByClient" ParentNodeId="ns=1;i=5074" DataType="Boolean" AccessLevel="3">
    <DisplayName>StartBlockedByClient</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5074</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7057" BrowseName="2:StartRequest" ParentNodeId="ns=1;i=5074" MethodDeclarationId="ns=2;i=7051">
    <DisplayName>StartRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5074</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6744" BrowseName="2:Status" ParentNodeId="ns=1;i=5074" DataType="StartEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5074</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7058" BrowseName="2:StopRequest" ParentNodeId="ns=1;i=5074" MethodDeclarationId="ns=2;i=7056">
    <DisplayName>StopRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5074</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6745" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5021" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6767</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6746</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6767" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6745" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6745</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6746" BrowseName="EURange" ParentNodeId="ns=1;i=6745" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6745</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6747" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5021" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6768</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6748</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6768" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6747" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6747</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6748" BrowseName="EURange" ParentNodeId="ns=1;i=6747" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6747</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1008" BrowseName="1:RollPeripheralDevicesType">
    <DisplayName>RollPeripheralDevicesType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/9.2.7</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5076</Reference>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5075</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6772</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5076" BrowseName="1:CleaningSystem_&lt;Nr&gt;" SymbolicName="CleaningSystem__Nr_" ParentNodeId="ns=1;i=1008">
    <DisplayName>CleaningSystem_&lt;Nr&gt;</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1008</Reference>
      <Reference ReferenceType="HasModellingRule">i=11508</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6775</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1023</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7059</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6774</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7060</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6775" BrowseName="2:StartBlockedByClient" ParentNodeId="ns=1;i=5076" DataType="Boolean" AccessLevel="3">
    <DisplayName>StartBlockedByClient</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5076</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7059" BrowseName="2:StartRequest" ParentNodeId="ns=1;i=5076" MethodDeclarationId="ns=2;i=7051">
    <DisplayName>StartRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5076</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6774" BrowseName="2:Status" ParentNodeId="ns=1;i=5076" DataType="StartEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5076</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7060" BrowseName="2:StopRequest" ParentNodeId="ns=1;i=5076" MethodDeclarationId="ns=2;i=7056">
    <DisplayName>StopRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5076</Reference>
    </References>
  </UAMethod>
  <UAObject NodeId="ns=1;i=5075" BrowseName="1:InfraredHeatingSystem_&lt;Nr&gt;" SymbolicName="InfraredHeatingSystem__Nr_" ParentNodeId="ns=1;i=1008">
    <DisplayName>InfraredHeatingSystem_&lt;Nr&gt;</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1008</Reference>
      <Reference ReferenceType="HasModellingRule">i=11508</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6776</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1023</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7061</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6773</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7062</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6776" BrowseName="2:StartBlockedByClient" ParentNodeId="ns=1;i=5075" DataType="Boolean" AccessLevel="3">
    <DisplayName>StartBlockedByClient</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5075</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7061" BrowseName="2:StartRequest" ParentNodeId="ns=1;i=5075" MethodDeclarationId="ns=2;i=7051">
    <DisplayName>StartRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5075</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6773" BrowseName="2:Status" ParentNodeId="ns=1;i=5075" DataType="StartEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5075</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7062" BrowseName="2:StopRequest" ParentNodeId="ns=1;i=5075" MethodDeclarationId="ns=2;i=7056">
    <DisplayName>StopRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5075</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6772" BrowseName="NodeVersion" ParentNodeId="ns=1;i=1008" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1008</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1006" BrowseName="1:RollsType">
    <DisplayName>RollsType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/9.1</Documentation>
    <References>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6803</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
    </References>
  </UAObjectType>
  <UAVariable NodeId="ns=1;i=6803" BrowseName="NodeVersion" ParentNodeId="ns=1;i=1006" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1006</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5052" BrowseName="1:Roll_&lt;Nr&gt;" SymbolicName="Roll__Nr_" ParentNodeId="ns=1;i=1006">
    <DisplayName>Roll_&lt;Nr&gt;</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5054</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5055</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5056</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7074</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7079</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7080</Reference>
      <Reference ReferenceType="HasModellingRule">i=11508</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1006</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5068</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5054" BrowseName="1:CrossAxisLeft" ParentNodeId="ns=1;i=5052">
    <DisplayName>CrossAxisLeft</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6806</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6808</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6811</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6812</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6815</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6818</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6821</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6824</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7065</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6827</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6830</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6833</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6836</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6839</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6806" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5054" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6903</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6807</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6903" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6806" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6806</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6807" BrowseName="EURange" ParentNodeId="ns=1;i=6806" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6806</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6808" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5054" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6809</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6810</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6809" BrowseName="EnumValues" ParentNodeId="ns=1;i=6808" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6808</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6810" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6808" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6808</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6811" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5054" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6812" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5054" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6813</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6814</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6813" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6812" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6812</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6814" BrowseName="EURange" ParentNodeId="ns=1;i=6812" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6812</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6815" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5054" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6816</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6817</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6816" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6815" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6815</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6817" BrowseName="EURange" ParentNodeId="ns=1;i=6815" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6815</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6818" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5054" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6819</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6820</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6819" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6818" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6818</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6820" BrowseName="EURange" ParentNodeId="ns=1;i=6818" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6818</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6821" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5054" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6822</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6823</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6822" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6821" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6821</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6823" BrowseName="EURange" ParentNodeId="ns=1;i=6821" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6821</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6824" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5054" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6825</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6826</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6825" BrowseName="EnumValues" ParentNodeId="ns=1;i=6824" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6824</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6826" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6824" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6824</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7065" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5054" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6827" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5054" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6828</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6829</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6828" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6827" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6827</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6829" BrowseName="EURange" ParentNodeId="ns=1;i=6827" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6827</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6830" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5054" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6831</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6832</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6831" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6830" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6830</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6832" BrowseName="EURange" ParentNodeId="ns=1;i=6830" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6830</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6833" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5054" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6834</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6835</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6834" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6833" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6833</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6835" BrowseName="EURange" ParentNodeId="ns=1;i=6833" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6833</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6836" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5054" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6837</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6838</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6837" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6836" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6836</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6838" BrowseName="EURange" ParentNodeId="ns=1;i=6836" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6836</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6839" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5054" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6840</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6841</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5054</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6840" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6839" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6839</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6841" BrowseName="EURange" ParentNodeId="ns=1;i=6839" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6839</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5055" BrowseName="1:CrossAxisRight" ParentNodeId="ns=1;i=5052">
    <DisplayName>CrossAxisRight</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6842</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6844</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6847</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6848</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6851</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6854</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6857</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6860</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7066</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6863</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6866</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6869</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6874</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6905</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6842" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5055" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6904</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6843</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6904" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6842" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6842</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6843" BrowseName="EURange" ParentNodeId="ns=1;i=6842" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6842</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6844" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5055" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6845</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6846</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6845" BrowseName="EnumValues" ParentNodeId="ns=1;i=6844" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6844</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6846" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6844" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6844</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6847" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5055" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5055</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6848" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5055" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6849</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6850</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6849" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6848" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6848</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6850" BrowseName="EURange" ParentNodeId="ns=1;i=6848" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6848</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6851" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5055" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6852</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6853</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6852" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6851" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6851</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6853" BrowseName="EURange" ParentNodeId="ns=1;i=6851" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6851</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6854" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5055" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6855</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6856</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6855" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6854" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6854</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6856" BrowseName="EURange" ParentNodeId="ns=1;i=6854" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6854</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6857" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5055" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6858</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6859</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6858" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6857" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6857</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6859" BrowseName="EURange" ParentNodeId="ns=1;i=6857" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6857</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6860" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5055" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6861</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6862</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6861" BrowseName="EnumValues" ParentNodeId="ns=1;i=6860" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6860</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6862" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6860" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6860</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7066" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5055" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6863" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5055" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6864</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6865</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6864" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6863" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6863</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6865" BrowseName="EURange" ParentNodeId="ns=1;i=6863" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6863</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6866" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5055" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6867</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6868</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6867" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6866" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6866</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6868" BrowseName="EURange" ParentNodeId="ns=1;i=6866" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6866</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6869" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5055" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6870</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6871</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6870" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6869" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6869</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6871" BrowseName="EURange" ParentNodeId="ns=1;i=6869" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6869</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6874" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5055" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6875</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6876</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6875" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6874" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6874</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6876" BrowseName="EURange" ParentNodeId="ns=1;i=6874" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6874</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6905" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5055" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6906</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6907</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5055</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6906" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6905" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6905</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6907" BrowseName="EURange" ParentNodeId="ns=1;i=6905" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6905</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5056" BrowseName="1:Drive" ParentNodeId="ns=1;i=5052">
    <DisplayName>Drive</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5057</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1068</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5058</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5059</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5060</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5061</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5062</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5057" BrowseName="2:AdditionalMeasuringDevices" ParentNodeId="ns=1;i=5056">
    <DisplayName>AdditionalMeasuringDevices</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5056</Reference>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1065</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6551</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6551" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5057" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5057</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd"></uax:String>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5058" BrowseName="2:Energy" ParentNodeId="ns=1;i=5056">
    <DisplayName>Energy</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6963</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6965</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5056</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1063</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6967</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6969</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6963" BrowseName="2:ActualPower" ParentNodeId="ns=1;i=5058" DataType="Double">
    <DisplayName>ActualPower</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5058</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6964</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6964" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6963" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6963</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6965" BrowseName="2:ActualSpecificEnergy" ParentNodeId="ns=1;i=5058" DataType="Double">
    <DisplayName>ActualSpecificEnergy</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5058</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6966</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6966" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6965" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6965</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6967" BrowseName="2:PowerConsumption" ParentNodeId="ns=1;i=5058" DataType="Double">
    <DisplayName>PowerConsumption</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6968</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5058</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6968" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6967" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6967</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6969" BrowseName="2:PowerFactor" ParentNodeId="ns=1;i=5058" DataType="Double">
    <DisplayName>PowerFactor</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5058</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5059" BrowseName="2:Maintenance" ParentNodeId="ns=1;i=5056">
    <DisplayName>Maintenance</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6970</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6971</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5056</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6974</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7044</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6552</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6977</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6970" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5059" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5059</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6971" BrowseName="2:Interval" ParentNodeId="ns=1;i=5059" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <Description>Regular interval between two maintenances</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6972</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6973</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5059</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6972" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6971" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6971</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6973" BrowseName="EURange" ParentNodeId="ns=1;i=6971" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6971</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6974" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5059" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <Description>Interval before next maintenance is due</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6975</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6976</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5059</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6975" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6974" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6974</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6976" BrowseName="EURange" ParentNodeId="ns=1;i=6974" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6974</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7044" BrowseName="2:Reset" ParentNodeId="ns=1;i=5059" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the RemainingInterval to Interval and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5059</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6552" BrowseName="2:Status" ParentNodeId="ns=1;i=5059" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5059</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6977" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5059" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <Description>How long is the component running in total</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6978</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6979</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5059</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6978" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6977" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6977</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6979" BrowseName="EURange" ParentNodeId="ns=1;i=6977" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6977</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5060" BrowseName="2:Speed" ParentNodeId="ns=1;i=5056">
    <DisplayName>Speed</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6553</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6981</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6984</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6985</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6989</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6992</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6995</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6998</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7047</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7048</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7067</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7070</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7073</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7077</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6553" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5060" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6980</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6554</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6980" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6553" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6553</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6554" BrowseName="EURange" ParentNodeId="ns=1;i=6553" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6553</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6981" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5060" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6982</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6983</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6982" BrowseName="EnumValues" ParentNodeId="ns=1;i=6981" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6981</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6983" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6981" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6981</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6984" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5060" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5060</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6985" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5060" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6986</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6988</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6986" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6985" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6985</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6988" BrowseName="EURange" ParentNodeId="ns=1;i=6985" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6985</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6989" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5060" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6990</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6991</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6990" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6989" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6989</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6991" BrowseName="EURange" ParentNodeId="ns=1;i=6989" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6989</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6992" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5060" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6993</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6994</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6993" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6992" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6992</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6994" BrowseName="EURange" ParentNodeId="ns=1;i=6992" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6992</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6995" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5060" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6996</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6997</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6996" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6995" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6995</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6997" BrowseName="EURange" ParentNodeId="ns=1;i=6995" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6995</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6998" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5060" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6999</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7000</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6999" BrowseName="EnumValues" ParentNodeId="ns=1;i=6998" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6998</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7000" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6998" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6998</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7047" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5060" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=7048" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5060" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7063</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7064</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7063" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7048" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7048</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7064" BrowseName="EURange" ParentNodeId="ns=1;i=7048" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7048</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7067" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5060" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7068</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7069</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7068" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7067" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7067</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7069" BrowseName="EURange" ParentNodeId="ns=1;i=7067" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7067</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7070" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5060" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7071</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7072</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7071" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7070" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7070</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7072" BrowseName="EURange" ParentNodeId="ns=1;i=7070" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7070</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7073" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5060" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7075</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7076</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7075" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7073" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7073</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7076" BrowseName="EURange" ParentNodeId="ns=1;i=7073" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7073</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7077" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5060" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7078</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7081</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5060</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7078" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7077" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7077</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7081" BrowseName="EURange" ParentNodeId="ns=1;i=7077" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7077</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5061" BrowseName="2:StartDrive" ParentNodeId="ns=1;i=5056">
    <DisplayName>StartDrive</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7082</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1023</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7083</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6555</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7084</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=7082" BrowseName="2:StartBlockedByClient" ParentNodeId="ns=1;i=5061" DataType="Boolean" AccessLevel="3">
    <DisplayName>StartBlockedByClient</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5061</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7083" BrowseName="2:StartRequest" ParentNodeId="ns=1;i=5061" MethodDeclarationId="ns=2;i=7051">
    <DisplayName>StartRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5061</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6555" BrowseName="2:Status" ParentNodeId="ns=1;i=5061" DataType="StartEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5061</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7084" BrowseName="2:StopRequest" ParentNodeId="ns=1;i=5061" MethodDeclarationId="ns=2;i=7056">
    <DisplayName>StopRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5061</Reference>
    </References>
  </UAMethod>
  <UAObject NodeId="ns=1;i=5062" BrowseName="2:Torque" ParentNodeId="ns=1;i=5056">
    <DisplayName>Torque</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6556</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7086</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7089</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7090</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7093</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7096</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7099</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7102</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7105</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7106</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7109</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7112</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7115</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7118</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6556" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5062" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7085</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6557</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7085" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6556" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6556</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6557" BrowseName="EURange" ParentNodeId="ns=1;i=6556" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6556</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7086" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5062" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7087</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7088</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7087" BrowseName="EnumValues" ParentNodeId="ns=1;i=7086" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7086</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7088" BrowseName="ValueAsText" ParentNodeId="ns=1;i=7086" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7086</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7089" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5062" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5062</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7090" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5062" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7091</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7092</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7091" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7090" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7090</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7092" BrowseName="EURange" ParentNodeId="ns=1;i=7090" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7090</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7093" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5062" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7094</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7095</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7094" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7093" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7093</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7095" BrowseName="EURange" ParentNodeId="ns=1;i=7093" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7093</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7096" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5062" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7097</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7098</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7097" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7096" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7096</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7098" BrowseName="EURange" ParentNodeId="ns=1;i=7096" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7096</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7099" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5062" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7100</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7101</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7100" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7099" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7099</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7101" BrowseName="EURange" ParentNodeId="ns=1;i=7099" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7099</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7102" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5062" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=7103</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7104</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7103" BrowseName="EnumValues" ParentNodeId="ns=1;i=7102" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7102</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7104" BrowseName="ValueAsText" ParentNodeId="ns=1;i=7102" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7102</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7105" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5062" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=7106" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5062" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7107</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7108</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7107" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7106" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7106</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7108" BrowseName="EURange" ParentNodeId="ns=1;i=7106" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7106</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7109" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5062" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7110</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7111</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7110" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7109" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7109</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7111" BrowseName="EURange" ParentNodeId="ns=1;i=7109" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7109</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7112" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5062" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7113</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7114</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7113" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7112" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7112</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7114" BrowseName="EURange" ParentNodeId="ns=1;i=7112" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7112</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7115" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5062" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7116</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7117</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7116" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7115" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7115</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7117" BrowseName="EURange" ParentNodeId="ns=1;i=7115" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7115</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7118" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5062" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7119</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7120</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5062</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7119" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=7118" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7118</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7120" BrowseName="EURange" ParentNodeId="ns=1;i=7118" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7118</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7074" BrowseName="1:Id" ParentNodeId="ns=1;i=5052" DataType="String">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7079" BrowseName="1:MasterRollId" ParentNodeId="ns=1;i=5052" DataType="String">
    <DisplayName>MasterRollId</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=7080" BrowseName="1:Name" ParentNodeId="ns=1;i=5052" DataType="LocalizedText">
    <DisplayName>Name</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5040" BrowseName="1:PeripheralDevices" ParentNodeId="ns=1;i=5052">
    <DisplayName>PeripheralDevices</DisplayName>
    <References>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=7305</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1008</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=7305" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5040" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5042" BrowseName="1:RollBending" ParentNodeId="ns=1;i=5052">
    <DisplayName>RollBending</DisplayName>
    <References>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6563</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1007</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6563" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5042" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5068" BrowseName="1:Temperature" ParentNodeId="ns=1;i=5052">
    <DisplayName>Temperature</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6606</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6608</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6611</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5050</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6612</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6614</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5051</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1016</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6617</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6618</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6619</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6621</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5053</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6624</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6626</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6628</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6631</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6632</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6634</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6636</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7052</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6637</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6640</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6644</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5063</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5052</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6647</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6649</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6606" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5068" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6607</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6607" BrowseName="EURange" ParentNodeId="ns=1;i=6606" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6606</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6608" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5068" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6609</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6610</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6609" BrowseName="EnumValues" ParentNodeId="ns=1;i=6608" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6608</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6610" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6608" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6608</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6611" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5068" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5050" BrowseName="2:ClosedLoopControl" ParentNodeId="ns=1;i=5068">
    <DisplayName>ClosedLoopControl</DisplayName>
    <Description>With this type the client can do settings for the closed loop control on the device for a parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6612" BrowseName="1:ControllerOutput" ParentNodeId="ns=1;i=5068" DataType="Double">
    <DisplayName>ControllerOutput</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6613</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6613" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6612" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6612</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6614" BrowseName="2:ControlMode" ParentNodeId="ns=1;i=5068" DataType="ControlModeEnumeration">
    <DisplayName>ControlMode</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5051" BrowseName="1:ElectricalCurrent" ParentNodeId="ns=1;i=5068">
    <DisplayName>ElectricalCurrent</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6615</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6615" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5051" DataType="Double" AccessLevel="5">
    <DisplayName>ActualValue</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5051</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6616</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6616" BrowseName="EURange" ParentNodeId="ns=1;i=6615" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6615</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6617" BrowseName="2:Id" ParentNodeId="ns=1;i=5068" DataType="String">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd"></uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6618" BrowseName="2:IsPresent" ParentNodeId="ns=1;i=5068" DataType="Boolean">
    <DisplayName>IsPresent</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6619" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5068" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6620</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6620" BrowseName="EURange" ParentNodeId="ns=1;i=6619" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6619</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6621" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5068" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6622</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6622" BrowseName="EURange" ParentNodeId="ns=1;i=6621" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6621</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5053" BrowseName="2:Maintenance" ParentNodeId="ns=1;i=5068">
    <DisplayName>Maintenance</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7051</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6623</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
    </References>
  </UAObject>
  <UAMethod NodeId="ns=1;i=7051" BrowseName="2:Reset" ParentNodeId="ns=1;i=5053" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the CurrentInterval to 0 and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5053</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6623" BrowseName="2:Status" ParentNodeId="ns=1;i=5053" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5053</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6624" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5068" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6625</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6625" BrowseName="EURange" ParentNodeId="ns=1;i=6624" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6624</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6626" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5068" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6627</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6627" BrowseName="EURange" ParentNodeId="ns=1;i=6626" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6626</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6628" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5068" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6629</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6630</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6629" BrowseName="EnumValues" ParentNodeId="ns=1;i=6628" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6628</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6630" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6628" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6628</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6631" BrowseName="2:Name" ParentNodeId="ns=1;i=5068" DataType="LocalizedText">
    <DisplayName>Name</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:LocalizedText xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd" />
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6632" BrowseName="1:NominalCoolingPower" ParentNodeId="ns=1;i=5068" DataType="Double">
    <DisplayName>NominalCoolingPower</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6633</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6633" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6632" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6632</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6634" BrowseName="1:NominalHeatingPower" ParentNodeId="ns=1;i=5068" DataType="Double">
    <DisplayName>NominalHeatingPower</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6635</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6635" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6634" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6634</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6636" BrowseName="2:Position" ParentNodeId="ns=1;i=5068" DataType="String">
    <DisplayName>Position</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5068</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7052" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5068" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6637" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5068" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6639</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6639" BrowseName="EURange" ParentNodeId="ns=1;i=6637" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6637</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6640" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5068" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6643</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6643" BrowseName="EURange" ParentNodeId="ns=1;i=6640" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6640</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6644" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5068" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6645</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6645" BrowseName="EURange" ParentNodeId="ns=1;i=6644" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6644</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5063" BrowseName="2:StartDevice" ParentNodeId="ns=1;i=5068">
    <DisplayName>StartDevice</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1023</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6646</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6646" BrowseName="2:Status" ParentNodeId="ns=1;i=5063" DataType="StartEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5063</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6647" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5068" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6648</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6648" BrowseName="EURange" ParentNodeId="ns=1;i=6647" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6647</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6649" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5068" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6650</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5068</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6650" BrowseName="EURange" ParentNodeId="ns=1;i=6649" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6649</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1005" BrowseName="1:RollType">
    <DisplayName>RollType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/9.2.1</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5032</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5033</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6638</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6641</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6642</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5030</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5046</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5031" BrowseName="1:CrossAxisLeft" ParentNodeId="ns=1;i=1005">
    <DisplayName>CrossAxisLeft</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6470</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6473</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6476</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6477</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6480</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6483</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6486</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6489</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7041</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6492</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6495</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6498</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6501</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6504</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6470" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5031" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6471</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6472</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6471" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6470" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6470</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6472" BrowseName="EURange" ParentNodeId="ns=1;i=6470" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6470</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6473" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5031" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6474</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6475</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6474" BrowseName="EnumValues" ParentNodeId="ns=1;i=6473" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6473</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6475" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6473" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6473</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6476" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5031" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6477" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5031" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6478</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6479</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6478" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6477" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6477</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6479" BrowseName="EURange" ParentNodeId="ns=1;i=6477" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6477</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6480" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5031" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6481</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6482</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6481" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6480" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6480</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6482" BrowseName="EURange" ParentNodeId="ns=1;i=6480" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6480</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6483" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5031" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6484</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6485</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6484" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6483" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6483</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6485" BrowseName="EURange" ParentNodeId="ns=1;i=6483" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6483</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6486" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5031" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6487</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6488</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6487" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6486" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6486</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6488" BrowseName="EURange" ParentNodeId="ns=1;i=6486" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6486</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6489" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5031" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6490</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6491</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6490" BrowseName="EnumValues" ParentNodeId="ns=1;i=6489" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6489</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6491" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6489" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6489</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7041" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5031" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6492" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5031" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6493</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6494</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6493" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6492" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6492</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6494" BrowseName="EURange" ParentNodeId="ns=1;i=6492" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6492</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6495" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5031" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6496</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6497</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6496" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6495" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6495</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6497" BrowseName="EURange" ParentNodeId="ns=1;i=6495" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6495</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6498" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5031" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6499</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6500</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6499" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6498" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6498</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6500" BrowseName="EURange" ParentNodeId="ns=1;i=6498" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6498</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6501" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5031" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6502</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6503</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6502" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6501" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6501</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6503" BrowseName="EURange" ParentNodeId="ns=1;i=6501" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6501</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6504" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5031" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6505</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6506</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6505" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6504" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6504</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6506" BrowseName="EURange" ParentNodeId="ns=1;i=6504" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6504</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5032" BrowseName="1:CrossAxisRight" ParentNodeId="ns=1;i=1005">
    <DisplayName>CrossAxisRight</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6507</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6510</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6513</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6514</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6517</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6520</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6523</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6526</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7042</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6529</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6532</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6535</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6538</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6541</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6507" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5032" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6508</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6509</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6508" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6507" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6507</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6509" BrowseName="EURange" ParentNodeId="ns=1;i=6507" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6507</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6510" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5032" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6511</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6512</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6511" BrowseName="EnumValues" ParentNodeId="ns=1;i=6510" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6510</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6512" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6510" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6510</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6513" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5032" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5032</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6514" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5032" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6515</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6516</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6515" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6514" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6514</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6516" BrowseName="EURange" ParentNodeId="ns=1;i=6514" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6514</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6517" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5032" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6518</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6519</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6518" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6517" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6517</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6519" BrowseName="EURange" ParentNodeId="ns=1;i=6517" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6517</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6520" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5032" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6521</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6522</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6521" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6520" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6520</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6522" BrowseName="EURange" ParentNodeId="ns=1;i=6520" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6520</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6523" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5032" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6524</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6525</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6524" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6523" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6523</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6525" BrowseName="EURange" ParentNodeId="ns=1;i=6523" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6523</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6526" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5032" DataType="UInt16">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6527</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6528</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6527" BrowseName="EnumValues" ParentNodeId="ns=1;i=6526" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6526</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6528" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6526" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6526</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7042" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5032" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6529" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5032" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6530</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6531</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6530" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6529" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6529</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6531" BrowseName="EURange" ParentNodeId="ns=1;i=6529" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6529</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6532" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5032" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6533</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6534</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6533" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6532" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6532</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6534" BrowseName="EURange" ParentNodeId="ns=1;i=6532" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6532</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6535" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5032" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6536</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6537</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6536" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6535" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6535</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6537" BrowseName="EURange" ParentNodeId="ns=1;i=6535" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6535</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6538" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5032" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6539</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6540</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6539" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6538" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6538</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6540" BrowseName="EURange" ParentNodeId="ns=1;i=6538" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6538</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6541" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5032" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6542</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6543</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6542" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6541" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6541</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6543" BrowseName="EURange" ParentNodeId="ns=1;i=6541" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6541</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5033" BrowseName="1:Drive" ParentNodeId="ns=1;i=1005">
    <DisplayName>Drive</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5034</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1068</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5035</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5036</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5037</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5038</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5039</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5034" BrowseName="2:AdditionalMeasuringDevices" ParentNodeId="ns=1;i=5033">
    <DisplayName>AdditionalMeasuringDevices</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5033</Reference>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1065</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6544</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6544" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5034" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5034</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd"></uax:String>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5035" BrowseName="2:Energy" ParentNodeId="ns=1;i=5033">
    <DisplayName>Energy</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6469</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6559</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5033</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1063</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6561</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6778</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6469" BrowseName="2:ActualPower" ParentNodeId="ns=1;i=5035" DataType="Double">
    <DisplayName>ActualPower</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5035</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6558</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6558" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6469" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6469</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6559" BrowseName="2:ActualSpecificEnergy" ParentNodeId="ns=1;i=5035" DataType="Double">
    <DisplayName>ActualSpecificEnergy</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5035</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6560</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6560" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6559" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6559</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6561" BrowseName="2:PowerConsumption" ParentNodeId="ns=1;i=5035" DataType="Double">
    <DisplayName>PowerConsumption</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6777</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5035</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6777" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6561" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6561</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6778" BrowseName="2:PowerFactor" ParentNodeId="ns=1;i=5035" DataType="Double">
    <DisplayName>PowerFactor</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5035</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5036" BrowseName="2:Maintenance" ParentNodeId="ns=1;i=5033">
    <DisplayName>Maintenance</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6779</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6780</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5033</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6782</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7043</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6545</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6784</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6779" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5036" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5036</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6780" BrowseName="2:Interval" ParentNodeId="ns=1;i=5036" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <Description>Regular interval between two maintenances</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6940</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6781</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5036</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6940" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6780" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6780</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6781" BrowseName="EURange" ParentNodeId="ns=1;i=6780" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6780</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6782" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5036" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <Description>Interval before next maintenance is due</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6941</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6783</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5036</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6941" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6782" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6782</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6783" BrowseName="EURange" ParentNodeId="ns=1;i=6782" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6782</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7043" BrowseName="2:Reset" ParentNodeId="ns=1;i=5036" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the RemainingInterval to Interval and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5036</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6545" BrowseName="2:Status" ParentNodeId="ns=1;i=5036" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5036</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6784" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5036" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <Description>How long is the component running in total</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6942</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6785</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5036</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6942" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6784" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6784</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6785" BrowseName="EURange" ParentNodeId="ns=1;i=6784" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6784</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5037" BrowseName="2:Speed" ParentNodeId="ns=1;i=5033">
    <DisplayName>Speed</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6546</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6786</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6789</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6790</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6792</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6794</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6796</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6798</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7039</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6801</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6804</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6908</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5033</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6910</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6912</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6546" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5037" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6943</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6547</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6943" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6546" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6546</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6547" BrowseName="EURange" ParentNodeId="ns=1;i=6546" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6546</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6786" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5037" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6787</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6788</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6787" BrowseName="EnumValues" ParentNodeId="ns=1;i=6786" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6786</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6788" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6786" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6786</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6789" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5037" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5037</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6790" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5037" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6944</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6791</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6944" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6790" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6790</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6791" BrowseName="EURange" ParentNodeId="ns=1;i=6790" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6790</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6792" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5037" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6945</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6793</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6945" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6792" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6792</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6793" BrowseName="EURange" ParentNodeId="ns=1;i=6792" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6792</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6794" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5037" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6946</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6795</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6946" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6794" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6794</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6795" BrowseName="EURange" ParentNodeId="ns=1;i=6794" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6794</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6796" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5037" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6947</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6797</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6947" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6796" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6796</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6797" BrowseName="EURange" ParentNodeId="ns=1;i=6796" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6796</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6798" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5037" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6799</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6800</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6799" BrowseName="EnumValues" ParentNodeId="ns=1;i=6798" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6798</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6800" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6798" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6798</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7039" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5037" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6801" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5037" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6948</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6802</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6948" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6801" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6801</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6802" BrowseName="EURange" ParentNodeId="ns=1;i=6801" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6801</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6804" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5037" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6949</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6805</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6949" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6804" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6804</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6805" BrowseName="EURange" ParentNodeId="ns=1;i=6804" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6804</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6908" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5037" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6950</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6909</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6950" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6908" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6908</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6909" BrowseName="EURange" ParentNodeId="ns=1;i=6908" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6908</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6910" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5037" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6951</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6911</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6951" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6910" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6910</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6911" BrowseName="EURange" ParentNodeId="ns=1;i=6910" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6910</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6912" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5037" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6952</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6913</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5037</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6952" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6912" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6912</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6913" BrowseName="EURange" ParentNodeId="ns=1;i=6912" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6912</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5038" BrowseName="2:StartDrive" ParentNodeId="ns=1;i=5033">
    <DisplayName>StartDrive</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6914</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1023</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5033</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7040</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6548</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7045</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6914" BrowseName="2:StartBlockedByClient" ParentNodeId="ns=1;i=5038" DataType="Boolean" AccessLevel="3">
    <DisplayName>StartBlockedByClient</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5038</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7040" BrowseName="2:StartRequest" ParentNodeId="ns=1;i=5038" MethodDeclarationId="ns=2;i=7051">
    <DisplayName>StartRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5038</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6548" BrowseName="2:Status" ParentNodeId="ns=1;i=5038" DataType="StartEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5038</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7045" BrowseName="2:StopRequest" ParentNodeId="ns=1;i=5038" MethodDeclarationId="ns=2;i=7056">
    <DisplayName>StopRequest</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5038</Reference>
    </References>
  </UAMethod>
  <UAObject NodeId="ns=1;i=5039" BrowseName="2:Torque" ParentNodeId="ns=1;i=5033">
    <DisplayName>Torque</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6549</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6915</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6918</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6919</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6921</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6923</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6925</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6927</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7046</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6930</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6932</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6934</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5033</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6936</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6938</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6549" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5039" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6953</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6550</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6953" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6549" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6549</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6550" BrowseName="EURange" ParentNodeId="ns=1;i=6549" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6549</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6915" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5039" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6916</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6917</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6916" BrowseName="EnumValues" ParentNodeId="ns=1;i=6915" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6915</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6917" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6915" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6915</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6918" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5039" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5039</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6919" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5039" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6954</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6920</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6954" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6919" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6919</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6920" BrowseName="EURange" ParentNodeId="ns=1;i=6919" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6919</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6921" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5039" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6955</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6922</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6955" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6921" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6921</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6922" BrowseName="EURange" ParentNodeId="ns=1;i=6921" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6921</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6923" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5039" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6956</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6924</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6956" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6923" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6923</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6924" BrowseName="EURange" ParentNodeId="ns=1;i=6923" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6923</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6925" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5039" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6957</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6926</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6957" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6925" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6925</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6926" BrowseName="EURange" ParentNodeId="ns=1;i=6925" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6925</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6927" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5039" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6928</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6929</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6928" BrowseName="EnumValues" ParentNodeId="ns=1;i=6927" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6927</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6929" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6927" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6927</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7046" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5039" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6930" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5039" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6958</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6931</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6958" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6930" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6930</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6931" BrowseName="EURange" ParentNodeId="ns=1;i=6930" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6930</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6932" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5039" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6959</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6933</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6959" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6932" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6932</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6933" BrowseName="EURange" ParentNodeId="ns=1;i=6932" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6932</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6934" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5039" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6960</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6935</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6960" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6934" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6934</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6935" BrowseName="EURange" ParentNodeId="ns=1;i=6934" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6934</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6936" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5039" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6961</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6937</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6961" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6936" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6936</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6937" BrowseName="EURange" ParentNodeId="ns=1;i=6936" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6936</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6938" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5039" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6962</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6939</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5039</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6962" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6938" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6938</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6939" BrowseName="EURange" ParentNodeId="ns=1;i=6938" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6938</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6638" BrowseName="1:Id" ParentNodeId="ns=1;i=1005" DataType="String">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6641" BrowseName="1:MasterRollId" ParentNodeId="ns=1;i=1005" DataType="String">
    <DisplayName>MasterRollId</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6642" BrowseName="1:Name" ParentNodeId="ns=1;i=1005" DataType="LocalizedText">
    <DisplayName>Name</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5030" BrowseName="1:PeripheralDevices" ParentNodeId="ns=1;i=1005">
    <DisplayName>PeripheralDevices</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6468</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1008</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6468" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5030" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5030</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5041" BrowseName="1:RollBending" ParentNodeId="ns=1;i=1005">
    <DisplayName>RollBending</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6562</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1007</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6562" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5041" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5046" BrowseName="1:Temperature" ParentNodeId="ns=1;i=1005">
    <DisplayName>Temperature</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6567</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6569</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6572</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5043</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6573</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6564</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5045</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1016</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6565</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6566</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6577</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6579</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5048</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6582</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6584</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6586</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6589</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6590</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6592</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6594</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7050</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6595</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6597</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6599</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5049</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6602</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6604</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6567" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5046" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6568</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6568" BrowseName="EURange" ParentNodeId="ns=1;i=6567" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6567</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6569" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5046" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6570</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6571</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6570" BrowseName="EnumValues" ParentNodeId="ns=1;i=6569" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6569</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6571" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6569" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6569</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6572" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5046" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5043" BrowseName="2:ClosedLoopControl" ParentNodeId="ns=1;i=5046">
    <DisplayName>ClosedLoopControl</DisplayName>
    <Description>With this type the client can do settings for the closed loop control on the device for a parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6573" BrowseName="1:ControllerOutput" ParentNodeId="ns=1;i=5046" DataType="Double">
    <DisplayName>ControllerOutput</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6574</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6574" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6573" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6573</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6564" BrowseName="2:ControlMode" ParentNodeId="ns=1;i=5046" DataType="ControlModeEnumeration">
    <DisplayName>ControlMode</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5045" BrowseName="1:ElectricalCurrent" ParentNodeId="ns=1;i=5046">
    <DisplayName>ElectricalCurrent</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6575</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6575" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5045" DataType="Double" AccessLevel="5">
    <DisplayName>ActualValue</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5045</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6576</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6576" BrowseName="EURange" ParentNodeId="ns=1;i=6575" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6575</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6565" BrowseName="2:Id" ParentNodeId="ns=1;i=5046" DataType="String">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd"></uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6566" BrowseName="2:IsPresent" ParentNodeId="ns=1;i=5046" DataType="Boolean">
    <DisplayName>IsPresent</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6577" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5046" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6578</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6578" BrowseName="EURange" ParentNodeId="ns=1;i=6577" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6577</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6579" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5046" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6580</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6580" BrowseName="EURange" ParentNodeId="ns=1;i=6579" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6579</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5048" BrowseName="2:Maintenance" ParentNodeId="ns=1;i=5046">
    <DisplayName>Maintenance</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7049</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6581</Reference>
    </References>
  </UAObject>
  <UAMethod NodeId="ns=1;i=7049" BrowseName="2:Reset" ParentNodeId="ns=1;i=5048" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the CurrentInterval to 0 and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5048</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6581" BrowseName="2:Status" ParentNodeId="ns=1;i=5048" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5048</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6582" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5046" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6583</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6583" BrowseName="EURange" ParentNodeId="ns=1;i=6582" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6582</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6584" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5046" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6585</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6585" BrowseName="EURange" ParentNodeId="ns=1;i=6584" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6584</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6586" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5046" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6587</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6588</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6587" BrowseName="EnumValues" ParentNodeId="ns=1;i=6586" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6586</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6588" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6586" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6586</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6589" BrowseName="2:Name" ParentNodeId="ns=1;i=5046" DataType="LocalizedText">
    <DisplayName>Name</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:LocalizedText xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd" />
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6590" BrowseName="1:NominalCoolingPower" ParentNodeId="ns=1;i=5046" DataType="Double">
    <DisplayName>NominalCoolingPower</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6591</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6591" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6590" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6590</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6592" BrowseName="1:NominalHeatingPower" ParentNodeId="ns=1;i=5046" DataType="Double">
    <DisplayName>NominalHeatingPower</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=17497</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6593</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6593" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6592" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6592</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6594" BrowseName="2:Position" ParentNodeId="ns=1;i=5046" DataType="String">
    <DisplayName>Position</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7050" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5046" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6595" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5046" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6596</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6596" BrowseName="EURange" ParentNodeId="ns=1;i=6595" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6595</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6597" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5046" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6598</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6598" BrowseName="EURange" ParentNodeId="ns=1;i=6597" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6597</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6599" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5046" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6600</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6600" BrowseName="EURange" ParentNodeId="ns=1;i=6599" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6599</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5049" BrowseName="2:StartDevice" ParentNodeId="ns=1;i=5046">
    <DisplayName>StartDevice</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1023</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6601</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6601" BrowseName="2:Status" ParentNodeId="ns=1;i=5049" DataType="StartEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5049</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6602" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5046" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6603</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6603" BrowseName="EURange" ParentNodeId="ns=1;i=6602" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6602</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6604" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5046" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6605</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6605" BrowseName="EURange" ParentNodeId="ns=1;i=6604" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6604</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1009" BrowseName="1:ExtrusionExecutingSubState_StateMachineType">
    <DisplayName>ExtrusionExecutingSubState_StateMachineType</DisplayName>
    <Category>Extrusion Device</Category>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/6.3.2</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5070</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=2771</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5080</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5078</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5079</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5072</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5077</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5071</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5069</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5067</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5070" BrowseName="1:ControlledRun" ParentNodeId="ns=1;i=1009">
    <DisplayName>ControlledRun</DisplayName>
    <Description>Component is running with controlled parameters</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6672</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2307</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5077</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5078</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5079</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5080</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6672" BrowseName="StateNumber" ParentNodeId="ns=1;i=5070" DataType="UInt32">
    <DisplayName>StateNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5070</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">2</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5080" BrowseName="1:FromControlledRunToManualRun" ParentNodeId="ns=1;i=1009">
    <DisplayName>FromControlledRunToManualRun</DisplayName>
    <Description>Transition from state ControlledRun to state ManualRun</Description>
    <References>
      <Reference ReferenceType="FromState">ns=1;i=5070</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5069</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6678</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6678" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5080" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5080</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">5</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5078" BrowseName="1:FromControlledRunToReadyToRun" ParentNodeId="ns=1;i=1009">
    <DisplayName>FromControlledRunToReadyToRun</DisplayName>
    <Description>Transition from state ControlledRun to state ReadyToRun</Description>
    <References>
      <Reference ReferenceType="FromState">ns=1;i=5070</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5067</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6676</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6676" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5078" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5078</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">3</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5079" BrowseName="1:FromManualRunToControlledRun" ParentNodeId="ns=1;i=1009">
    <DisplayName>FromManualRunToControlledRun</DisplayName>
    <Description>Transition from state ManualRun to state ControlledRun</Description>
    <References>
      <Reference ReferenceType="ToState">ns=1;i=5070</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5069</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6677</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6677" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5079" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5079</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">4</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5072" BrowseName="1:FromManualRunToReadyToRun" ParentNodeId="ns=1;i=1009">
    <DisplayName>FromManualRunToReadyToRun</DisplayName>
    <Description>Transition from state ManualRun to state ReadyToRun</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5069</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5067</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6674</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6674" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5072" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5072</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">1</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5077" BrowseName="1:FromReadyToRunToControlledRun" ParentNodeId="ns=1;i=1009">
    <DisplayName>FromReadyToRunToControlledRun</DisplayName>
    <Description>Transition from state ReadyToRun to state ControlledRun</Description>
    <References>
      <Reference ReferenceType="ToState">ns=1;i=5070</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5067</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6675</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6675" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5077" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5077</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">2</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5071" BrowseName="1:FromReadyToRunToManualRun" ParentNodeId="ns=1;i=1009">
    <DisplayName>FromReadyToRunToManualRun</DisplayName>
    <Description>Transition from state ReadyToRun to state ManualRun</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5069</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5067</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6673</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6673" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5071" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5071</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5069" BrowseName="1:ManualRun" ParentNodeId="ns=1;i=1009">
    <DisplayName>ManualRun</DisplayName>
    <Description>Component is running with manually set parameters</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6671</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2307</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5071</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5072</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5079</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5080</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6671" BrowseName="StateNumber" ParentNodeId="ns=1;i=5069" DataType="UInt32">
    <DisplayName>StateNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5069</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">1</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5067" BrowseName="1:ReadyToRun" ParentNodeId="ns=1;i=1009">
    <DisplayName>ReadyToRun</DisplayName>
    <Description>Component is not running but able to start immediately (e.g. heating is switched on, set temperatures have been reached)</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6670</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2307</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5071</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5072</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5077</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5078</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6670" BrowseName="StateNumber" ParentNodeId="ns=1;i=5067" DataType="UInt32">
    <DisplayName>StateNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5067</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1010" BrowseName="1:ExtrusionMachineryItemState_StateMachineType">
    <DisplayName>ExtrusionMachineryItemState_StateMachineType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/6.3.1</Documentation>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6017</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5092</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5093</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">ns=4;i=1002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5082</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5084</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5085</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5086</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5087</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5088</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5089</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5090</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5091</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5094</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5095</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5096</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5097</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5098</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5099</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5100</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5101</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5102</Reference>
    </References>
  </UAObjectType>
  <UAVariable NodeId="ns=1;i=6017" BrowseName="DefaultInstanceBrowseName" ParentNodeId="ns=1;i=1010" DataType="QualifiedName" AccessLevel="3">
    <DisplayName>DefaultInstanceBrowseName</DisplayName>
    <Description>The default BrowseName for instances of the type</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:QualifiedName xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:NamespaceIndex>4</uax:NamespaceIndex>
                <uax:Name>MachineryItemState</uax:Name>
            </uax:QualifiedName>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5092" BrowseName="4:Executing" ParentNodeId="ns=1;i=1010">
    <DisplayName>Executing</DisplayName>
    <Description>The machine is available &amp; functional and is actively performing an activity (pursues a purpose)</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5082</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5084</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5086</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5090</Reference>
      <Reference ReferenceType="HasSubStateMachine">ns=1;i=5093</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6692</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2307</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5096</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6692" BrowseName="StateNumber" ParentNodeId="ns=1;i=5092" DataType="UInt32">
    <DisplayName>StateNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5092</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">3</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5093" BrowseName="1:ExtrusionExecutingSubState" ParentNodeId="ns=1;i=1010">
    <DisplayName>ExtrusionExecutingSubState</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6687</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6688</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6693</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="HasSubStateMachine" IsForward="false">ns=1;i=5092</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6689</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6687" BrowseName="AvailableStates" ParentNodeId="ns=1;i=5093" DataType="NodeId" ValueRank="1" ArrayDimensions="0">
    <DisplayName>AvailableStates</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5093</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6688" BrowseName="AvailableTransitions" ParentNodeId="ns=1;i=5093" DataType="NodeId" ValueRank="1" ArrayDimensions="0">
    <DisplayName>AvailableTransitions</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5093</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6693" BrowseName="CurrentState" ParentNodeId="ns=1;i=5093" DataType="LocalizedText">
    <DisplayName>CurrentState</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5093</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2760</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6694</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6694" BrowseName="Id" ParentNodeId="ns=1;i=6693" DataType="NodeId">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6693</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6689" BrowseName="LastTransition" ParentNodeId="ns=1;i=5093" DataType="LocalizedText">
    <DisplayName>LastTransition</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2767</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6690</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5093</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6690" BrowseName="Id" ParentNodeId="ns=1;i=6689" DataType="NodeId">
    <DisplayName>Id</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6689</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5008" BrowseName="4:FromExecutingToExecuting" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromExecutingToExecuting</DisplayName>
    <Description>Transition from state Executing to state Executing</Description>
    <References>
      <Reference ReferenceType="FromState">ns=1;i=5092</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5092</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6021</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6021" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5008" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5008</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">14</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5082" BrowseName="4:FromExecutingToNotAvailable" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromExecutingToNotAvailable</DisplayName>
    <Description>Transition from state Executing to state NotAvailable</Description>
    <References>
      <Reference ReferenceType="FromState">ns=1;i=5092</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5100</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6022</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6022" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5082" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5082</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">6</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5084" BrowseName="4:FromExecutingToNotExecuting" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromExecutingToNotExecuting</DisplayName>
    <Description>Transition from state Executing to state NotExecuting</Description>
    <References>
      <Reference ReferenceType="FromState">ns=1;i=5092</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5101</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6023</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6023" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5084" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5084</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">8</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5085" BrowseName="4:FromExecutingToOutOfService" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromExecutingToOutOfService</DisplayName>
    <Description>Transition from state Executing to state OutOfService</Description>
    <References>
      <Reference ReferenceType="FromState">ns=4;i=5006</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5102</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6024</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6024" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5085" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5085</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">7</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5086" BrowseName="4:FromNotAvailableToExecuting" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromNotAvailableToExecuting</DisplayName>
    <Description>Transition from state NotAvailable to state Executing</Description>
    <References>
      <Reference ReferenceType="ToState">ns=1;i=5092</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5100</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6025</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6025" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5086" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5086</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">1</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5087" BrowseName="4:FromNotAvailableToNotAvailable" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromNotAvailableToNotAvailable</DisplayName>
    <Description>Transition from state NotAvailable to state NotAvailable</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5100</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5100</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6026</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6026" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5087" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5087</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">12</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5088" BrowseName="4:FromNotAvailableToNotExecuting" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromNotAvailableToNotExecuting</DisplayName>
    <Description>Transition from state NotAvailable to state NotExecuting</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5100</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5101</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6027</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6027" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5088" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5088</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">2</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5089" BrowseName="4:FromNotAvailableToOutOfService" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromNotAvailableToOutOfService</DisplayName>
    <Description>Transition from state NotAvailable to state OutOfService</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5100</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5102</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6028</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6028" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5089" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5089</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5090" BrowseName="4:FromNotExecutingToExecuting" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromNotExecutingToExecuting</DisplayName>
    <Description>Transition from state NotExecuting to state Executing</Description>
    <References>
      <Reference ReferenceType="ToState">ns=1;i=5092</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5101</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6029</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6029" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5090" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5090</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">11</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5091" BrowseName="4:FromNotExecutingToNotAvailable" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromNotExecutingToNotAvailable</DisplayName>
    <Description>Transition from state NotExecuting to state NotAvailable</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5100</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5101</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6030</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6030" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5091" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5091</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">9</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5094" BrowseName="4:FromNotExecutingToNotExecuting" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromNotExecutingToNotExecuting</DisplayName>
    <Description>Transition from state NotExecuting to state NotExecuting</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5101</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5101</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6038</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6038" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5094" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5094</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">15</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5095" BrowseName="4:FromNotExecutingToOutOfService" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromNotExecutingToOutOfService</DisplayName>
    <Description>Transition from state NotExecuting to state OutOfService</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5101</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5102</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6099</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6099" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5095" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5095</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">10</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5096" BrowseName="4:FromOutOfServiceToExecuting" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromOutOfServiceToExecuting</DisplayName>
    <Description>Transition from state OutOfService to state Executing</Description>
    <References>
      <Reference ReferenceType="ToState">ns=1;i=5092</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5102</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6175</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6175" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5096" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5096</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">4</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5097" BrowseName="4:FromOutOfServiceToNotAvailable" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromOutOfServiceToNotAvailable</DisplayName>
    <Description>Transition from state OutOfService to state NotAvailable</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5100</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5102</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6202</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6202" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5097" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5097</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">3</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5098" BrowseName="4:FromOutOfServiceToNotExecuting" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromOutOfServiceToNotExecuting</DisplayName>
    <Description>Transition from state OutOfService to state NotExecuting</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5101</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5102</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6203</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6203" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5098" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5098</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">5</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5099" BrowseName="4:FromOutOfServiceToOutOfService" ParentNodeId="ns=1;i=1010">
    <DisplayName>FromOutOfServiceToOutOfService</DisplayName>
    <Description>Transition from state OutOfService to state OutOfService</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="FromState">ns=1;i=5102</Reference>
      <Reference ReferenceType="ToState">ns=1;i=5102</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6204</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2310</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6204" BrowseName="TransitionNumber" ParentNodeId="ns=1;i=5099" DataType="UInt32">
    <DisplayName>TransitionNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5099</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">13</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5100" BrowseName="4:NotAvailable" ParentNodeId="ns=1;i=1010">
    <DisplayName>NotAvailable</DisplayName>
    <Description>The machine is not available and does not perform any activity (e.g., switched off, in energy saving mode)</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5082</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5086</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5087</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5087</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5088</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5089</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5091</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5097</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6205</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2307</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6205" BrowseName="StateNumber" ParentNodeId="ns=1;i=5100" DataType="UInt32">
    <DisplayName>StateNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5100</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5101" BrowseName="4:NotExecuting" ParentNodeId="ns=1;i=1010">
    <DisplayName>NotExecuting</DisplayName>
    <Description>The machine is available &amp; functional and does not perform any activity. It waits for an action from outside to start or restart an activity</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5084</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5088</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5090</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5091</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5094</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5094</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5095</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5098</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6703</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2307</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6703" BrowseName="StateNumber" ParentNodeId="ns=1;i=5101" DataType="UInt32">
    <DisplayName>StateNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5101</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">2</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5102" BrowseName="4:OutOfService" ParentNodeId="ns=1;i=1010">
    <DisplayName>OutOfService</DisplayName>
    <Description>The machine is not functional and does not perform any activity (e.g., error, blocked)</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5085</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5089</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5095</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5096</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5097</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5098</Reference>
      <Reference ReferenceType="FromState" IsForward="false">ns=1;i=5099</Reference>
      <Reference ReferenceType="ToState" IsForward="false">ns=1;i=5099</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6704</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2307</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6704" BrowseName="StateNumber" ParentNodeId="ns=1;i=5102" DataType="UInt32">
    <DisplayName>StateNumber</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5102</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">1</uax:UInt32>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5025" BrowseName="1:http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/GeneralTypes/" SymbolicName="http___opcfoundation_org_UA_PlasticsRubber_Extrusion_v2_GeneralTypes_">
    <DisplayName>http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/GeneralTypes/</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v105/PlasticsRubber/Extrusion/GeneralTypes/v200/docs/11.1</Documentation>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6059</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11616</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">i=11715</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6060</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6061</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6090</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6091</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6092</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6093</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6059" BrowseName="IsNamespaceSubset" ParentNodeId="ns=1;i=5025" DataType="Boolean">
    <DisplayName>IsNamespaceSubset</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5025</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6060" BrowseName="NamespacePublicationDate" ParentNodeId="ns=1;i=5025" DataType="DateTime">
    <DisplayName>NamespacePublicationDate</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5025</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:DateTime xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">2022-05-01T00:00:00Z</uax:DateTime>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6061" BrowseName="NamespaceUri" ParentNodeId="ns=1;i=5025" DataType="String">
    <DisplayName>NamespaceUri</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5025</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">http://opcfoundation.org/UA/PlasticsRubber/Extrusion_v2/GeneralTypes/</uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6090" BrowseName="NamespaceVersion" ParentNodeId="ns=1;i=5025" DataType="String">
    <DisplayName>NamespaceVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5025</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">2.00</uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6091" BrowseName="StaticNodeIdTypes" ParentNodeId="ns=1;i=5025" DataType="IdType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>StaticNodeIdTypes</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5025</Reference>
    </References>
    <Value>
      <uax:ListOfInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
                <uax:Int32>0</uax:Int32>
            </uax:ListOfInt32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6092" BrowseName="StaticNumericNodeIdRange" ParentNodeId="ns=1;i=5025" DataType="NumericRange" ValueRank="1" ArrayDimensions="0">
    <DisplayName>StaticNumericNodeIdRange</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5025</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6093" BrowseName="StaticStringNodeIdPattern" ParentNodeId="ns=1;i=5025" DataType="String">
    <DisplayName>StaticStringNodeIdPattern</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5025</Reference>
    </References>
  </UAVariable>
</UANodeSet>
