<?xml version="1.0" encoding="utf-8" ?>
<!--
 * Copyright (c) 2005-2021 The OPC Foundation, Inc. All rights reserved.
 *
 * OPC Foundation MIT License 1.00
 * 
 * Permission is hereby granted, free of charge, to any person
 * obtaining a copy of this software and associated documentation
 * files (the "Software"), to deal in the Software without
 * restriction, including without limitation the rights to use,
 * copy, modify, merge, publish, distribute, sublicense, and/or sell
 * copies of the Software, and to permit persons to whom the
 * Software is furnished to do so, subject to the following
 * conditions:
 * 
 * The above copyright notice and this permission notice shall be
 * included in all copies or substantial portions of the Software.
 * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
 * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
 * OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
 * NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
 * HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
 * WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
 * FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
 * OTHER DEALINGS IN THE SOFTWARE.
 *
 * The complete license agreement can be found here:
 * http://opcfoundation.org/License/MIT/1.00/
-->

<UANodeSet xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://opcfoundation.org/UA/2011/03/UANodeSet.xsd">
  <NamespaceUris>
    <Uri>http://opcfoundation.org/UA/PlasticsRubber/HotRunner/</Uri>
    <Uri>http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/</Uri>
    <Uri>http://opcfoundation.org/UA/DI/</Uri>
  </NamespaceUris>
  <Models>
    <Model ModelUri="http://opcfoundation.org/UA/PlasticsRubber/HotRunner/" Version="1.00" PublicationDate="2021-05-10T12:00:00Z">
      <RequiredModel ModelUri="http://opcfoundation.org/UA/" Version="1.04.7" PublicationDate="2020-07-15T00:00:00Z" />
      <RequiredModel ModelUri="http://opcfoundation.org/UA/DI/" Version="1.02.2" PublicationDate="2020-06-02T00:00:00Z" />
      <RequiredModel ModelUri="http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/" Version="1.03" PublicationDate="2021-05-10T12:00:00Z" />
    </Model>
  </Models>
  <Aliases>
    <Alias Alias="Boolean">i=1</Alias>
    <Alias Alias="Byte">i=3</Alias>
    <Alias Alias="UInt16">i=5</Alias>
    <Alias Alias="Int32">i=6</Alias>
    <Alias Alias="UInt32">i=7</Alias>
    <Alias Alias="Double">i=11</Alias>
    <Alias Alias="String">i=12</Alias>
    <Alias Alias="DateTime">i=13</Alias>
    <Alias Alias="ByteString">i=15</Alias>
    <Alias Alias="LocalizedText">i=21</Alias>
    <Alias Alias="HasModellingRule">i=37</Alias>
    <Alias Alias="HasEncoding">i=38</Alias>
    <Alias Alias="HasDescription">i=39</Alias>
    <Alias Alias="HasTypeDefinition">i=40</Alias>
    <Alias Alias="GeneratesEvent">i=41</Alias>
    <Alias Alias="HasSubtype">i=45</Alias>
    <Alias Alias="HasProperty">i=46</Alias>
    <Alias Alias="HasComponent">i=47</Alias>
    <Alias Alias="IdType">i=256</Alias>
    <Alias Alias="Duration">i=290</Alias>
    <Alias Alias="NumericRange">i=291</Alias>
    <Alias Alias="LocaleId">i=295</Alias>
    <Alias Alias="Argument">i=296</Alias>
    <Alias Alias="Range">i=884</Alias>
    <Alias Alias="EUInformation">i=887</Alias>
    <Alias Alias="EnumValueType">i=7594</Alias>
    <Alias Alias="TimeZoneDataType">i=8912</Alias>
    <Alias Alias="ClassifiedActiveErrorDataType">ns=2;i=3003</Alias>
    <Alias Alias="MaintenanceStatusEnumeration">ns=2;i=3013</Alias>
    <Alias Alias="PageEntryDataType">ns=2;i=3014</Alias>
    <Alias Alias="PIDParametersDataType">ns=2;i=3023</Alias>
    <Alias Alias="DiagnosticsStatusEnumeration">ns=2;i=3027</Alias>
    <Alias Alias="ControllerTypeEnumeration">ns=1;i=3002</Alias>
    <Alias Alias="TimeMethodPIDParametersDataType">ns=1;i=3005</Alias>
  </Aliases>
  <Extensions>
    <Extension>
      <ua:ModelInfo Tool="UaModeler" Hash="FnytYtAgC40ytu/O6u6rLA==" Version="1.6.5" xmlns:ua="http://unifiedautomation.com/Configuration/NodeSet.xsd" />
    </Extension>
  </Extensions>
  <UADataType NodeId="ns=1;i=3002" BrowseName="1:ControllerTypeEnumeration">
    <DisplayName>ControllerTypeEnumeration</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/15.3</Documentation>
    <References>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=29</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6016</Reference>
    </References>
    <Definition Name="1:ControllerTypeEnumeration">
      <Field Name="CLOSED_LOOP_CONTROL" Value="0" />
      <Field Name="MANUAL" Value="1" />
      <Field Name="SYNCHRONOUS_ZONE" Value="2" />
      <Field Name="CASCADE" Value="3" />
      <Field Name="COOL_ZONE" Value="4" />
      <Field Name="MEASURING_ZONE" Value="5" />
      <Field Name="NOT_USED" Value="6" />
    </Definition>
  </UADataType>
  <UAVariable NodeId="ns=1;i=6016" BrowseName="EnumStrings" ParentNodeId="ns=1;i=3002" DataType="LocalizedText" ValueRank="1" ArrayDimensions="7">
    <DisplayName>EnumStrings</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=3002</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:ListOfLocalizedText xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:LocalizedText>
          <uax:Text>CLOSED_LOOP_CONTROL</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>MANUAL</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>SYNCHRONOUS_ZONE</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>CASCADE</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>COOL_ZONE</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>MEASURING_ZONE</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>NOT_USED</uax:Text>
        </uax:LocalizedText>
      </uax:ListOfLocalizedText>
    </Value>
  </UAVariable>
  <UADataType NodeId="ns=1;i=3003" BrowseName="1:ZoneStatusEnumeration">
    <DisplayName>ZoneStatusEnumeration</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6050</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=29</Reference>
    </References>
    <Definition Name="1:ZoneStatusEnumeration">
      <Field Name="OTHER" Value="0" />
      <Field Name="GOOD" Value="1" />
      <Field Name="SENSOR_FAULT" Value="2" />
      <Field Name="TEMPERATURE_SENSOR_BROKEN" Value="3" />
      <Field Name="TEMPERATURE_SENSOR_REVERSED" Value="4" />
      <Field Name="POWER_UNIT_FAILED" Value="5" />
      <Field Name="HEATING_OUTPUT_TO_LOW" Value="6" />
      <Field Name="ERROR" Value="7" />
      <Field Name="WARNING" Value="8" />
      <Field Name="LEAKAGE_DETECTED" Value="9" />
    </Definition>
  </UADataType>
  <UAVariable NodeId="ns=1;i=6050" BrowseName="EnumStrings" ParentNodeId="ns=1;i=3003" DataType="LocalizedText" ValueRank="1" ArrayDimensions="10">
    <DisplayName>EnumStrings</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=3003</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:ListOfLocalizedText xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:LocalizedText>
          <uax:Text>OTHER</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>GOOD</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>SENSOR_FAULT</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>TEMPERATURE_SENSOR_BROKEN</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>TEMPERATURE_SENSOR_REVERSED</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>POWER_UNIT_FAILED</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>HEATING_OUTPUT_TO_LOW</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>ERROR</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>WARNING</uax:Text>
        </uax:LocalizedText>
        <uax:LocalizedText>
          <uax:Text>LEAKAGE_DETECTED</uax:Text>
        </uax:LocalizedText>
      </uax:ListOfLocalizedText>
    </Value>
  </UAVariable>
  <UADataType NodeId="ns=1;i=3005" BrowseName="1:TimeMethodPIDParametersDataType">
    <DisplayName>TimeMethodPIDParametersDataType</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/14</Documentation>
    <References>
      <Reference ReferenceType="HasEncoding">ns=1;i=5037</Reference>
      <Reference ReferenceType="HasEncoding">ns=1;i=5039</Reference>
      <Reference ReferenceType="HasEncoding">ns=1;i=5038</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=22</Reference>
    </References>
    <Definition Name="1:TimeMethodPIDParametersDataType">
      <Field Name="Xp" DataType="Double">
        <Description>proportional band</Description>
      </Field>
      <Field Name="Tn" DataType="Double">
        <Description>reset time</Description>
      </Field>
      <Field Name="Tv" DataType="Double">
        <Description>derivative time</Description>
      </Field>
      <Field Name="Ts" DataType="Double">
        <Description>sample time</Description>
      </Field>
    </Definition>
  </UADataType>
  <UAVariable NodeId="ns=1;i=6040" BrowseName="1:TimeMethodPIDParametersDataType" ParentNodeId="ns=1;i=6017" DataType="String">
    <DisplayName>TimeMethodPIDParametersDataType</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=69</Reference>
      <Reference ReferenceType="HasDescription" IsForward="false">ns=1;i=5037</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=6017</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">TimeMethodPIDParametersDataType</uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6093" BrowseName="1:TimeMethodPIDParametersDataType" ParentNodeId="ns=1;i=6019" DataType="String">
    <DisplayName>TimeMethodPIDParametersDataType</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=69</Reference>
      <Reference ReferenceType="HasDescription" IsForward="false">ns=1;i=5038</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=6019</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">//xs:element[@name='TimeMethodPIDParametersDataType']</uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6017" BrowseName="1:OPC40082_2" SymbolicName="OPC40082_2_BinarySchema" DataType="ByteString">
    <DisplayName>OPC40082_2</DisplayName>
    <Description>Collects the data type descriptions of http://opcfoundation.org/UA/PlasticsRubber/HotRunner/</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=72</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6018</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">i=93</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6040</Reference>
    </References>
    <Value>
      <uax:ByteString xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">PG9wYzpUeXBlRGljdGlvbmFyeSB4bWxuczp4c2k9Imh0dHA6Ly93d3cudzMub3JnLzIwMDEvWE1MU2NoZ
        W1hLWluc3RhbmNlIiB4bWxuczp0bnM9Imh0dHA6Ly9vcGNmb3VuZGF0aW9uLm9yZy9VQS9Qb
        GFzdGljc1J1YmJlci9Ib3RSdW5uZXIvIiBEZWZhdWx0Qnl0ZU9yZGVyPSJMaXR0bGVFbmRpY
        W4iIHhtbG5zOm9wYz0iaHR0cDovL29wY2ZvdW5kYXRpb24ub3JnL0JpbmFyeVNjaGVtYS8iI
        HhtbG5zOnVhPSJodHRwOi8vb3BjZm91bmRhdGlvbi5vcmcvVUEvIiBUYXJnZXROYW1lc3BhY
        2U9Imh0dHA6Ly9vcGNmb3VuZGF0aW9uLm9yZy9VQS9QbGFzdGljc1J1YmJlci9Ib3RSdW5uZ
        XIvIj4KIDxvcGM6SW1wb3J0IE5hbWVzcGFjZT0iaHR0cDovL29wY2ZvdW5kYXRpb24ub3JnL
        1VBLyIvPgogPG9wYzpTdHJ1Y3R1cmVkVHlwZSBCYXNlVHlwZT0idWE6RXh0ZW5zaW9uT2JqZ
        WN0IiBOYW1lPSJUaW1lTWV0aG9kUElEUGFyYW1ldGVyc0RhdGFUeXBlIj4KICA8b3BjOkZpZ
        WxkIFR5cGVOYW1lPSJvcGM6RG91YmxlIiBOYW1lPSJYcCIvPgogIDxvcGM6RmllbGQgVHlwZ
        U5hbWU9Im9wYzpEb3VibGUiIE5hbWU9IlRuIi8+CiAgPG9wYzpGaWVsZCBUeXBlTmFtZT0ib
        3BjOkRvdWJsZSIgTmFtZT0iVHYiLz4KICA8b3BjOkZpZWxkIFR5cGVOYW1lPSJvcGM6RG91Y
        mxlIiBOYW1lPSJUcyIvPgogPC9vcGM6U3RydWN0dXJlZFR5cGU+CiA8b3BjOkVudW1lcmF0Z
        WRUeXBlIExlbmd0aEluQml0cz0iMzIiIE5hbWU9IkNvbnRyb2xsZXJUeXBlRW51bWVyYXRpb
        24iPgogIDxvcGM6RW51bWVyYXRlZFZhbHVlIE5hbWU9IkNMT1NFRF9MT09QX0NPTlRST0wiI
        FZhbHVlPSIwIi8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iTUFOVUFMIiBWYWx1Z
        T0iMSIvPgogIDxvcGM6RW51bWVyYXRlZFZhbHVlIE5hbWU9IlNZTkNIUk9OT1VTX1pPTkUiI
        FZhbHVlPSIyIi8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iQ0FTQ0FERSIgVmFsd
        WU9IjMiLz4KICA8b3BjOkVudW1lcmF0ZWRWYWx1ZSBOYW1lPSJDT09MX1pPTkUiIFZhbHVlP
        SI0Ii8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iTUVBU1VSSU5HX1pPTkUiIFZhb
        HVlPSI1Ii8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iTk9UX1VTRUQiIFZhbHVlP
        SI2Ii8+CiA8L29wYzpFbnVtZXJhdGVkVHlwZT4KIDxvcGM6RW51bWVyYXRlZFR5cGUgTGVuZ
        3RoSW5CaXRzPSIzMiIgTmFtZT0iWm9uZVN0YXR1c0VudW1lcmF0aW9uIj4KICA8b3BjOkVud
        W1lcmF0ZWRWYWx1ZSBOYW1lPSJPVEhFUiIgVmFsdWU9IjAiLz4KICA8b3BjOkVudW1lcmF0Z
        WRWYWx1ZSBOYW1lPSJHT09EIiBWYWx1ZT0iMSIvPgogIDxvcGM6RW51bWVyYXRlZFZhbHVlI
        E5hbWU9IlNFTlNPUl9GQVVMVCIgVmFsdWU9IjIiLz4KICA8b3BjOkVudW1lcmF0ZWRWYWx1Z
        SBOYW1lPSJURU1QRVJBVFVSRV9TRU5TT1JfQlJPS0VOIiBWYWx1ZT0iMyIvPgogIDxvcGM6R
        W51bWVyYXRlZFZhbHVlIE5hbWU9IlRFTVBFUkFUVVJFX1NFTlNPUl9SRVZFUlNFRCIgVmFsd
        WU9IjQiLz4KICA8b3BjOkVudW1lcmF0ZWRWYWx1ZSBOYW1lPSJQT1dFUl9VTklUX0ZBSUxFR
        CIgVmFsdWU9IjUiLz4KICA8b3BjOkVudW1lcmF0ZWRWYWx1ZSBOYW1lPSJIRUFUSU5HX09VV
        FBVVF9UT19MT1ciIFZhbHVlPSI2Ii8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iR
        VJST1IiIFZhbHVlPSI3Ii8+CiAgPG9wYzpFbnVtZXJhdGVkVmFsdWUgTmFtZT0iV0FSTklOR
        yIgVmFsdWU9IjgiLz4KICA8b3BjOkVudW1lcmF0ZWRWYWx1ZSBOYW1lPSJMRUFLQUdFX0RFV
        EVDVEVEIiBWYWx1ZT0iOSIvPgogPC9vcGM6RW51bWVyYXRlZFR5cGU+Cjwvb3BjOlR5cGVEa
        WN0aW9uYXJ5Pgo=</uax:ByteString>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6018" BrowseName="NamespaceUri" ParentNodeId="ns=1;i=6017" DataType="String">
    <DisplayName>NamespaceUri</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6017</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">http://opcfoundation.org/UA/PlasticsRubber/HotRunner/</uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6019" BrowseName="1:OPC40082_2" SymbolicName="OPC40082_2_XmlSchema" DataType="ByteString">
    <DisplayName>OPC40082_2</DisplayName>
    <Description>Collects the data type descriptions of http://opcfoundation.org/UA/PlasticsRubber/HotRunner/</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=72</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6020</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">i=92</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6093</Reference>
    </References>
    <Value>
      <uax:ByteString xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">PHhzOnNjaGVtYSBlbGVtZW50Rm9ybURlZmF1bHQ9InF1YWxpZmllZCIgdGFyZ2V0TmFtZXNwYWNlPSJod
        HRwOi8vb3BjZm91bmRhdGlvbi5vcmcvVUEvUGxhc3RpY3NSdWJiZXIvSG90UnVubmVyL1R5c
        GVzLnhzZCIgeG1sbnM6dG5zPSJodHRwOi8vb3BjZm91bmRhdGlvbi5vcmcvVUEvUGxhc3RpY
        3NSdWJiZXIvSG90UnVubmVyL1R5cGVzLnhzZCIgeG1sbnM6dWE9Imh0dHA6Ly9vcGNmb3VuZ
        GF0aW9uLm9yZy9VQS8yMDA4LzAyL1R5cGVzLnhzZCIgeG1sbnM6eHM9Imh0dHA6Ly93d3cud
        zMub3JnLzIwMDEvWE1MU2NoZW1hIj4KIDx4czppbXBvcnQgbmFtZXNwYWNlPSJodHRwOi8vb
        3BjZm91bmRhdGlvbi5vcmcvVUEvMjAwOC8wMi9UeXBlcy54c2QiLz4KIDx4czpzaW1wbGVUe
        XBlIG5hbWU9IkNvbnRyb2xsZXJUeXBlRW51bWVyYXRpb24iPgogIDx4czpyZXN0cmljdGlvb
        iBiYXNlPSJ4czpzdHJpbmciPgogICA8eHM6ZW51bWVyYXRpb24gdmFsdWU9IkNMT1NFRF9MT
        09QX0NPTlRST0xfMCIvPgogICA8eHM6ZW51bWVyYXRpb24gdmFsdWU9Ik1BTlVBTF8xIi8+C
        iAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iU1lOQ0hST05PVVNfWk9ORV8yIi8+CiAgIDx4c
        zplbnVtZXJhdGlvbiB2YWx1ZT0iQ0FTQ0FERV8zIi8+CiAgIDx4czplbnVtZXJhdGlvbiB2Y
        Wx1ZT0iQ09PTF9aT05FXzQiLz4KICAgPHhzOmVudW1lcmF0aW9uIHZhbHVlPSJNRUFTVVJJT
        kdfWk9ORV81Ii8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iTk9UX1VTRURfNiIvPgogI
        DwveHM6cmVzdHJpY3Rpb24+CiA8L3hzOnNpbXBsZVR5cGU+CiA8eHM6ZWxlbWVudCB0eXBlP
        SJ0bnM6Q29udHJvbGxlclR5cGVFbnVtZXJhdGlvbiIgbmFtZT0iQ29udHJvbGxlclR5cGVFb
        nVtZXJhdGlvbiIvPgogPHhzOmNvbXBsZXhUeXBlIG5hbWU9Ikxpc3RPZkNvbnRyb2xsZXJUe
        XBlRW51bWVyYXRpb24iPgogIDx4czpzZXF1ZW5jZT4KICAgPHhzOmVsZW1lbnQgbWluT2Njd
        XJzPSIwIiBtYXhPY2N1cnM9InVuYm91bmRlZCIgdHlwZT0idG5zOkNvbnRyb2xsZXJUeXBlR
        W51bWVyYXRpb24iIG5hbWU9IkNvbnRyb2xsZXJUeXBlRW51bWVyYXRpb24iIG5pbGxhYmxlP
        SJ0cnVlIi8+CiAgPC94czpzZXF1ZW5jZT4KIDwveHM6Y29tcGxleFR5cGU+CiA8eHM6ZWxlb
        WVudCB0eXBlPSJ0bnM6TGlzdE9mQ29udHJvbGxlclR5cGVFbnVtZXJhdGlvbiIgbmFtZT0iT
        GlzdE9mQ29udHJvbGxlclR5cGVFbnVtZXJhdGlvbiIgbmlsbGFibGU9InRydWUiLz4KIDx4c
        zpzaW1wbGVUeXBlIG5hbWU9IlpvbmVTdGF0dXNFbnVtZXJhdGlvbiI+CiAgPHhzOnJlc3Rya
        WN0aW9uIGJhc2U9InhzOnN0cmluZyI+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iT1RIR
        VJfMCIvPgogICA8eHM6ZW51bWVyYXRpb24gdmFsdWU9IkdPT0RfMSIvPgogICA8eHM6ZW51b
        WVyYXRpb24gdmFsdWU9IlNFTlNPUl9GQVVMVF8yIi8+CiAgIDx4czplbnVtZXJhdGlvbiB2Y
        Wx1ZT0iVEVNUEVSQVRVUkVfU0VOU09SX0JST0tFTl8zIi8+CiAgIDx4czplbnVtZXJhdGlvb
        iB2YWx1ZT0iVEVNUEVSQVRVUkVfU0VOU09SX1JFVkVSU0VEXzQiLz4KICAgPHhzOmVudW1lc
        mF0aW9uIHZhbHVlPSJQT1dFUl9VTklUX0ZBSUxFRF81Ii8+CiAgIDx4czplbnVtZXJhdGlvb
        iB2YWx1ZT0iSEVBVElOR19PVVRQVVRfVE9fTE9XXzYiLz4KICAgPHhzOmVudW1lcmF0aW9uI
        HZhbHVlPSJFUlJPUl83Ii8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iV0FSTklOR184I
        i8+CiAgIDx4czplbnVtZXJhdGlvbiB2YWx1ZT0iTEVBS0FHRV9ERVRFQ1RFRF85Ii8+CiAgP
        C94czpyZXN0cmljdGlvbj4KIDwveHM6c2ltcGxlVHlwZT4KIDx4czplbGVtZW50IHR5cGU9I
        nRuczpab25lU3RhdHVzRW51bWVyYXRpb24iIG5hbWU9IlpvbmVTdGF0dXNFbnVtZXJhdGlvb
        iIvPgogPHhzOmNvbXBsZXhUeXBlIG5hbWU9Ikxpc3RPZlpvbmVTdGF0dXNFbnVtZXJhdGlvb
        iI+CiAgPHhzOnNlcXVlbmNlPgogICA8eHM6ZWxlbWVudCBtaW5PY2N1cnM9IjAiIG1heE9jY
        3Vycz0idW5ib3VuZGVkIiB0eXBlPSJ0bnM6Wm9uZVN0YXR1c0VudW1lcmF0aW9uIiBuYW1lP
        SJab25lU3RhdHVzRW51bWVyYXRpb24iIG5pbGxhYmxlPSJ0cnVlIi8+CiAgPC94czpzZXF1Z
        W5jZT4KIDwveHM6Y29tcGxleFR5cGU+CiA8eHM6ZWxlbWVudCB0eXBlPSJ0bnM6TGlzdE9mW
        m9uZVN0YXR1c0VudW1lcmF0aW9uIiBuYW1lPSJMaXN0T2Zab25lU3RhdHVzRW51bWVyYXRpb
        24iIG5pbGxhYmxlPSJ0cnVlIi8+CiA8eHM6Y29tcGxleFR5cGUgbmFtZT0iVGltZU1ldGhvZ
        FBJRFBhcmFtZXRlcnNEYXRhVHlwZSI+CiAgPHhzOnNlcXVlbmNlPgogICA8eHM6ZWxlbWVud
        CBtaW5PY2N1cnM9IjAiIG1heE9jY3Vycz0iMSIgdHlwZT0ieHM6ZG91YmxlIiBuYW1lPSJYc
        CIvPgogICA8eHM6ZWxlbWVudCBtaW5PY2N1cnM9IjAiIG1heE9jY3Vycz0iMSIgdHlwZT0ie
        HM6ZG91YmxlIiBuYW1lPSJUbiIvPgogICA8eHM6ZWxlbWVudCBtaW5PY2N1cnM9IjAiIG1he
        E9jY3Vycz0iMSIgdHlwZT0ieHM6ZG91YmxlIiBuYW1lPSJUdiIvPgogICA8eHM6ZWxlbWVud
        CBtaW5PY2N1cnM9IjAiIG1heE9jY3Vycz0iMSIgdHlwZT0ieHM6ZG91YmxlIiBuYW1lPSJUc
        yIvPgogIDwveHM6c2VxdWVuY2U+CiA8L3hzOmNvbXBsZXhUeXBlPgogPHhzOmVsZW1lbnQgd
        HlwZT0idG5zOlRpbWVNZXRob2RQSURQYXJhbWV0ZXJzRGF0YVR5cGUiIG5hbWU9IlRpbWVNZ
        XRob2RQSURQYXJhbWV0ZXJzRGF0YVR5cGUiLz4KIDx4czpjb21wbGV4VHlwZSBuYW1lPSJMa
        XN0T2ZUaW1lTWV0aG9kUElEUGFyYW1ldGVyc0RhdGFUeXBlIj4KICA8eHM6c2VxdWVuY2U+C
        iAgIDx4czplbGVtZW50IG1pbk9jY3Vycz0iMCIgbWF4T2NjdXJzPSJ1bmJvdW5kZWQiIHR5c
        GU9InRuczpUaW1lTWV0aG9kUElEUGFyYW1ldGVyc0RhdGFUeXBlIiBuYW1lPSJUaW1lTWV0a
        G9kUElEUGFyYW1ldGVyc0RhdGFUeXBlIiBuaWxsYWJsZT0idHJ1ZSIvPgogIDwveHM6c2Vxd
        WVuY2U+CiA8L3hzOmNvbXBsZXhUeXBlPgogPHhzOmVsZW1lbnQgdHlwZT0idG5zOkxpc3RPZ
        lRpbWVNZXRob2RQSURQYXJhbWV0ZXJzRGF0YVR5cGUiIG5hbWU9Ikxpc3RPZlRpbWVNZXRob
        2RQSURQYXJhbWV0ZXJzRGF0YVR5cGUiIG5pbGxhYmxlPSJ0cnVlIi8+CjwveHM6c2NoZW1hP
        go=</uax:ByteString>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6020" BrowseName="NamespaceUri" ParentNodeId="ns=1;i=6019" DataType="String">
    <DisplayName>NamespaceUri</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6019</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">http://opcfoundation.org/UA/PlasticsRubber/HotRunner/Types.xsd</uax:String>
    </Value>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1002" BrowseName="1:ZoneAlarmType">
    <DisplayName>ZoneAlarmType</DisplayName>
    <Description>Represent zone-related text messages of an HRD</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/18.2</Documentation>
    <References>
      <Reference ReferenceType="HasSubtype" IsForward="false">ns=2;i=1052</Reference>
    </References>
  </UAObjectType>
  <UAObjectType NodeId="ns=1;i=1005" BrowseName="1:ControllerType">
    <DisplayName>ControllerType</DisplayName>
    <Description>Configuration and operation of the zone controller</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/15.1</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6034</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6025</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6022</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6500</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6036</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6028</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6030</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6031</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6021</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6032</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6023</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6026</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6041</Reference>
    </References>
  </UAObjectType>
  <UAVariable NodeId="ns=1;i=6034" BrowseName="1:ActualOutput" ParentNodeId="ns=1;i=1005" DataType="Double">
    <DisplayName>ActualOutput</DisplayName>
    <Description>Indicates the currently active output in percent</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6044</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6035</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6044" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6034" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6034</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6035" BrowseName="EURange" ParentNodeId="ns=1;i=6034" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6034</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6025" BrowseName="1:ActualType" ParentNodeId="ns=1;i=1005" DataType="ControllerTypeEnumeration">
    <DisplayName>ActualType</DisplayName>
    <Description>Actual value for the controller type used by the zone</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Int32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Int32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6022" BrowseName="1:ActualValueActive" ParentNodeId="ns=1;i=1005" DataType="Boolean">
    <DisplayName>ActualValueActive</DisplayName>
    <Description>Indicates the current status of the controller</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6500" BrowseName="1:AutomaticReferenceZoneSelection" ParentNodeId="ns=1;i=1005" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticReferenceZoneSelection</DisplayName>
    <Description>If true, the HRD selects automatically the reference zone.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6036" BrowseName="1:AverageControllerOutput" ParentNodeId="ns=1;i=1005" DataType="Double">
    <DisplayName>AverageControllerOutput</DisplayName>
    <Description>Indicates the average output which can be used when a sensor is broken</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6045</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6037</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6045" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6036" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6036</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6037" BrowseName="EURange" ParentNodeId="ns=1;i=6036" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6036</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5040" BrowseName="1:LoadCurrent" ParentNodeId="ns=1;i=1005">
    <DisplayName>LoadCurrent</DisplayName>
    <Description>Information about the load current in Ampere</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6038</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6081</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6107</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6152</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6304</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6324</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6511</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6513</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7027</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6516</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6518</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6520</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6713</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6522</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6524</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6038" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5040" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6043</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6039</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6043" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6038" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6038</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6039" BrowseName="EURange" ParentNodeId="ns=1;i=6038" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6038</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6081" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5040" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6082</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6106</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6082" BrowseName="EnumValues" ParentNodeId="ns=1;i=6081" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6081</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6106" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6081" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6081</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6107" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5040" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6152" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5040" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6526</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6153</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6526" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6152" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6152</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6153" BrowseName="EURange" ParentNodeId="ns=1;i=6152" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6152</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6304" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5040" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6527</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6314</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6527" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6304" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6304</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6314" BrowseName="EURange" ParentNodeId="ns=1;i=6304" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6304</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6324" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5040" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6528</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6510</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6528" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6324" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6324</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6510" BrowseName="EURange" ParentNodeId="ns=1;i=6324" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6324</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6511" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5040" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6529</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6512</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6529" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6511" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6511</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6512" BrowseName="EURange" ParentNodeId="ns=1;i=6511" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6511</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6513" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5040" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6514</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6515</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6514" BrowseName="EnumValues" ParentNodeId="ns=1;i=6513" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6513</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6515" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6513" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6513</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7027" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5040" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6516" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5040" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6530</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6517</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6530" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6516" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6516</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6517" BrowseName="EURange" ParentNodeId="ns=1;i=6516" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6516</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6518" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5040" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6531</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6519</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6531" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6518" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6518</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6519" BrowseName="EURange" ParentNodeId="ns=1;i=6518" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6518</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6520" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5040" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6532</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6521</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6532" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6520" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6520</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6521" BrowseName="EURange" ParentNodeId="ns=1;i=6520" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6520</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6713" BrowseName="2:Status" ParentNodeId="ns=1;i=5040" DataType="UInt16">
    <DisplayName>Status</DisplayName>
    <Description>Information if the ActualValue is within the tolerances or has passed a tolerance or min/max value</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6714</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6715</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6714" BrowseName="EnumValues" ParentNodeId="ns=1;i=6713" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6713</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6715" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6713" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6713</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6522" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5040" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6533</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6523</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6533" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6522" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6522</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6523" BrowseName="EURange" ParentNodeId="ns=1;i=6522" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6522</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6524" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5040" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6534</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6525</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5040</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6534" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6524" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6524</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6525" BrowseName="EURange" ParentNodeId="ns=1;i=6524" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6524</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5044" BrowseName="1:LoadPower" ParentNodeId="ns=1;i=1005">
    <DisplayName>LoadPower</DisplayName>
    <Description>Information about the load power in Watt</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6665</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6668</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6671</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6672</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6674</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6676</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6678</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6680</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7033</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6683</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6685</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6687</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6485</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6689</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6691</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6665" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5044" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6667</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6666</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6667" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6665" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6665</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6666" BrowseName="EURange" ParentNodeId="ns=1;i=6665" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6665</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6668" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5044" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6669</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6670</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6669" BrowseName="EnumValues" ParentNodeId="ns=1;i=6668" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6668</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6670" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6668" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6668</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6671" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5044" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6672" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6693</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6673</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6693" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6672" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6672</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6673" BrowseName="EURange" ParentNodeId="ns=1;i=6672" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6672</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6674" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6694</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6675</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6694" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6674" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6674</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6675" BrowseName="EURange" ParentNodeId="ns=1;i=6674" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6674</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6676" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6695</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6677</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6695" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6676" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6676</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6677" BrowseName="EURange" ParentNodeId="ns=1;i=6676" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6676</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6678" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6696</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6679</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6696" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6678" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6678</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6679" BrowseName="EURange" ParentNodeId="ns=1;i=6678" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6678</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6680" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5044" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6681</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6682</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6681" BrowseName="EnumValues" ParentNodeId="ns=1;i=6680" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6680</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6682" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6680" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6680</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7033" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5044" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6683" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5044" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6697</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6684</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6697" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6683" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6683</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6684" BrowseName="EURange" ParentNodeId="ns=1;i=6683" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6683</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6685" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5044" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6698</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6686</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6698" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6685" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6685</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6686" BrowseName="EURange" ParentNodeId="ns=1;i=6685" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6685</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6687" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6699</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6688</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6699" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6687" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6687</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6688" BrowseName="EURange" ParentNodeId="ns=1;i=6687" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6687</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6485" BrowseName="2:Status" ParentNodeId="ns=1;i=5044" DataType="UInt16">
    <DisplayName>Status</DisplayName>
    <Description>Information if the ActualValue is within the tolerances or has passed a tolerance or min/max value</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6702</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6703</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6702" BrowseName="EnumValues" ParentNodeId="ns=1;i=6485" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6485</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6703" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6485" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6485</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6689" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6700</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6690</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6700" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6689" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6689</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6690" BrowseName="EURange" ParentNodeId="ns=1;i=6689" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6689</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6691" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5044" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6701</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6692</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5044</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6701" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6691" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6691</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6692" BrowseName="EURange" ParentNodeId="ns=1;i=6691" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6691</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6028" BrowseName="1:LowerOutput" ParentNodeId="ns=1;i=1005" DataType="Double" AccessLevel="3">
    <DisplayName>LowerOutput</DisplayName>
    <Description>Limitation of the minimum output in closed-loop control in %</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6046</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6029</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6046" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6028" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6028</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6029" BrowseName="EURange" ParentNodeId="ns=1;i=6028" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6028</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6030" BrowseName="1:OutputTime" ParentNodeId="ns=1;i=1005" DataType="Duration" AccessLevel="3">
    <DisplayName>OutputTime</DisplayName>
    <Description>Time basis for operating the actuator</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6031" BrowseName="1:ReferenceZone" ParentNodeId="ns=1;i=1005" DataType="UInt32" AccessLevel="3">
    <DisplayName>ReferenceZone</DisplayName>
    <Description>If zones are to operate parallel to a control zone, the reference relation can be realised with this parameter.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1005</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6021" BrowseName="1:SetValueActive" ParentNodeId="ns=1;i=1005" DataType="Boolean" AccessLevel="3">
    <DisplayName>SetValueActive</DisplayName>
    <Description>A control zone is switched on and off with this parameter.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1005</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6032" BrowseName="1:SetValueManualOutput" ParentNodeId="ns=1;i=1005" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueManualOutput</DisplayName>
    <Description>Manually given output in percent if SetValueType = MANUAL is selected</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6047</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6033</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6047" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6032" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6032</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6033" BrowseName="EURange" ParentNodeId="ns=1;i=6032" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6032</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6023" BrowseName="1:SetValueType" ParentNodeId="ns=1;i=1005" DataType="UInt16" AccessLevel="3">
    <DisplayName>SetValueType</DisplayName>
    <Description>Set value for the controller type used by the zone</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6024</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6062</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6024" BrowseName="EnumValues" ParentNodeId="ns=1;i=6023" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6023</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6062" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6023" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6023</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6026" BrowseName="1:UpperOutput" ParentNodeId="ns=1;i=1005" DataType="Double" AccessLevel="3">
    <DisplayName>UpperOutput</DisplayName>
    <Description>Limitation of the maximum output in closed-loop control in %</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6048</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6027</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6048" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6026" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6026</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6027" BrowseName="EURange" ParentNodeId="ns=1;i=6026" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6026</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6041" BrowseName="1:UpperSetValueCascade" ParentNodeId="ns=1;i=1005" DataType="Double" AccessLevel="3">
    <DisplayName>UpperSetValueCascade</DisplayName>
    <Description>If the two controllers are cascaded, the master defines to which nominal temperature value the slave is to control to. With this parameter, the upper limit for the slave is defined.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6049</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6042</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1005</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6049" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6041" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6041</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6042" BrowseName="EURange" ParentNodeId="ns=1;i=6041" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6041</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1004" BrowseName="1:HeatUpType">
    <DisplayName>HeatUpType</DisplayName>
    <Description>Alternative to the SetRamp functionality of MonitoredParameterType defined in OPC 40083. With HeatUpType, it can be pre-defined how the control circuit is to be operated when it is switched on for the next time; with or without heat-up process.</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/16.1</Documentation>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6013</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6008</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6238</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6484</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6009</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6011</Reference>
    </References>
  </UAObjectType>
  <UAVariable NodeId="ns=1;i=6013" BrowseName="1:EvenHeatUpEnabled" ParentNodeId="ns=1;i=1004" DataType="Boolean" AccessLevel="3">
    <DisplayName>EvenHeatUpEnabled</DisplayName>
    <Description>Enables even heat-up process until nominal SetValue of Temperature of ZoneType is reached</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1004</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6008" BrowseName="1:ManualOutputLimitActive" ParentNodeId="ns=1;i=1004" DataType="Boolean" AccessLevel="3">
    <DisplayName>ManualOutputLimitActive</DisplayName>
    <Description>Activates heat-up process with pre-defined SetValueManualOutputLimit until SetValueTemperature is reached</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1004</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6238" BrowseName="1:RelayHeatingGroup" ParentNodeId="ns=1;i=1004" DataType="Byte" AccessLevel="3">
    <DisplayName>RelayHeatingGroup</DisplayName>
    <Description>Number of the heating group for relay heating</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1004</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6484" BrowseName="1:RelayHeatingTime" ParentNodeId="ns=1;i=1004" DataType="Duration" AccessLevel="3">
    <DisplayName>RelayHeatingTime</DisplayName>
    <Description>Time for relay heating of the zone. When RelayHeatingTime of all zones of a heating group have expired, the next group starts heating.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1004</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6009" BrowseName="1:SetValueManualOutputLimit" ParentNodeId="ns=1;i=1004" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueManualOutputLimit</DisplayName>
    <Description>This pre-defined maximum output (in percent) is valid until the SetValueTemperature is reached.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6014</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6010</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1004</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6014" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6009" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6009</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6010" BrowseName="EURange" ParentNodeId="ns=1;i=6009" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6009</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6011" BrowseName="1:SetValueTemperature" ParentNodeId="ns=1;i=1004" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueTemperature</DisplayName>
    <Description>If ManualOutputLimitActive is set, SetValueManualOutputLimit is active until this nominal temperature value is reached.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6015</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6012</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1004</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6015" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6011" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6011</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6012" BrowseName="EURange" ParentNodeId="ns=1;i=6011" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6011</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1010" BrowseName="1:HRD_InterfaceType">
    <DisplayName>HRD_InterfaceType</DisplayName>
    <Description>Root ObjectType representing a hot runner device with its subcomponents</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/6.1</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5022</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6240</Reference>
      <Reference ReferenceType="GeneratesEvent">ns=2;i=1052</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5016</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5023</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5017</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5018</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5022" BrowseName="1:Diagnostics" ParentNodeId="ns=1;i=1010">
    <DisplayName>Diagnostics</DisplayName>
    <Description>Diagnosis functions to check, for example, the wiring to the heating system or the sensor and heater allocation</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1066</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7009</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6237</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7010</Reference>
    </References>
  </UAObject>
  <UAMethod NodeId="ns=1;i=7009" BrowseName="2:RunDiagnostics" ParentNodeId="ns=1;i=5022" MethodDeclarationId="ns=2;i=7059">
    <DisplayName>RunDiagnostics</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6237" BrowseName="2:Status" ParentNodeId="ns=1;i=5022" DataType="DiagnosticsStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5022</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7010" BrowseName="2:StopDiagnostics" ParentNodeId="ns=1;i=5022" MethodDeclarationId="ns=2;i=7060">
    <DisplayName>StopDiagnostics</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5022</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6240" BrowseName="1:DisplayLanguage" ParentNodeId="ns=1;i=1010" DataType="LocaleId" AccessLevel="3">
    <DisplayName>DisplayLanguage</DisplayName>
    <Description>Setting of desired language on the user interface at the HRD</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5015" BrowseName="1:Identification" ParentNodeId="ns=1;i=1010">
    <DisplayName>Identification</DisplayName>
    <Description>Identification of the device </Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6241</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6242</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6218</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6243</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6486</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6487</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1058</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6219</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6488</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6220</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6489</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6490</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6491</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6221</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6492</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6493</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6241" BrowseName="3:AssetId" ParentNodeId="ns=1;i=5015" DataType="String">
    <DisplayName>AssetId</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6242" BrowseName="3:ComponentName" ParentNodeId="ns=1;i=5015" DataType="LocalizedText">
    <DisplayName>ComponentName</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6218" BrowseName="3:DeviceClass" ParentNodeId="ns=1;i=5015" DataType="String">
    <DisplayName>DeviceClass</DisplayName>
    <Description>Indicates in which domain or for what purpose a certain device is used</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6243" BrowseName="3:DeviceManual" ParentNodeId="ns=1;i=5015" DataType="String">
    <DisplayName>DeviceManual</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6486" BrowseName="3:DeviceRevision" ParentNodeId="ns=1;i=5015" DataType="String">
    <DisplayName>DeviceRevision</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6487" BrowseName="3:HardwareRevision" ParentNodeId="ns=1;i=5015" DataType="String">
    <DisplayName>HardwareRevision</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6219" BrowseName="3:Manufacturer" ParentNodeId="ns=1;i=5015" DataType="LocalizedText">
    <DisplayName>Manufacturer</DisplayName>
    <Description>Provides the name of the manufacturer of the machine</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6488" BrowseName="3:ManufacturerUri" ParentNodeId="ns=1;i=5015" DataType="String">
    <DisplayName>ManufacturerUri</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6220" BrowseName="3:Model" ParentNodeId="ns=1;i=5015" DataType="LocalizedText">
    <DisplayName>Model</DisplayName>
    <Description>Represents the name of the machine type</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6489" BrowseName="3:ProductCode" ParentNodeId="ns=1;i=5015" DataType="String">
    <DisplayName>ProductCode</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6490" BrowseName="3:ProductInstanceUri" ParentNodeId="ns=1;i=5015" DataType="String">
    <DisplayName>ProductInstanceUri</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6491" BrowseName="3:RevisionCounter" ParentNodeId="ns=1;i=5015" DataType="Int32">
    <DisplayName>RevisionCounter</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6221" BrowseName="3:SerialNumber" ParentNodeId="ns=1;i=5015" DataType="String">
    <DisplayName>SerialNumber</DisplayName>
    <Description>Represents the serial number of the machine (unique ID given by the manufacturer)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6492" BrowseName="3:SoftwareRevision" ParentNodeId="ns=1;i=5015" DataType="String">
    <DisplayName>SoftwareRevision</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6493" BrowseName="2:YearOfConstruction" ParentNodeId="ns=1;i=5015" DataType="UInt16">
    <DisplayName>YearOfConstruction</DisplayName>
    <Description>Represents the year of construction of the machine</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5015</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5016" BrowseName="1:MachineConfiguration" ParentNodeId="ns=1;i=1010">
    <DisplayName>MachineConfiguration</DisplayName>
    <Description>Current configuration of the hot runner device</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=7011</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7012</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6222</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1016</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6329</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7008</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6224</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6225</Reference>
    </References>
  </UAObject>
  <UAMethod NodeId="ns=1;i=7011" BrowseName="2:GetCurrentPage" ParentNodeId="ns=1;i=5016" MethodDeclarationId="ns=2;i=7017">
    <DisplayName>GetCurrentPage</DisplayName>
    <Description>Method for retrieving a screenshot of the control system with the currently shown contents</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5016</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6244</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6245</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6244" BrowseName="InputArguments" ParentNodeId="ns=1;i=7011" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7011</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:ExtensionObject>
          <uax:TypeId>
            <uax:Identifier>i=297</uax:Identifier>
          </uax:TypeId>
          <uax:Body>
            <uax:Argument>
              <uax:Name>VisualisationUnit</uax:Name>
              <uax:DataType>
                <uax:Identifier>i=7</uax:Identifier>
              </uax:DataType>
              <uax:ValueRank>-1</uax:ValueRank>
              <uax:ArrayDimensions />
              <uax:Description />
            </uax:Argument>
          </uax:Body>
        </uax:ExtensionObject>
      </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6245" BrowseName="OutputArguments" ParentNodeId="ns=1;i=7011" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>OutputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7011</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:ExtensionObject>
          <uax:TypeId>
            <uax:Identifier>i=297</uax:Identifier>
          </uax:TypeId>
          <uax:Body>
            <uax:Argument>
              <uax:Name>Page</uax:Name>
              <uax:DataType>
                <uax:Identifier>i=30</uax:Identifier>
              </uax:DataType>
              <uax:ValueRank>-1</uax:ValueRank>
              <uax:ArrayDimensions />
              <uax:Description />
            </uax:Argument>
          </uax:Body>
        </uax:ExtensionObject>
      </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7012" BrowseName="2:GetPage" ParentNodeId="ns=1;i=5016" MethodDeclarationId="ns=2;i=7018">
    <DisplayName>GetPage</DisplayName>
    <Description>Method for retrieving the image of a page of the control system</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5016</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6246</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6247</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6246" BrowseName="InputArguments" ParentNodeId="ns=1;i=7012" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7012</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:ExtensionObject>
          <uax:TypeId>
            <uax:Identifier>i=297</uax:Identifier>
          </uax:TypeId>
          <uax:Body>
            <uax:Argument>
              <uax:Name>Id</uax:Name>
              <uax:DataType>
                <uax:Identifier>i=12</uax:Identifier>
              </uax:DataType>
              <uax:ValueRank>-1</uax:ValueRank>
              <uax:ArrayDimensions />
              <uax:Description />
            </uax:Argument>
          </uax:Body>
        </uax:ExtensionObject>
      </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6247" BrowseName="OutputArguments" ParentNodeId="ns=1;i=7012" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>OutputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7012</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:ExtensionObject>
          <uax:TypeId>
            <uax:Identifier>i=297</uax:Identifier>
          </uax:TypeId>
          <uax:Body>
            <uax:Argument>
              <uax:Name>Page</uax:Name>
              <uax:DataType>
                <uax:Identifier>i=30</uax:Identifier>
              </uax:DataType>
              <uax:ValueRank>-1</uax:ValueRank>
              <uax:ArrayDimensions />
              <uax:Description />
            </uax:Argument>
          </uax:Body>
        </uax:ExtensionObject>
      </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6222" BrowseName="2:LocationName" ParentNodeId="ns=1;i=5016" DataType="String" AccessLevel="3">
    <DisplayName>LocationName</DisplayName>
    <Description>Description of the location of the machine given by the machine operator or OPC client</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5016</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
      </uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6329" BrowseName="2:PageDirectory" ParentNodeId="ns=1;i=5016" DataType="PageEntryDataType" ValueRank="1">
    <DisplayName>PageDirectory</DisplayName>
    <Description>List of the pages that are implemented in the machine control system and are shown on the screen of the machine</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5016</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7008" BrowseName="2:SetMachineTime" ParentNodeId="ns=1;i=5016" MethodDeclarationId="ns=2;i=7019">
    <DisplayName>SetMachineTime</DisplayName>
    <Description>Method for setting the server time together with TimeZoneOffset</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6223</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5016</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6223" BrowseName="InputArguments" ParentNodeId="ns=1;i=7008" DataType="Argument" ValueRank="1" ArrayDimensions="2">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7008</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:ExtensionObject>
          <uax:TypeId>
            <uax:Identifier>i=297</uax:Identifier>
          </uax:TypeId>
          <uax:Body>
            <uax:Argument>
              <uax:Name>DateTime</uax:Name>
              <uax:DataType>
                <uax:Identifier>i=13</uax:Identifier>
              </uax:DataType>
              <uax:ValueRank>-1</uax:ValueRank>
              <uax:ArrayDimensions />
              <uax:Description />
            </uax:Argument>
          </uax:Body>
        </uax:ExtensionObject>
        <uax:ExtensionObject>
          <uax:TypeId>
            <uax:Identifier>i=297</uax:Identifier>
          </uax:TypeId>
          <uax:Body>
            <uax:Argument>
              <uax:Name>TimeZoneOffset</uax:Name>
              <uax:DataType>
                <uax:Identifier>i=8912</uax:Identifier>
              </uax:DataType>
              <uax:ValueRank>-1</uax:ValueRank>
              <uax:ArrayDimensions />
              <uax:Description />
            </uax:Argument>
          </uax:Body>
        </uax:ExtensionObject>
      </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6224" BrowseName="2:TimeZoneOffset" ParentNodeId="ns=1;i=5016" DataType="TimeZoneDataType" AccessLevel="3">
    <DisplayName>TimeZoneOffset</DisplayName>
    <Description>Difference of the local time to Coordinated Universal Time (UTC) given by the machine operator or OPC client</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5016</Reference>
    </References>
    <Value>
      <uax:ExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:TypeId>
          <uax:Identifier>i=8913</uax:Identifier>
        </uax:TypeId>
        <uax:Body>
          <TimeZoneDataType xmlns="http://opcfoundation.org/UA/2008/02/Types.xsd">
            <Offset>0</Offset>
            <DaylightSavingInOffset>false</DaylightSavingInOffset>
          </TimeZoneDataType>
        </uax:Body>
      </uax:ExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6225" BrowseName="2:UserMachineName" ParentNodeId="ns=1;i=5016" DataType="String" AccessLevel="3">
    <DisplayName>UserMachineName</DisplayName>
    <Description>Description of the machine given by the machine operator or OPC client</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5016</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
      </uax:String>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5023" BrowseName="1:MaintenanceInformation" ParentNodeId="ns=1;i=1010">
    <DisplayName>MaintenanceInformation</DisplayName>
    <Description>Information about the maintenance status of various parts of a hot runner device</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5024</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5025</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1007</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5026</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5024" BrowseName="1:CoolingFan" ParentNodeId="ns=1;i=5023">
    <DisplayName>CoolingFan</DisplayName>
    <Description>Information about the maintenance status of the cooling fan</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6342</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5023</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6343</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6345</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7013</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6339</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6347</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6342" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5024" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5024</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6343" BrowseName="2:Interval" ParentNodeId="ns=1;i=5024" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <Description>Regular interval between two maintenances</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6364</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6344</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5024</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6364" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6343" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6343</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6344" BrowseName="EURange" ParentNodeId="ns=1;i=6343" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6343</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6345" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5024" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <Description>Interval before next maintenance is due</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6369</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6346</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5024</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6369" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6345" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6345</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6346" BrowseName="EURange" ParentNodeId="ns=1;i=6345" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6345</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7013" BrowseName="2:Reset" ParentNodeId="ns=1;i=5024" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the CurrentInterval to 0 and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5024</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6339" BrowseName="2:Status" ParentNodeId="ns=1;i=5024" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5024</Reference>
    </References>
    <Value>
      <uax:Int32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Int32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6347" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5024" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <Description>How long is the component running in total</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6371</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6348</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5024</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6371" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6347" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6347</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6348" BrowseName="EURange" ParentNodeId="ns=1;i=6347" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6347</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5025" BrowseName="1:Heating" ParentNodeId="ns=1;i=5023">
    <DisplayName>Heating</DisplayName>
    <Description>Information about the maintenance status of the heating</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6349</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5023</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6350</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6352</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7014</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6340</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6354</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6349" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5025" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5025</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6350" BrowseName="2:Interval" ParentNodeId="ns=1;i=5025" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <Description>Regular interval between two maintenances</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6365</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6351</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5025</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6365" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6350" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6350</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6351" BrowseName="EURange" ParentNodeId="ns=1;i=6350" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6350</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6352" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5025" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <Description>Interval before next maintenance is due</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6366</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6353</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5025</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6366" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6352" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6352</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6353" BrowseName="EURange" ParentNodeId="ns=1;i=6352" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6352</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7014" BrowseName="2:Reset" ParentNodeId="ns=1;i=5025" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the CurrentInterval to 0 and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5025</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6340" BrowseName="2:Status" ParentNodeId="ns=1;i=5025" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5025</Reference>
    </References>
    <Value>
      <uax:Int32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Int32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6354" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5025" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <Description>How long is the component running in total</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6367</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6355</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5025</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6367" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6354" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6354</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6355" BrowseName="EURange" ParentNodeId="ns=1;i=6354" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6354</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5026" BrowseName="1:SafetyTest" ParentNodeId="ns=1;i=5023">
    <DisplayName>SafetyTest</DisplayName>
    <Description>Information about the maintenance status of the safety test</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6356</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6357</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6359</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7015</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5023</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6341</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6361</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6356" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5026" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5026</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6357" BrowseName="2:Interval" ParentNodeId="ns=1;i=5026" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <Description>Regular interval between two maintenances</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6375</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6358</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6375" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6357" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6357</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6358" BrowseName="EURange" ParentNodeId="ns=1;i=6357" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6357</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6359" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5026" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <Description>Interval before next maintenance is due</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6376</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6360</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6376" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6359" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6359</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6360" BrowseName="EURange" ParentNodeId="ns=1;i=6359" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6359</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7015" BrowseName="2:Reset" ParentNodeId="ns=1;i=5026" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the CurrentInterval to 0 and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6341" BrowseName="2:Status" ParentNodeId="ns=1;i=5026" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5026</Reference>
    </References>
    <Value>
      <uax:Int32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Int32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6361" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5026" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <Description>How long is the component running in total</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6377</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6362</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5026</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6377" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6361" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6361</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6362" BrowseName="EURange" ParentNodeId="ns=1;i=6361" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6361</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5017" BrowseName="1:Operation" ParentNodeId="ns=1;i=1010">
    <DisplayName>Operation</DisplayName>
    <Description>Contains components which are necessary to operate the HRD</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6227</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6252</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6226</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6251</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6508</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6303</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7017</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6497</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7016</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7020</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6650</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7032</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6227" BrowseName="1:ActiveErrors" ParentNodeId="ns=1;i=5017" DataType="ClassifiedActiveErrorDataType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>ActiveErrors</DisplayName>
    <Description>List of the active errors of the device</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5017</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6252" BrowseName="1:ActiveSetValues" ParentNodeId="ns=1;i=5017" DataType="UInt16" AccessLevel="3">
    <DisplayName>ActiveSetValues</DisplayName>
    <Description>Central selection of the used set temperature for the temperature zones </Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5017</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6395</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6396</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6395" BrowseName="EnumValues" ParentNodeId="ns=1;i=6252" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6252</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6396" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6252" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6252</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6226" BrowseName="1:DeviceMappingNumber" ParentNodeId="ns=1;i=5017" DataType="UInt32" AccessLevel="3">
    <DisplayName>DeviceMappingNumber</DisplayName>
    <Description>Unique identifier/address/number for devices of the same DeviceType within a local network</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5017</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6251" BrowseName="1:EnablePower" ParentNodeId="ns=1;i=5017" DataType="Boolean" AccessLevel="3">
    <DisplayName>EnablePower</DisplayName>
    <Description>Global power control switch for all zone controllers</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5017</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6508" BrowseName="1:EvenHeatUpMaxTemperatureDifference" ParentNodeId="ns=1;i=5017" DataType="Double" AccessLevel="3">
    <DisplayName>EvenHeatUpMaxTemperatureDifference</DisplayName>
    <Description>Definition of the maximum temperature difference of all zones during even heat-up </Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6648</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6509</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5017</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6648" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6508" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6508</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6509" BrowseName="EURange" ParentNodeId="ns=1;i=6508" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6508</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6303" BrowseName="1:HighestActiveAlarmSeverity" ParentNodeId="ns=1;i=5017" DataType="UInt16">
    <DisplayName>HighestActiveAlarmSeverity</DisplayName>
    <Description>Indication of the severity of the highest active alarm</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5017</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7017" BrowseName="1:IdentifyDevice" ParentNodeId="ns=1;i=5017" MethodDeclarationId="ns=1;i=7006">
    <DisplayName>IdentifyDevice</DisplayName>
    <Description>The peripheral device on which this method is called shows itself by e.g. activation of a LED.</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/9.2</Documentation>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5017</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6497" BrowseName="1:ReactionOnDisconnect" ParentNodeId="ns=1;i=5017" DataType="UInt16">
    <DisplayName>ReactionOnDisconnect</DisplayName>
    <Description>Selection of the set temperature for the temperature zones in case of a disconnection from the OPC UA client </Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6498</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5017</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6499</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6498" BrowseName="EnumValues" ParentNodeId="ns=1;i=6497" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6497</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6499" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6497" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6497</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7016" BrowseName="1:ResetAllErrors" ParentNodeId="ns=1;i=5017" MethodDeclarationId="ns=1;i=7007">
    <DisplayName>ResetAllErrors</DisplayName>
    <Description>Method to reset all errors of the device</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/9.5</Documentation>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5017</Reference>
    </References>
  </UAMethod>
  <UAMethod NodeId="ns=1;i=7020" BrowseName="1:ResetErrorById" ParentNodeId="ns=1;i=5017" MethodDeclarationId="ns=1;i=7019">
    <DisplayName>ResetErrorById</DisplayName>
    <Description>Method to reset one error of the device</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/9.6</Documentation>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6379</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5017</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6379" BrowseName="InputArguments" ParentNodeId="ns=1;i=7020" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7020</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:ExtensionObject>
          <uax:TypeId>
            <uax:Identifier>i=297</uax:Identifier>
          </uax:TypeId>
          <uax:Body>
            <uax:Argument>
              <uax:Name>Id</uax:Name>
              <uax:DataType>
                <uax:Identifier>i=12</uax:Identifier>
              </uax:DataType>
              <uax:ValueRank>-1</uax:ValueRank>
              <uax:ArrayDimensions />
              <uax:Description />
            </uax:Argument>
          </uax:Body>
        </uax:ExtensionObject>
      </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6650" BrowseName="1:SessionNameForReactionOnDisconnect" ParentNodeId="ns=1;i=5017" DataType="String">
    <DisplayName>SessionNameForReactionOnDisconnect</DisplayName>
    <Description>Contains the sessionName of the connection with the client relevant for ReactionOnDisconnect</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5017</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7032" BrowseName="1:SetReactionOnDisconnect" ParentNodeId="ns=1;i=5017" MethodDeclarationId="ns=1;i=7031">
    <DisplayName>SetReactionOnDisconnect</DisplayName>
    <Description>Method to set ReactionOnDisconnect and SessionNameForReactionOnDisconnect</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/9.9</Documentation>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6652</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5017</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6652" BrowseName="InputArguments" ParentNodeId="ns=1;i=7032" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7032</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:ExtensionObject>
          <uax:TypeId>
            <uax:Identifier>i=297</uax:Identifier>
          </uax:TypeId>
          <uax:Body>
            <uax:Argument>
              <uax:Name>ReactionOnDisconnect</uax:Name>
              <uax:DataType>
                <uax:Identifier>i=5</uax:Identifier>
              </uax:DataType>
              <uax:ValueRank>-1</uax:ValueRank>
              <uax:ArrayDimensions />
              <uax:Description />
            </uax:Argument>
          </uax:Body>
        </uax:ExtensionObject>
      </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5018" BrowseName="1:Zones" ParentNodeId="ns=1;i=1010">
    <DisplayName>Zones</DisplayName>
    <Description>Container for the zones</Description>
    <References>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6228</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1010</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1008</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6228" BrowseName="NodeVersion" ParentNodeId="ns=1;i=5018" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5018</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
      </uax:String>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5019" BrowseName="1:Zone_&lt;Nr&gt;" SymbolicName="Zone__Nr_" ParentNodeId="ns=1;i=5018">
    <DisplayName>Zone_&lt;Nr&gt;</DisplayName>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6471</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6541</Reference>
      <Reference ReferenceType="HasModellingRule">i=11510</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6388</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5032</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6474</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5018</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1006</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6471" BrowseName="1:CommunicationProtocolType" ParentNodeId="ns=1;i=5019" DataType="UInt16" AccessLevel="3">
    <DisplayName>CommunicationProtocolType</DisplayName>
    <Description>Used communication protocol between the sensor and the control system of the HRD</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6472</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6473</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6472" BrowseName="EnumValues" ParentNodeId="ns=1;i=6471" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6471</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6473" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6471" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6471</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5020" BrowseName="1:Controller" ParentNodeId="ns=1;i=5019">
    <DisplayName>Controller</DisplayName>
    <Description>Setting and monitoring of the controller</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6108</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6229</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6230</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6138</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6110</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5043</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6112</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6114</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6115</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6231</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6116</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6326</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6119</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6121</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6108" BrowseName="1:ActualOutput" ParentNodeId="ns=1;i=5020" DataType="Double">
    <DisplayName>ActualOutput</DisplayName>
    <Description>Indicates the currently active output in percent</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6322</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6109</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6322" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6108" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6108</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6109" BrowseName="EURange" ParentNodeId="ns=1;i=6108" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6108</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6229" BrowseName="1:ActualType" ParentNodeId="ns=1;i=5020" DataType="ControllerTypeEnumeration">
    <DisplayName>ActualType</DisplayName>
    <Description>Actual value for the controller type used by the zone</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Int32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Int32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6230" BrowseName="1:ActualValueActive" ParentNodeId="ns=1;i=5020" DataType="Boolean">
    <DisplayName>ActualValueActive</DisplayName>
    <Description>Indicates the current status of the controller</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6138" BrowseName="1:AutomaticReferenceZoneSelection" ParentNodeId="ns=1;i=5020" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticReferenceZoneSelection</DisplayName>
    <Description>If true, the HRD selects automatically the reference zone.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6110" BrowseName="1:AverageControllerOutput" ParentNodeId="ns=1;i=5020" DataType="Double">
    <DisplayName>AverageControllerOutput</DisplayName>
    <Description>Indicates the average output which can be used when a sensor is broken</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6323</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6111</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6323" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6110" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6110</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6111" BrowseName="EURange" ParentNodeId="ns=1;i=6110" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6110</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5043" BrowseName="1:LoadCurrent" ParentNodeId="ns=1;i=5020">
    <DisplayName>LoadCurrent</DisplayName>
    <Description>Information about the load current in Ampere</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6539</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6613</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6616</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6617</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6620</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6623</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6626</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6629</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7030</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6632</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6635</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6638</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6722</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6641</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6644</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6539" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5043" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6612</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6540</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6612" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6539" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6539</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6540" BrowseName="EURange" ParentNodeId="ns=1;i=6539" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6539</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6613" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5043" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6614</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6615</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6614" BrowseName="EnumValues" ParentNodeId="ns=1;i=6613" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6613</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6615" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6613" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6613</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6616" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5043" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5043</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6617" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5043" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6618</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6619</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6618" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6617" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6617</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6619" BrowseName="EURange" ParentNodeId="ns=1;i=6617" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6617</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6620" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5043" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6621</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6622</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6621" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6620" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6620</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6622" BrowseName="EURange" ParentNodeId="ns=1;i=6620" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6620</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6623" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5043" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6624</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6625</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6624" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6623" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6623</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6625" BrowseName="EURange" ParentNodeId="ns=1;i=6623" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6623</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6626" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5043" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6627</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6628</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6627" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6626" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6626</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6628" BrowseName="EURange" ParentNodeId="ns=1;i=6626" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6626</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6629" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5043" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6630</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6631</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6630" BrowseName="EnumValues" ParentNodeId="ns=1;i=6629" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6629</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6631" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6629" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6629</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7030" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5043" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6632" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5043" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6633</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6634</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6633" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6632" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6632</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6634" BrowseName="EURange" ParentNodeId="ns=1;i=6632" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6632</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6635" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5043" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6636</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6637</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6636" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6635" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6635</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6637" BrowseName="EURange" ParentNodeId="ns=1;i=6635" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6635</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6638" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5043" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6639</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6640</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6639" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6638" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6638</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6640" BrowseName="EURange" ParentNodeId="ns=1;i=6638" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6638</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6722" BrowseName="2:Status" ParentNodeId="ns=1;i=5043" DataType="UInt16">
    <DisplayName>Status</DisplayName>
    <Description>Information if the ActualValue is within the tolerances or has passed a tolerance or min/max value</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6723</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6724</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6723" BrowseName="EnumValues" ParentNodeId="ns=1;i=6722" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6722</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6724" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6722" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6722</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6641" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5043" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6642</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6643</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6642" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6641" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6641</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6643" BrowseName="EURange" ParentNodeId="ns=1;i=6641" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6641</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6644" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5043" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6645</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6646</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5043</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6645" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6644" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6644</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6646" BrowseName="EURange" ParentNodeId="ns=1;i=6644" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6644</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5047" BrowseName="1:LoadPower" ParentNodeId="ns=1;i=5020">
    <DisplayName>LoadPower</DisplayName>
    <Description>Information about the load power in Watt</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6729</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6729" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5047" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5047</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6730</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6730" BrowseName="EURange" ParentNodeId="ns=1;i=6729" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6729</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6112" BrowseName="1:LowerOutput" ParentNodeId="ns=1;i=5020" DataType="Double" AccessLevel="3">
    <DisplayName>LowerOutput</DisplayName>
    <Description>Limitation of the minimum output in closed-loop control in %</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6320</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6113</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6320" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6112" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6112</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6113" BrowseName="EURange" ParentNodeId="ns=1;i=6112" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6112</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6114" BrowseName="1:OutputTime" ParentNodeId="ns=1;i=5020" DataType="Duration" AccessLevel="3">
    <DisplayName>OutputTime</DisplayName>
    <Description>Time basis for operating the actuator</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6115" BrowseName="1:ReferenceZone" ParentNodeId="ns=1;i=5020" DataType="UInt32" AccessLevel="3">
    <DisplayName>ReferenceZone</DisplayName>
    <Description>If zones are to operate parallel to a control zone, the reference relation can be realised with this parameter.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5020</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6231" BrowseName="1:SetValueActive" ParentNodeId="ns=1;i=5020" DataType="Boolean" AccessLevel="3">
    <DisplayName>SetValueActive</DisplayName>
    <Description>A control zone is switched on and off with this parameter.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5020</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6116" BrowseName="1:SetValueManualOutput" ParentNodeId="ns=1;i=5020" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueManualOutput</DisplayName>
    <Description>Manually given output in percent if SetValueType = MANUAL is selected</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6321</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6117</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5020</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6321" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6116" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6116</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6117" BrowseName="EURange" ParentNodeId="ns=1;i=6116" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6116</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6326" BrowseName="1:SetValueType" ParentNodeId="ns=1;i=5020" DataType="UInt16" AccessLevel="3">
    <DisplayName>SetValueType</DisplayName>
    <Description>Set value for the controller type used by the zone</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6327</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5020</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6328</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6327" BrowseName="EnumValues" ParentNodeId="ns=1;i=6326" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6326</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6328" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6326" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6326</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6119" BrowseName="1:UpperOutput" ParentNodeId="ns=1;i=5020" DataType="Double" AccessLevel="3">
    <DisplayName>UpperOutput</DisplayName>
    <Description>Limitation of the maximum output in closed-loop control in %</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6319</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6120</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5020</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6319" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6119" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6119</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6120" BrowseName="EURange" ParentNodeId="ns=1;i=6119" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6119</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6121" BrowseName="1:UpperSetValueCascade" ParentNodeId="ns=1;i=5020" DataType="Double" AccessLevel="3">
    <DisplayName>UpperSetValueCascade</DisplayName>
    <Description>If the two controllers are cascaded, the master defines to which nominal temperature value the slave is to control to. With this parameter, the upper limit for the slave is defined.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6325</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6122</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5020</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6325" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6121" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6121</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6122" BrowseName="EURange" ParentNodeId="ns=1;i=6121" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6121</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5031" BrowseName="1:HeatUp" ParentNodeId="ns=1;i=5019">
    <DisplayName>HeatUp</DisplayName>
    <Description>Setting for heat up procedure</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6438</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1004</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6439</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6468</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6469</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6440</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6443</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6438" BrowseName="1:EvenHeatUpEnabled" ParentNodeId="ns=1;i=5031" DataType="Boolean" AccessLevel="3">
    <DisplayName>EvenHeatUpEnabled</DisplayName>
    <Description>Enables even heat-up process until nominal SetValue of Temperature of ZoneType is reached</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6439" BrowseName="1:ManualOutputLimitActive" ParentNodeId="ns=1;i=5031" DataType="Boolean" AccessLevel="3">
    <DisplayName>ManualOutputLimitActive</DisplayName>
    <Description>Activates heat-up process with pre-defined SetValueManualOutputLimit until SetValueTemperature is reached</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5031</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6468" BrowseName="1:RelayHeatingGroup" ParentNodeId="ns=1;i=5031" DataType="Byte" AccessLevel="3">
    <DisplayName>RelayHeatingGroup</DisplayName>
    <Description>Number of the heating group for relay heating</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5031</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6469" BrowseName="1:RelayHeatingTime" ParentNodeId="ns=1;i=5031" DataType="Duration" AccessLevel="3">
    <DisplayName>RelayHeatingTime</DisplayName>
    <Description>Time for relay heating of the zone. When RelayHeatingTime of all zones of a heating group have expired, the next group starts heating.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5031</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6440" BrowseName="1:SetValueManualOutputLimit" ParentNodeId="ns=1;i=5031" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueManualOutputLimit</DisplayName>
    <Description>This pre-defined maximum output (in percent) is valid until the SetValueTemperature is reached.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6441</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6442</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6441" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6440" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6440</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6442" BrowseName="EURange" ParentNodeId="ns=1;i=6440" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6440</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6443" BrowseName="1:SetValueTemperature" ParentNodeId="ns=1;i=5031" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueTemperature</DisplayName>
    <Description>If ManualOutputLimitActive is set, SetValueManualOutputLimit is active until this nominal temperature value is reached.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6444</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6445</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5031</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6444" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6443" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6443</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6445" BrowseName="EURange" ParentNodeId="ns=1;i=6443" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6443</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6541" BrowseName="1:HighestActiveAlarmSeverity" ParentNodeId="ns=1;i=5019" DataType="UInt16">
    <DisplayName>HighestActiveAlarmSeverity</DisplayName>
    <Description>Indicates the severity of the highest active alarm related to the current zone</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6388" BrowseName="1:Name" ParentNodeId="ns=1;i=5019" DataType="String" AccessLevel="3">
    <DisplayName>Name</DisplayName>
    <Description>A user given name of the zone</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
      </uax:String>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5012" BrowseName="1:Temperature" ParentNodeId="ns=1;i=5019">
    <DisplayName>Temperature</DisplayName>
    <Description>Setting and monitoring of the temperature</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6662</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6123</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6282</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6285</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6458</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6504</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1011</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6286</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6288</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6290</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6294</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6296</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7026</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6291</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6299</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6301</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6401</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6460</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6710</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6505</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6403</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6405</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5019</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6662" BrowseName="1:ActiveSetValue" ParentNodeId="ns=1;i=5012" DataType="UInt16">
    <DisplayName>ActiveSetValue</DisplayName>
    <Description>Current active set temperature for the temperature zone </Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6663</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6664</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6663" BrowseName="EnumValues" ParentNodeId="ns=1;i=6662" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6662</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6664" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6662" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6662</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6123" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5012" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6127</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6124</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6127" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6123" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6123</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6124" BrowseName="EURange" ParentNodeId="ns=1;i=6123" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6123</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6282" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5012" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6283</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6284</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6283" BrowseName="EnumValues" ParentNodeId="ns=1;i=6282" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6282</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6284" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6282" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6282</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6285" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5012" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6458" BrowseName="1:BoostSetValue" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>BoostSetValue</DisplayName>
    <Description>Set value for boost mode</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6466</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6459</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6466" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6458" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6458</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6459" BrowseName="EURange" ParentNodeId="ns=1;i=6458" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6458</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6504" BrowseName="1:BoostTime" ParentNodeId="ns=1;i=5012" DataType="Duration" AccessLevel="3">
    <DisplayName>BoostTime</DisplayName>
    <Description>Duration of the boost mode after which the set value which was active before boost is becoming active again</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5027" BrowseName="2:ClosedLoopControl" ParentNodeId="ns=1;i=5012">
    <DisplayName>ClosedLoopControl</DisplayName>
    <Description>With this type the client can do settings for the closed loop control on the device for a parameter</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6131</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6146</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7018</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7023</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6147</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6131" BrowseName="2:AutomaticControllerMode" ParentNodeId="ns=1;i=5027" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticControllerMode</DisplayName>
    <Description>Determination if PID Parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6146" BrowseName="2:AutoTuningActive" ParentNodeId="ns=1;i=5027" DataType="Boolean">
    <DisplayName>AutoTuningActive</DisplayName>
    <Description>Informs if the automatic tuning is currently active</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7018" BrowseName="2:AutoTuningOff" ParentNodeId="ns=1;i=5027" MethodDeclarationId="ns=2;i=7048">
    <DisplayName>AutoTuningOff</DisplayName>
    <Description>Stops an already active self-optimisation process (no control parameters are changed)</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAMethod NodeId="ns=1;i=7023" BrowseName="2:AutoTuningOn" ParentNodeId="ns=1;i=5027" MethodDeclarationId="ns=2;i=7047">
    <DisplayName>AutoTuningOn</DisplayName>
    <Description>Starts the self-optimisation of the controller</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6147" BrowseName="2:PIDParameters" ParentNodeId="ns=1;i=5027" DataType="PIDParametersDataType" ValueRank="1" ArrayDimensions="0" AccessLevel="3">
    <DisplayName>PIDParameters</DisplayName>
    <Description>PID Parameters as array if several input signals (sensors) are used for the control</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5027</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6286" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6427</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6287</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6427" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6286" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6286</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6287" BrowseName="EURange" ParentNodeId="ns=1;i=6286" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6286</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6288" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6428</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6289</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6428" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6288" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6288</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6289" BrowseName="EURange" ParentNodeId="ns=1;i=6288" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6288</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6290" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6429</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6293</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6429" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6290" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6290</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6293" BrowseName="EURange" ParentNodeId="ns=1;i=6290" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6290</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6294" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6430</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6295</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6430" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6294" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6294</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6295" BrowseName="EURange" ParentNodeId="ns=1;i=6294" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6294</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6296" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5012" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6297</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6298</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6297" BrowseName="EnumValues" ParentNodeId="ns=1;i=6296" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6296</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6298" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6296" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6296</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7026" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5012" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6291" BrowseName="1:SecondSetValue" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>SecondSetValue</DisplayName>
    <Description>Second set value for fast switch-over</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6423</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6292</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6423" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6291" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6291</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6292" BrowseName="EURange" ParentNodeId="ns=1;i=6291" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6291</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6299" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6431</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6300</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6431" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6299" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6299</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6300" BrowseName="EURange" ParentNodeId="ns=1;i=6299" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6299</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6301" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6432</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6302</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6432" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6301" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6301</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6302" BrowseName="EURange" ParentNodeId="ns=1;i=6301" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6301</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6401" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6433</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6402</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6433" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6401" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6401</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6402" BrowseName="EURange" ParentNodeId="ns=1;i=6401" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6401</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6460" BrowseName="1:StandbySetValue" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>StandbySetValue</DisplayName>
    <Description>Set value for standby mode</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6467</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6461</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6467" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6460" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6460</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6461" BrowseName="EURange" ParentNodeId="ns=1;i=6460" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6460</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6710" BrowseName="2:Status" ParentNodeId="ns=1;i=5012" DataType="UInt16">
    <DisplayName>Status</DisplayName>
    <Description>Information if the ActualValue is within the tolerances or has passed a tolerance or min/max value</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6711</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6712</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6711" BrowseName="EnumValues" ParentNodeId="ns=1;i=6710" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6710</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6712" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6710" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6710</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6505" BrowseName="1:TimeMethodPIDParameters" ParentNodeId="ns=1;i=5012" DataType="TimeMethodPIDParametersDataType" ValueRank="1" ArrayDimensions="0" AccessLevel="3">
    <DisplayName>TimeMethodPIDParameters</DisplayName>
    <Description>Setting of PID parameters with time method</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5012</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6403" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6434</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6404</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6434" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6403" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6403</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6404" BrowseName="EURange" ParentNodeId="ns=1;i=6403" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6403</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6405" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5012" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6435</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6406</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5012</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6435" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6405" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6405</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6406" BrowseName="EURange" ParentNodeId="ns=1;i=6405" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6405</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5032" BrowseName="1:TemperatureRiseMonitoring" ParentNodeId="ns=1;i=5019">
    <DisplayName>TemperatureRiseMonitoring</DisplayName>
    <Description>Additional monitoring for the process temperature</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6389</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6390</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6446</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6449</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1003</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6389" BrowseName="1:ErrorDetected" ParentNodeId="ns=1;i=5032" DataType="Boolean">
    <DisplayName>ErrorDetected</DisplayName>
    <Description>Result of the TemperatureRiseMonitoring</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5032</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6390" BrowseName="1:SetValueActive" ParentNodeId="ns=1;i=5032" DataType="Boolean" AccessLevel="3">
    <DisplayName>SetValueActive</DisplayName>
    <Description>On / Off for the TemperatureRiseMonitoring</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5032</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6446" BrowseName="1:SetValueTemperatureChange" ParentNodeId="ns=1;i=5032" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueTemperatureChange</DisplayName>
    <Description>Specification of the set value change</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6447</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6448</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5032</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6447" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6446" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6446</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6448" BrowseName="EURange" ParentNodeId="ns=1;i=6446" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6446</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6449" BrowseName="1:SupervisionTime" ParentNodeId="ns=1;i=5032" DataType="Duration" AccessLevel="3">
    <DisplayName>SupervisionTime</DisplayName>
    <Description>Specification of the time within the temperature must have changed</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5032</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6474" BrowseName="1:ThermocoupleType" ParentNodeId="ns=1;i=5019" DataType="UInt16" AccessLevel="3">
    <DisplayName>ThermocoupleType</DisplayName>
    <Description>Type of connected external temperature sensor </Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6475</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5019</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6476</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6475" BrowseName="EnumValues" ParentNodeId="ns=1;i=6474" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6474</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6476" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6474" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6474</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1007" BrowseName="1:MaintenanceInformationType">
    <DisplayName>MaintenanceInformationType</DisplayName>
    <Description>Information about the maintenance status of various parts of a hot runner device</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/12</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5005</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5006</Reference>
    </References>
  </UAObjectType>
  <UAObject NodeId="ns=1;i=5007" BrowseName="1:CoolingFan" ParentNodeId="ns=1;i=1007">
    <DisplayName>CoolingFan</DisplayName>
    <Description>Information about the maintenance status of the cooling fan</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6069</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1007</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6070</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6072</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7003</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6068</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6074</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6069" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5007" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6070" BrowseName="2:Interval" ParentNodeId="ns=1;i=5007" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <Description>Regular interval between two maintenances</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6363</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6071</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6363" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6070" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6070</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6071" BrowseName="EURange" ParentNodeId="ns=1;i=6070" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6070</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6072" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5007" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <Description>Interval before next maintenance is due</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6073</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6368" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6072" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6072</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6073" BrowseName="EURange" ParentNodeId="ns=1;i=6072" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6072</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7003" BrowseName="2:Reset" ParentNodeId="ns=1;i=5007" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the CurrentInterval to 0 and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6068" BrowseName="2:Status" ParentNodeId="ns=1;i=5007" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5007</Reference>
    </References>
    <Value>
      <uax:Int32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Int32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6074" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5007" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <Description>How long is the component running in total</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6370</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6075</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5007</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6370" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6074" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6074</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6075" BrowseName="EURange" ParentNodeId="ns=1;i=6074" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6074</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5005" BrowseName="1:Heating" ParentNodeId="ns=1;i=1007">
    <DisplayName>Heating</DisplayName>
    <Description>Information about the maintenance status of the heating</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6076</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1007</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6077</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6079</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7001</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6066</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6248</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6076" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5005" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5005</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6077" BrowseName="2:Interval" ParentNodeId="ns=1;i=5005" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <Description>Regular interval between two maintenances</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6250</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6078</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5005</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6250" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6077" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6077</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6078" BrowseName="EURange" ParentNodeId="ns=1;i=6077" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6077</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6079" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5005" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <Description>Interval before next maintenance is due</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6330</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6080</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5005</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6330" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6079" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6079</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6080" BrowseName="EURange" ParentNodeId="ns=1;i=6079" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6079</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7001" BrowseName="2:Reset" ParentNodeId="ns=1;i=5005" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the CurrentInterval to 0 and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5005</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6066" BrowseName="2:Status" ParentNodeId="ns=1;i=5005" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5005</Reference>
    </References>
    <Value>
      <uax:Int32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Int32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6248" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5005" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <Description>How long is the component running in total</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6331</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6249</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5005</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6331" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6248" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6248</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6249" BrowseName="EURange" ParentNodeId="ns=1;i=6248" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6248</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5006" BrowseName="1:SafetyTest" ParentNodeId="ns=1;i=1007">
    <DisplayName>SafetyTest</DisplayName>
    <Description>Information about the maintenance status of the safety test</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6332</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6333</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1053</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6335</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7002</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1007</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6067</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6337</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6332" BrowseName="2:AdditionalInformation" ParentNodeId="ns=1;i=5006" DataType="String">
    <DisplayName>AdditionalInformation</DisplayName>
    <Description>Additional information on the necessary maintenance. Can be also a link to another document.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5006</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6333" BrowseName="2:Interval" ParentNodeId="ns=1;i=5006" DataType="Double">
    <DisplayName>Interval</DisplayName>
    <Description>Regular interval between two maintenances</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6372</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6334</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6372" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6333" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6333</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6334" BrowseName="EURange" ParentNodeId="ns=1;i=6333" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6333</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6335" BrowseName="2:RemainingInterval" ParentNodeId="ns=1;i=5006" DataType="Double">
    <DisplayName>RemainingInterval</DisplayName>
    <Description>Interval before next maintenance is due</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6373</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6336</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6373" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6335" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6335</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6336" BrowseName="EURange" ParentNodeId="ns=1;i=6335" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6335</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7002" BrowseName="2:Reset" ParentNodeId="ns=1;i=5006" MethodDeclarationId="ns=2;i=7046">
    <DisplayName>Reset</DisplayName>
    <Description>This Method sets the CurrentInterval to 0 and Status to NOT_DUE_0</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6067" BrowseName="2:Status" ParentNodeId="ns=1;i=5006" DataType="MaintenanceStatusEnumeration">
    <DisplayName>Status</DisplayName>
    <Description>Maintenance status of the machine/device/component (represented by the parent element)</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5006</Reference>
    </References>
    <Value>
      <uax:Int32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Int32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6337" BrowseName="2:TotalOperation" ParentNodeId="ns=1;i=5006" DataType="Double">
    <DisplayName>TotalOperation</DisplayName>
    <Description>How long is the component running in total</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6374</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6338</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5006</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6374" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6337" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6337</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6338" BrowseName="EURange" ParentNodeId="ns=1;i=6337" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6337</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1011" BrowseName="1:HRDTemperatureType">
    <DisplayName>HRDTemperatureType</DisplayName>
    <Description>Used for setting and monitoring the temperatures in a HRD</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/14</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6653</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6132</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6118</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">ns=2;i=1057</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6253</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6255</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6164</Reference>
    </References>
  </UAObjectType>
  <UAVariable NodeId="ns=1;i=6653" BrowseName="1:ActiveSetValue" ParentNodeId="ns=1;i=1011" DataType="UInt16">
    <DisplayName>ActiveSetValue</DisplayName>
    <Description>Current active set temperature for the temperature zone </Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1011</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6654</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6655</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6654" BrowseName="EnumValues" ParentNodeId="ns=1;i=6653" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6653</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6655" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6653" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6653</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6132" BrowseName="1:BoostSetValue" ParentNodeId="ns=1;i=1011" DataType="Double" AccessLevel="3">
    <DisplayName>BoostSetValue</DisplayName>
    <Description>Set value for boost mode</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1011</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6436</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6200</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6436" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6132" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6132</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6200" BrowseName="EURange" ParentNodeId="ns=1;i=6132" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6132</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6118" BrowseName="1:BoostTime" ParentNodeId="ns=1;i=1011" DataType="Duration" AccessLevel="3">
    <DisplayName>BoostTime</DisplayName>
    <Description>Duration of the boost mode after which the set value which was active before boost is becoming active again</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1011</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6253" BrowseName="1:SecondSetValue" ParentNodeId="ns=1;i=1011" DataType="Double" AccessLevel="3">
    <DisplayName>SecondSetValue</DisplayName>
    <Description>Second set value for fast switch-over</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6256</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6254</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1011</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6256" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6253" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6253</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6254" BrowseName="EURange" ParentNodeId="ns=1;i=6253" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6253</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6255" BrowseName="1:StandbySetValue" ParentNodeId="ns=1;i=1011" DataType="Double" AccessLevel="3">
    <DisplayName>StandbySetValue</DisplayName>
    <Description>Set value for standby mode</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6437</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6279</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1011</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6437" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6255" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6255</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6279" BrowseName="EURange" ParentNodeId="ns=1;i=6255" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6255</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6164" BrowseName="1:TimeMethodPIDParameters" ParentNodeId="ns=1;i=1011" DataType="TimeMethodPIDParametersDataType" ValueRank="1" ArrayDimensions="0" AccessLevel="3">
    <DisplayName>TimeMethodPIDParameters</DisplayName>
    <Description>Setting of PID parameters with time method</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1011</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1009" BrowseName="1:OperationType">
    <DisplayName>OperationType</DisplayName>
    <Description>Contains components which are necessary to operate the HRD</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/9.1</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6215</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6217</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6214</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6216</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6506</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6213</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7006</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6494</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7007</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7019</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6649</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7031</Reference>
    </References>
  </UAObjectType>
  <UAVariable NodeId="ns=1;i=6215" BrowseName="1:ActiveErrors" ParentNodeId="ns=1;i=1009" DataType="ClassifiedActiveErrorDataType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>ActiveErrors</DisplayName>
    <Description>List of the active errors of the device</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=63</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6217" BrowseName="1:ActiveSetValues" ParentNodeId="ns=1;i=1009" DataType="UInt16" AccessLevel="3">
    <DisplayName>ActiveSetValues</DisplayName>
    <Description>Central selection of the used set temperature for the temperature zones </Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6393</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6394</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6393" BrowseName="EnumValues" ParentNodeId="ns=1;i=6217" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6217</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6394" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6217" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6217</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6214" BrowseName="1:DeviceMappingNumber" ParentNodeId="ns=1;i=1009" DataType="UInt32" AccessLevel="3">
    <DisplayName>DeviceMappingNumber</DisplayName>
    <Description>Unique identifier/address/number for devices of the same DeviceType within a local network</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6216" BrowseName="1:EnablePower" ParentNodeId="ns=1;i=1009" DataType="Boolean" AccessLevel="3">
    <DisplayName>EnablePower</DisplayName>
    <Description>Global power control switch for all zone controllers</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6506" BrowseName="1:EvenHeatUpMaxTemperatureDifference" ParentNodeId="ns=1;i=1009" DataType="Double" AccessLevel="3">
    <DisplayName>EvenHeatUpMaxTemperatureDifference</DisplayName>
    <Description>Definition of the maximum temperature difference of all zones during even heat-up </Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6647</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6507</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6647" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6506" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6506</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6507" BrowseName="EURange" ParentNodeId="ns=1;i=6506" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6506</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6213" BrowseName="1:HighestActiveAlarmSeverity" ParentNodeId="ns=1;i=1009" DataType="UInt16">
    <DisplayName>HighestActiveAlarmSeverity</DisplayName>
    <Description>Indication of the severity of the highest active alarm</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7006" BrowseName="1:IdentifyDevice" ParentNodeId="ns=1;i=1009">
    <DisplayName>IdentifyDevice</DisplayName>
    <Description>The peripheral device on which this method is called shows itself by e.g. activation of a LED.</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/9.2</Documentation>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6494" BrowseName="1:ReactionOnDisconnect" ParentNodeId="ns=1;i=1009" DataType="UInt16">
    <DisplayName>ReactionOnDisconnect</DisplayName>
    <Description>Selection of the set temperature for the temperature zones in case of a disconnection from the OPC UA client </Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6495</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6496</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6495" BrowseName="EnumValues" ParentNodeId="ns=1;i=6494" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6494</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6496" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6494" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6494</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7007" BrowseName="1:ResetAllErrors" ParentNodeId="ns=1;i=1009">
    <DisplayName>ResetAllErrors</DisplayName>
    <Description>Method to reset all errors of the device</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/9.5</Documentation>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
    </References>
  </UAMethod>
  <UAMethod NodeId="ns=1;i=7019" BrowseName="1:ResetErrorById" ParentNodeId="ns=1;i=1009">
    <DisplayName>ResetErrorById</DisplayName>
    <Description>Method to reset one error of the device</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/9.6</Documentation>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6378</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6378" BrowseName="InputArguments" ParentNodeId="ns=1;i=7019" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7019</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:ExtensionObject>
          <uax:TypeId>
            <uax:Identifier>i=297</uax:Identifier>
          </uax:TypeId>
          <uax:Body>
            <uax:Argument>
              <uax:Name>Id</uax:Name>
              <uax:DataType>
                <uax:Identifier>i=12</uax:Identifier>
              </uax:DataType>
              <uax:ValueRank>-1</uax:ValueRank>
              <uax:ArrayDimensions />
              <uax:Description />
            </uax:Argument>
          </uax:Body>
        </uax:ExtensionObject>
      </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6649" BrowseName="1:SessionNameForReactionOnDisconnect" ParentNodeId="ns=1;i=1009" DataType="String">
    <DisplayName>SessionNameForReactionOnDisconnect</DisplayName>
    <Description>Contains the sessionName of the connection with the client relevant for ReactionOnDisconnect</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1009</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7031" BrowseName="1:SetReactionOnDisconnect" ParentNodeId="ns=1;i=1009">
    <DisplayName>SetReactionOnDisconnect</DisplayName>
    <Description>Method to set ReactionOnDisconnect and SessionNameForReactionOnDisconnect</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/9.9</Documentation>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6651</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1009</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6651" BrowseName="InputArguments" ParentNodeId="ns=1;i=7031" DataType="Argument" ValueRank="1" ArrayDimensions="1">
    <DisplayName>InputArguments</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=7031</Reference>
    </References>
    <Value>
      <uax:ListOfExtensionObject xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:ExtensionObject>
          <uax:TypeId>
            <uax:Identifier>i=297</uax:Identifier>
          </uax:TypeId>
          <uax:Body>
            <uax:Argument>
              <uax:Name>ReactionOnDisconnect</uax:Name>
              <uax:DataType>
                <uax:Identifier>i=5</uax:Identifier>
              </uax:DataType>
              <uax:ValueRank>-1</uax:ValueRank>
              <uax:ArrayDimensions />
              <uax:Description />
            </uax:Argument>
          </uax:Body>
        </uax:ExtensionObject>
      </uax:ListOfExtensionObject>
    </Value>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1003" BrowseName="1:TemperatureRiseMonitoringType">
    <DisplayName>TemperatureRiseMonitoringType</DisplayName>
    <Description>At maximum controller output, the temperature value must change in a given time by a specified value, otherwise there is an error in the measuring circuit.</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/17.1</Documentation>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6003</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6005</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6004</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
    </References>
  </UAObjectType>
  <UAVariable NodeId="ns=1;i=6003" BrowseName="1:ErrorDetected" ParentNodeId="ns=1;i=1003" DataType="Boolean">
    <DisplayName>ErrorDetected</DisplayName>
    <Description>Result of the TemperatureRiseMonitoring</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1003</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6002" BrowseName="1:SetValueActive" ParentNodeId="ns=1;i=1003" DataType="Boolean" AccessLevel="3">
    <DisplayName>SetValueActive</DisplayName>
    <Description>On / Off for the TemperatureRiseMonitoring</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1003</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6005" BrowseName="1:SetValueTemperatureChange" ParentNodeId="ns=1;i=1003" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueTemperatureChange</DisplayName>
    <Description>Specification of the set value change</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6007</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6006</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6007" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6005" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6005</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6006" BrowseName="EURange" ParentNodeId="ns=1;i=6005" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6005</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6004" BrowseName="1:SupervisionTime" ParentNodeId="ns=1;i=1003" DataType="Duration" AccessLevel="3">
    <DisplayName>SupervisionTime</DisplayName>
    <Description>Specification of the time within the temperature must have changed</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1008" BrowseName="1:ZonesType">
    <DisplayName>ZonesType</DisplayName>
    <Description>Container for the zones</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/10</Documentation>
    <References>
      <Reference ReferenceType="GeneratesEvent">i=2133</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6136</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
    </References>
  </UAObjectType>
  <UAVariable NodeId="ns=1;i=6136" BrowseName="NodeVersion" ParentNodeId="ns=1;i=1008" DataType="String">
    <DisplayName>NodeVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1008</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
      </uax:String>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5009" BrowseName="1:Zone_&lt;Nr&gt;" SymbolicName="Zone__Nr_" ParentNodeId="ns=1;i=1008">
    <DisplayName>Zone_&lt;Nr&gt;</DisplayName>
    <Description>A HRD zone</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6382</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5011</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6055</Reference>
      <Reference ReferenceType="HasModellingRule">i=11510</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6144</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5013</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6150</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1008</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1006</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6382" BrowseName="1:CommunicationProtocolType" ParentNodeId="ns=1;i=5009" DataType="UInt16" AccessLevel="3">
    <DisplayName>CommunicationProtocolType</DisplayName>
    <Description>Used communication protocol between the sensor and the control system of the HRD</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6386</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6387</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6386" BrowseName="EnumValues" ParentNodeId="ns=1;i=6382" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6382</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6387" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6382" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6382</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5010" BrowseName="1:Controller" ParentNodeId="ns=1;i=5009">
    <DisplayName>Controller</DisplayName>
    <Description>Setting and monitoring of the controller</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6154</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6139</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6140</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6137</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6156</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6158</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6160</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6161</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6141</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6162</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6316</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6165</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6167</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6154" BrowseName="1:ActualOutput" ParentNodeId="ns=1;i=5010" DataType="Double">
    <DisplayName>ActualOutput</DisplayName>
    <Description>Indicates the currently active output in percent</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6312</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6155</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6312" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6154" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6154</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6155" BrowseName="EURange" ParentNodeId="ns=1;i=6154" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6154</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6139" BrowseName="1:ActualType" ParentNodeId="ns=1;i=5010" DataType="ControllerTypeEnumeration">
    <DisplayName>ActualType</DisplayName>
    <Description>Actual value for the controller type used by the zone</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Int32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Int32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6140" BrowseName="1:ActualValueActive" ParentNodeId="ns=1;i=5010" DataType="Boolean">
    <DisplayName>ActualValueActive</DisplayName>
    <Description>Indicates the current status of the controller</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6137" BrowseName="1:AutomaticReferenceZoneSelection" ParentNodeId="ns=1;i=5010" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticReferenceZoneSelection</DisplayName>
    <Description>If true, the HRD selects automatically the reference zone.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6156" BrowseName="1:AverageControllerOutput" ParentNodeId="ns=1;i=5010" DataType="Double">
    <DisplayName>AverageControllerOutput</DisplayName>
    <Description>Indicates the average output which can be used when a sensor is broken</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6313</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6157</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6313" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6156" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6156</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6157" BrowseName="EURange" ParentNodeId="ns=1;i=6156" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6156</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5042" BrowseName="1:LoadCurrent" ParentNodeId="ns=1;i=5010">
    <DisplayName>LoadCurrent</DisplayName>
    <Description>Information about the load current in Ampere</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6537</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6578</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6581</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6582</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6585</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6588</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6591</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6594</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7029</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6597</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6600</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6603</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6719</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6606</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6609</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6537" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5042" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6577</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6538</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6577" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6537" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6537</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6538" BrowseName="EURange" ParentNodeId="ns=1;i=6537" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6537</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6578" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5042" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6579</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6580</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6579" BrowseName="EnumValues" ParentNodeId="ns=1;i=6578" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6578</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6580" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6578" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6578</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6581" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5042" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6582" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5042" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6583</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6584</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6583" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6582" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6582</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6584" BrowseName="EURange" ParentNodeId="ns=1;i=6582" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6582</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6585" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5042" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6586</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6587</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6586" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6585" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6585</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6587" BrowseName="EURange" ParentNodeId="ns=1;i=6585" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6585</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6588" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5042" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6589</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6590</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6589" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6588" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6588</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6590" BrowseName="EURange" ParentNodeId="ns=1;i=6588" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6588</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6591" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5042" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6592</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6593</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6592" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6591" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6591</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6593" BrowseName="EURange" ParentNodeId="ns=1;i=6591" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6591</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6594" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5042" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6595</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6596</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6595" BrowseName="EnumValues" ParentNodeId="ns=1;i=6594" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6594</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6596" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6594" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6594</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7029" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5042" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6597" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5042" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6598</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6599</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6598" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6597" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6597</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6599" BrowseName="EURange" ParentNodeId="ns=1;i=6597" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6597</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6600" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5042" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6601</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6602</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6601" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6600" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6600</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6602" BrowseName="EURange" ParentNodeId="ns=1;i=6600" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6600</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6603" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5042" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6604</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6605</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6604" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6603" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6603</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6605" BrowseName="EURange" ParentNodeId="ns=1;i=6603" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6603</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6719" BrowseName="2:Status" ParentNodeId="ns=1;i=5042" DataType="UInt16">
    <DisplayName>Status</DisplayName>
    <Description>Information if the ActualValue is within the tolerances or has passed a tolerance or min/max value</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6720</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6721</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6720" BrowseName="EnumValues" ParentNodeId="ns=1;i=6719" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6719</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6721" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6719" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6719</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6606" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5042" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6607</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6608</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6607" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6606" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6606</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6608" BrowseName="EURange" ParentNodeId="ns=1;i=6606" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6606</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6609" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5042" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6610</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6611</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5042</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6610" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6609" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6609</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6611" BrowseName="EURange" ParentNodeId="ns=1;i=6609" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6609</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5046" BrowseName="1:LoadPower" ParentNodeId="ns=1;i=5010">
    <DisplayName>LoadPower</DisplayName>
    <Description>Information about the load power in Watt</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6727</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6727" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5046" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5046</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6728</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6728" BrowseName="EURange" ParentNodeId="ns=1;i=6727" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6727</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6158" BrowseName="1:LowerOutput" ParentNodeId="ns=1;i=5010" DataType="Double" AccessLevel="3">
    <DisplayName>LowerOutput</DisplayName>
    <Description>Limitation of the minimum output in closed-loop control in %</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6310</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6159</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6310" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6158" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6158</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6159" BrowseName="EURange" ParentNodeId="ns=1;i=6158" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6158</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6160" BrowseName="1:OutputTime" ParentNodeId="ns=1;i=5010" DataType="Duration" AccessLevel="3">
    <DisplayName>OutputTime</DisplayName>
    <Description>Time basis for operating the actuator</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6161" BrowseName="1:ReferenceZone" ParentNodeId="ns=1;i=5010" DataType="UInt32" AccessLevel="3">
    <DisplayName>ReferenceZone</DisplayName>
    <Description>If zones are to operate parallel to a control zone, the reference relation can be realised with this parameter.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6141" BrowseName="1:SetValueActive" ParentNodeId="ns=1;i=5010" DataType="Boolean" AccessLevel="3">
    <DisplayName>SetValueActive</DisplayName>
    <Description>A control zone is switched on and off with this parameter.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5010</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6162" BrowseName="1:SetValueManualOutput" ParentNodeId="ns=1;i=5010" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueManualOutput</DisplayName>
    <Description>Manually given output in percent if SetValueType = MANUAL is selected</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6311</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6163</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6311" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6162" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6162</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6163" BrowseName="EURange" ParentNodeId="ns=1;i=6162" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6162</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6316" BrowseName="1:SetValueType" ParentNodeId="ns=1;i=5010" DataType="UInt16" AccessLevel="3">
    <DisplayName>SetValueType</DisplayName>
    <Description>Set value for the controller type used by the zone</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6317</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6318</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6317" BrowseName="EnumValues" ParentNodeId="ns=1;i=6316" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6316</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6318" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6316" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6316</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6165" BrowseName="1:UpperOutput" ParentNodeId="ns=1;i=5010" DataType="Double" AccessLevel="3">
    <DisplayName>UpperOutput</DisplayName>
    <Description>Limitation of the maximum output in closed-loop control in %</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6309</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6166</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6309" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6165" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6165</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6166" BrowseName="EURange" ParentNodeId="ns=1;i=6165" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6165</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6167" BrowseName="1:UpperSetValueCascade" ParentNodeId="ns=1;i=5010" DataType="Double" AccessLevel="3">
    <DisplayName>UpperSetValueCascade</DisplayName>
    <Description>If the two controllers are cascaded, the master defines to which nominal temperature value the slave is to control to. With this parameter, the upper limit for the slave is defined.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6315</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6168</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5010</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6315" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6167" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6167</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6168" BrowseName="EURange" ParentNodeId="ns=1;i=6167" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6167</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5011" BrowseName="1:HeatUp" ParentNodeId="ns=1;i=5009">
    <DisplayName>HeatUp</DisplayName>
    <Description>Setting for heat up procedure</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6169</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1004</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6170</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6384</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6385</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6171</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6173</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6169" BrowseName="1:EvenHeatUpEnabled" ParentNodeId="ns=1;i=5011" DataType="Boolean" AccessLevel="3">
    <DisplayName>EvenHeatUpEnabled</DisplayName>
    <Description>Enables even heat-up process until nominal SetValue of Temperature of ZoneType is reached</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5011</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6170" BrowseName="1:ManualOutputLimitActive" ParentNodeId="ns=1;i=5011" DataType="Boolean" AccessLevel="3">
    <DisplayName>ManualOutputLimitActive</DisplayName>
    <Description>Activates heat-up process with pre-defined SetValueManualOutputLimit until SetValueTemperature is reached</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5011</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6384" BrowseName="1:RelayHeatingGroup" ParentNodeId="ns=1;i=5011" DataType="Byte" AccessLevel="3">
    <DisplayName>RelayHeatingGroup</DisplayName>
    <Description>Number of the heating group for relay heating</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5011</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6385" BrowseName="1:RelayHeatingTime" ParentNodeId="ns=1;i=5011" DataType="Duration" AccessLevel="3">
    <DisplayName>RelayHeatingTime</DisplayName>
    <Description>Time for relay heating of the zone. When RelayHeatingTime of all zones of a heating group have expired, the next group starts heating.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5011</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6171" BrowseName="1:SetValueManualOutputLimit" ParentNodeId="ns=1;i=5011" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueManualOutputLimit</DisplayName>
    <Description>This pre-defined maximum output (in percent) is valid until the SetValueTemperature is reached.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6209</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6172</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5011</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6209" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6171" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6171</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6172" BrowseName="EURange" ParentNodeId="ns=1;i=6171" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6171</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6173" BrowseName="1:SetValueTemperature" ParentNodeId="ns=1;i=5011" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueTemperature</DisplayName>
    <Description>If ManualOutputLimitActive is set, SetValueManualOutputLimit is active until this nominal temperature value is reached.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6210</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6174</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5011</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6210" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6173" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6173</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6174" BrowseName="EURange" ParentNodeId="ns=1;i=6173" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6173</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6055" BrowseName="1:HighestActiveAlarmSeverity" ParentNodeId="ns=1;i=5009" DataType="UInt16">
    <DisplayName>HighestActiveAlarmSeverity</DisplayName>
    <Description>Indicates the severity of the highest active alarm related to the current zone</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6144" BrowseName="1:Name" ParentNodeId="ns=1;i=5009" DataType="String" AccessLevel="3">
    <DisplayName>Name</DisplayName>
    <Description>A user given name of the zone</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
      </uax:String>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5008" BrowseName="1:Temperature" ParentNodeId="ns=1;i=5009">
    <DisplayName>Temperature</DisplayName>
    <Description>Setting and monitoring of the temperature</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6659</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6104</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6206</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6257</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6454</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6502</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1011</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6258</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6260</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6262</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6266</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6268</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7025</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6263</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6271</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6273</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6275</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6456</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6707</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6503</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6277</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6280</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6659" BrowseName="1:ActiveSetValue" ParentNodeId="ns=1;i=5008" DataType="UInt16">
    <DisplayName>ActiveSetValue</DisplayName>
    <Description>Current active set temperature for the temperature zone </Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6660</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6661</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6660" BrowseName="EnumValues" ParentNodeId="ns=1;i=6659" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6659</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6661" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6659" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6659</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6104" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5008" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6126</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6105</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6126" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6104" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6104</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6105" BrowseName="EURange" ParentNodeId="ns=1;i=6104" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6104</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6206" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5008" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6235</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6236</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6235" BrowseName="EnumValues" ParentNodeId="ns=1;i=6206" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6206</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6236" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6206" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6206</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6257" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5008" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6454" BrowseName="1:BoostSetValue" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>BoostSetValue</DisplayName>
    <Description>Set value for boost mode</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6464</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6455</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6464" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6454" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6454</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6455" BrowseName="EURange" ParentNodeId="ns=1;i=6454" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6454</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6502" BrowseName="1:BoostTime" ParentNodeId="ns=1;i=5008" DataType="Duration" AccessLevel="3">
    <DisplayName>BoostTime</DisplayName>
    <Description>Duration of the boost mode after which the set value which was active before boost is becoming active again</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5021" BrowseName="2:ClosedLoopControl" ParentNodeId="ns=1;i=5008">
    <DisplayName>ClosedLoopControl</DisplayName>
    <Description>With this type the client can do settings for the closed loop control on the device for a parameter</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6128</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6129</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7004</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7005</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6130</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6128" BrowseName="2:AutomaticControllerMode" ParentNodeId="ns=1;i=5021" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticControllerMode</DisplayName>
    <Description>Determination if PID Parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6129" BrowseName="2:AutoTuningActive" ParentNodeId="ns=1;i=5021" DataType="Boolean">
    <DisplayName>AutoTuningActive</DisplayName>
    <Description>Informs if the automatic tuning is currently active</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7004" BrowseName="2:AutoTuningOff" ParentNodeId="ns=1;i=5021" MethodDeclarationId="ns=2;i=7048">
    <DisplayName>AutoTuningOff</DisplayName>
    <Description>Stops an already active self-optimisation process (no control parameters are changed)</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAMethod NodeId="ns=1;i=7005" BrowseName="2:AutoTuningOn" ParentNodeId="ns=1;i=5021" MethodDeclarationId="ns=2;i=7047">
    <DisplayName>AutoTuningOn</DisplayName>
    <Description>Starts the self-optimisation of the controller</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6130" BrowseName="2:PIDParameters" ParentNodeId="ns=1;i=5021" DataType="PIDParametersDataType" ValueRank="1" ArrayDimensions="0" AccessLevel="3">
    <DisplayName>PIDParameters</DisplayName>
    <Description>PID Parameters as array if several input signals (sensors) are used for the control</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5021</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6258" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6417</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6259</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6417" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6258" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6258</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6259" BrowseName="EURange" ParentNodeId="ns=1;i=6258" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6258</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6260" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6418</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6261</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6418" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6260" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6260</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6261" BrowseName="EURange" ParentNodeId="ns=1;i=6260" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6260</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6262" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6419</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6265</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6419" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6262" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6262</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6265" BrowseName="EURange" ParentNodeId="ns=1;i=6262" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6262</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6266" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6420</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6267</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6420" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6266" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6266</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6267" BrowseName="EURange" ParentNodeId="ns=1;i=6266" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6266</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6268" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5008" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6269</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6270</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6269" BrowseName="EnumValues" ParentNodeId="ns=1;i=6268" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6268</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6270" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6268" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6268</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7025" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5008" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6263" BrowseName="1:SecondSetValue" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>SecondSetValue</DisplayName>
    <Description>Second set value for fast switch-over</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6410</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6264</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6410" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6263" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6263</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6264" BrowseName="EURange" ParentNodeId="ns=1;i=6263" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6263</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6271" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6421</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6272</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6421" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6271" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6271</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6272" BrowseName="EURange" ParentNodeId="ns=1;i=6271" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6271</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6273" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6422</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6274</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6422" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6273" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6273</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6274" BrowseName="EURange" ParentNodeId="ns=1;i=6273" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6273</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6275" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6424</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6276</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6424" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6275" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6275</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6276" BrowseName="EURange" ParentNodeId="ns=1;i=6275" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6275</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6456" BrowseName="1:StandbySetValue" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>StandbySetValue</DisplayName>
    <Description>Set value for standby mode</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6465</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6457</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6465" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6456" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6456</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6457" BrowseName="EURange" ParentNodeId="ns=1;i=6456" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6456</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6707" BrowseName="2:Status" ParentNodeId="ns=1;i=5008" DataType="UInt16">
    <DisplayName>Status</DisplayName>
    <Description>Information if the ActualValue is within the tolerances or has passed a tolerance or min/max value</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6708</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6709</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6708" BrowseName="EnumValues" ParentNodeId="ns=1;i=6707" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6707</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6709" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6707" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6707</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6503" BrowseName="1:TimeMethodPIDParameters" ParentNodeId="ns=1;i=5008" DataType="TimeMethodPIDParametersDataType" ValueRank="1" ArrayDimensions="0" AccessLevel="3">
    <DisplayName>TimeMethodPIDParameters</DisplayName>
    <Description>Setting of PID parameters with time method</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5008</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6277" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6425</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6278</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6425" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6277" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6277</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6278" BrowseName="EURange" ParentNodeId="ns=1;i=6277" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6277</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6280" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5008" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6426</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6281</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5008</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6426" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6280" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6280</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6281" BrowseName="EURange" ParentNodeId="ns=1;i=6280" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6280</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5013" BrowseName="1:TemperatureRiseMonitoring" ParentNodeId="ns=1;i=5009">
    <DisplayName>TemperatureRiseMonitoring</DisplayName>
    <Description>Additional monitoring for the process temperature</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6148</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6149</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6203</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6205</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1003</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6148" BrowseName="1:ErrorDetected" ParentNodeId="ns=1;i=5013" DataType="Boolean">
    <DisplayName>ErrorDetected</DisplayName>
    <Description>Result of the TemperatureRiseMonitoring</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5013</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6149" BrowseName="1:SetValueActive" ParentNodeId="ns=1;i=5013" DataType="Boolean" AccessLevel="3">
    <DisplayName>SetValueActive</DisplayName>
    <Description>On / Off for the TemperatureRiseMonitoring</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5013</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6203" BrowseName="1:SetValueTemperatureChange" ParentNodeId="ns=1;i=5013" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueTemperatureChange</DisplayName>
    <Description>Specification of the set value change</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6212</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6204</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5013</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6212" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6203" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6203</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6204" BrowseName="EURange" ParentNodeId="ns=1;i=6203" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6203</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6205" BrowseName="1:SupervisionTime" ParentNodeId="ns=1;i=5013" DataType="Duration" AccessLevel="3">
    <DisplayName>SupervisionTime</DisplayName>
    <Description>Specification of the time within the temperature must have changed</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5013</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6150" BrowseName="1:ThermocoupleType" ParentNodeId="ns=1;i=5009" DataType="UInt16" AccessLevel="3">
    <DisplayName>ThermocoupleType</DisplayName>
    <Description>Type of connected external temperature sensor </Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6391</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5009</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6392</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6391" BrowseName="EnumValues" ParentNodeId="ns=1;i=6150" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6150</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6392" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6150" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6150</Reference>
    </References>
  </UAVariable>
  <UAObjectType NodeId="ns=1;i=1006" BrowseName="1:ZoneType">
    <DisplayName>ZoneType</DisplayName>
    <Description>Represents all functionalities of a heating zone, such as temperature monitoring, control, heatup</Description>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/13.1</Documentation>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6380</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6052</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6051</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5004</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6053</Reference>
      <Reference ReferenceType="HasSubtype" IsForward="false">i=58</Reference>
    </References>
  </UAObjectType>
  <UAVariable NodeId="ns=1;i=6380" BrowseName="1:CommunicationProtocolType" ParentNodeId="ns=1;i=1006" DataType="UInt16" AccessLevel="3">
    <DisplayName>CommunicationProtocolType</DisplayName>
    <Description>Used communication protocol between the sensor and the control system of the HRD</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1006</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6381</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6383</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6381" BrowseName="EnumValues" ParentNodeId="ns=1;i=6380" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6380</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6383" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6380" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6380</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5002" BrowseName="1:Controller" ParentNodeId="ns=1;i=1006">
    <DisplayName>Controller</DisplayName>
    <Description>Setting and monitoring of the controller</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6083</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6059</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6060</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6085</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1006</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1005</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5045</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6087</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6089</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6090</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6061</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6091</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6306</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6094</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6096</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6083" BrowseName="1:ActualOutput" ParentNodeId="ns=1;i=5002" DataType="Double">
    <DisplayName>ActualOutput</DisplayName>
    <Description>Indicates the currently active output in percent</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6232</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6084</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6232" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6083" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6083</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6084" BrowseName="EURange" ParentNodeId="ns=1;i=6083" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6083</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6059" BrowseName="1:ActualType" ParentNodeId="ns=1;i=5002" DataType="ControllerTypeEnumeration">
    <DisplayName>ActualType</DisplayName>
    <Description>Actual value for the controller type used by the zone</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Int32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Int32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6060" BrowseName="1:ActualValueActive" ParentNodeId="ns=1;i=5002" DataType="Boolean">
    <DisplayName>ActualValueActive</DisplayName>
    <Description>Indicates the current status of the controller</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6056" BrowseName="1:AutomaticReferenceZoneSelection" ParentNodeId="ns=1;i=5002" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticReferenceZoneSelection</DisplayName>
    <Description>If true, the HRD selects automatically the reference zone.</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6085" BrowseName="1:AverageControllerOutput" ParentNodeId="ns=1;i=5002" DataType="Double">
    <DisplayName>AverageControllerOutput</DisplayName>
    <Description>Indicates the average output which can be used when a sensor is broken</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6233</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6086</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6233" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6085" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6085</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6086" BrowseName="EURange" ParentNodeId="ns=1;i=6085" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6085</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5041" BrowseName="1:LoadCurrent" ParentNodeId="ns=1;i=5002">
    <DisplayName>LoadCurrent</DisplayName>
    <Description>Information about the load current in Ampere</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6535</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6543</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6546</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6547</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6550</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6553</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6556</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6559</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7028</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6562</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6565</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6568</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6716</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6571</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6574</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6535" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5041" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6542</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6536</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6542" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6535" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6535</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6536" BrowseName="EURange" ParentNodeId="ns=1;i=6535" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6535</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6543" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5041" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6544</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6545</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6544" BrowseName="EnumValues" ParentNodeId="ns=1;i=6543" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6543</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6545" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6543" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6543</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6546" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5041" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6547" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5041" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6548</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6549</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6548" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6547" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6547</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6549" BrowseName="EURange" ParentNodeId="ns=1;i=6547" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6547</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6550" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5041" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6551</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6552</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6551" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6550" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6550</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6552" BrowseName="EURange" ParentNodeId="ns=1;i=6550" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6550</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6553" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5041" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6554</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6555</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6554" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6553" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6553</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6555" BrowseName="EURange" ParentNodeId="ns=1;i=6553" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6553</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6556" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5041" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6557</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6558</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6557" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6556" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6556</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6558" BrowseName="EURange" ParentNodeId="ns=1;i=6556" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6556</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6559" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5041" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6560</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6561</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6560" BrowseName="EnumValues" ParentNodeId="ns=1;i=6559" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6559</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6561" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6559" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6559</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7028" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5041" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6562" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5041" DataType="Double">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6563</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6564</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6563" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6562" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6562</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6564" BrowseName="EURange" ParentNodeId="ns=1;i=6562" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6562</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6565" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5041" DataType="Double">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6566</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6567</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6566" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6565" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6565</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6567" BrowseName="EURange" ParentNodeId="ns=1;i=6565" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6565</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6568" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5041" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6569</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6570</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6569" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6568" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6568</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6570" BrowseName="EURange" ParentNodeId="ns=1;i=6568" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6568</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6716" BrowseName="2:Status" ParentNodeId="ns=1;i=5041" DataType="UInt16">
    <DisplayName>Status</DisplayName>
    <Description>Information if the ActualValue is within the tolerances or has passed a tolerance or min/max value</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6717</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6718</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6717" BrowseName="EnumValues" ParentNodeId="ns=1;i=6716" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6716</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6718" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6716" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6716</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6571" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5041" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6572</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6573</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6572" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6571" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6571</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6573" BrowseName="EURange" ParentNodeId="ns=1;i=6571" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6571</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6574" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5041" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6575</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6576</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5041</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6575" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6574" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6574</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6576" BrowseName="EURange" ParentNodeId="ns=1;i=6574" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6574</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5045" BrowseName="1:LoadPower" ParentNodeId="ns=1;i=5002">
    <DisplayName>LoadPower</DisplayName>
    <Description>Information about the load power in Watt</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6725</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1056</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6725" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5045" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5045</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6726</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6726" BrowseName="EURange" ParentNodeId="ns=1;i=6725" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6725</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6087" BrowseName="1:LowerOutput" ParentNodeId="ns=1;i=5002" DataType="Double" AccessLevel="3">
    <DisplayName>LowerOutput</DisplayName>
    <Description>Limitation of the minimum output in closed-loop control in %</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6142</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6088</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6142" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6087" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6087</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6088" BrowseName="EURange" ParentNodeId="ns=1;i=6087" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6087</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6089" BrowseName="1:OutputTime" ParentNodeId="ns=1;i=5002" DataType="Duration" AccessLevel="3">
    <DisplayName>OutputTime</DisplayName>
    <Description>Time basis for operating the actuator</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6090" BrowseName="1:ReferenceZone" ParentNodeId="ns=1;i=5002" DataType="UInt32" AccessLevel="3">
    <DisplayName>ReferenceZone</DisplayName>
    <Description>If zones are to operate parallel to a control zone, the reference relation can be realised with this parameter.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5002</Reference>
    </References>
    <Value>
      <uax:UInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6061" BrowseName="1:SetValueActive" ParentNodeId="ns=1;i=5002" DataType="Boolean" AccessLevel="3">
    <DisplayName>SetValueActive</DisplayName>
    <Description>A control zone is switched on and off with this parameter.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5002</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6091" BrowseName="1:SetValueManualOutput" ParentNodeId="ns=1;i=5002" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueManualOutput</DisplayName>
    <Description>Manually given output in percent if SetValueType = MANUAL is selected</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6143</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6092</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6143" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6091" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6091</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6092" BrowseName="EURange" ParentNodeId="ns=1;i=6091" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6091</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6306" BrowseName="1:SetValueType" ParentNodeId="ns=1;i=5002" DataType="UInt16" AccessLevel="3">
    <DisplayName>SetValueType</DisplayName>
    <Description>Set value for the controller type used by the zone</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6307</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6308</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6307" BrowseName="EnumValues" ParentNodeId="ns=1;i=6306" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6306</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6308" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6306" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6306</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6094" BrowseName="1:UpperOutput" ParentNodeId="ns=1;i=5002" DataType="Double" AccessLevel="3">
    <DisplayName>UpperOutput</DisplayName>
    <Description>Limitation of the maximum output in closed-loop control in %</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6063</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6095</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6063" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6094" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6094</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6095" BrowseName="EURange" ParentNodeId="ns=1;i=6094" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6094</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6096" BrowseName="1:UpperSetValueCascade" ParentNodeId="ns=1;i=5002" DataType="Double" AccessLevel="3">
    <DisplayName>UpperSetValueCascade</DisplayName>
    <Description>If the two controllers are cascaded, the master defines to which nominal temperature value the slave is to control to. With this parameter, the upper limit for the slave is defined.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6305</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6097</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5002</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6305" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6096" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6096</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6097" BrowseName="EURange" ParentNodeId="ns=1;i=6096" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6096</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5003" BrowseName="1:HeatUp" ParentNodeId="ns=1;i=1006">
    <DisplayName>HeatUp</DisplayName>
    <Description>Setting for heat up procedure</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6098</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1006</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1004</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6099</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6145</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6234</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6100</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6102</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6098" BrowseName="1:EvenHeatUpEnabled" ParentNodeId="ns=1;i=5003" DataType="Boolean" AccessLevel="3">
    <DisplayName>EvenHeatUpEnabled</DisplayName>
    <Description>Enables even heat-up process until nominal SetValue of Temperature of ZoneType is reached</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6099" BrowseName="1:ManualOutputLimitActive" ParentNodeId="ns=1;i=5003" DataType="Boolean" AccessLevel="3">
    <DisplayName>ManualOutputLimitActive</DisplayName>
    <Description>Activates heat-up process with pre-defined SetValueManualOutputLimit until SetValueTemperature is reached</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5003</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6145" BrowseName="1:RelayHeatingGroup" ParentNodeId="ns=1;i=5003" DataType="Byte" AccessLevel="3">
    <DisplayName>RelayHeatingGroup</DisplayName>
    <Description>Number of the heating group for relay heating</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5003</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6234" BrowseName="1:RelayHeatingTime" ParentNodeId="ns=1;i=5003" DataType="Duration" AccessLevel="3">
    <DisplayName>RelayHeatingTime</DisplayName>
    <Description>Time for relay heating of the zone. When RelayHeatingTime of all zones of a heating group have expired, the next group starts heating.</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5003</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6100" BrowseName="1:SetValueManualOutputLimit" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueManualOutputLimit</DisplayName>
    <Description>This pre-defined maximum output (in percent) is valid until the SetValueTemperature is reached.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6207</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6101</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6207" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6100" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6100</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6101" BrowseName="EURange" ParentNodeId="ns=1;i=6100" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6100</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6102" BrowseName="1:SetValueTemperature" ParentNodeId="ns=1;i=5003" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueTemperature</DisplayName>
    <Description>If ManualOutputLimitActive is set, SetValueManualOutputLimit is active until this nominal temperature value is reached.</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6208</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6103</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5003</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6208" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6102" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6102</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6103" BrowseName="EURange" ParentNodeId="ns=1;i=6102" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6102</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6052" BrowseName="1:HighestActiveAlarmSeverity" ParentNodeId="ns=1;i=1006" DataType="UInt16">
    <DisplayName>HighestActiveAlarmSeverity</DisplayName>
    <Description>Indicates the severity of the highest active alarm related to the current zone</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1006</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6051" BrowseName="1:Name" ParentNodeId="ns=1;i=1006" DataType="String" AccessLevel="3">
    <DisplayName>Name</DisplayName>
    <Description>A user given name of the zone</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=1006</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
      </uax:String>
    </Value>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5001" BrowseName="1:Temperature" ParentNodeId="ns=1;i=1006">
    <DisplayName>Temperature</DisplayName>
    <Description>Setting and monitoring of the temperature</Description>
    <References>
      <Reference ReferenceType="HasComponent">ns=1;i=6656</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6057</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6175</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6178</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6450</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6470</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=5014</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1011</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6179</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6181</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6183</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6187</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6189</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7024</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6184</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6192</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6194</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6196</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6452</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6704</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1006</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6501</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6198</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6201</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6656" BrowseName="1:ActiveSetValue" ParentNodeId="ns=1;i=5001" DataType="UInt16">
    <DisplayName>ActiveSetValue</DisplayName>
    <Description>Current active set temperature for the temperature zone </Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6657</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6658</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6657" BrowseName="EnumValues" ParentNodeId="ns=1;i=6656" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6656</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6658" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6656" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6656</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6057" BrowseName="2:ActualValue" ParentNodeId="ns=1;i=5001" DataType="Double">
    <DisplayName>ActualValue</DisplayName>
    <Description>Actual value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6125</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6058</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6125" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6057" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6057</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6058" BrowseName="EURange" ParentNodeId="ns=1;i=6057" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6057</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6175" BrowseName="2:AlarmSuppression" ParentNodeId="ns=1;i=5001" DataType="UInt16" AccessLevel="3">
    <DisplayName>AlarmSuppression</DisplayName>
    <Description>The start-up alarm suppression deactivates alarms of a monitored parameter during start up or a setpoint jump</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6176</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6177</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6176" BrowseName="EnumValues" ParentNodeId="ns=1;i=6175" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6175</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6177" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6175" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6175</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6178" BrowseName="2:AutomaticMonitoring" ParentNodeId="ns=1;i=5001" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticMonitoring</DisplayName>
    <Description>Determination if monitoring tolerance parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6450" BrowseName="1:BoostSetValue" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>BoostSetValue</DisplayName>
    <Description>Set value for boost mode</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6462</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6451</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6462" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6450" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6450</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6451" BrowseName="EURange" ParentNodeId="ns=1;i=6450" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6450</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6470" BrowseName="1:BoostTime" ParentNodeId="ns=1;i=5001" DataType="Duration" AccessLevel="3">
    <DisplayName>BoostTime</DisplayName>
    <Description>Duration of the boost mode after which the set value which was active before boost is becoming active again</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5014" BrowseName="2:ClosedLoopControl" ParentNodeId="ns=1;i=5001">
    <DisplayName>ClosedLoopControl</DisplayName>
    <Description>With this type the client can do settings for the closed loop control on the device for a parameter</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6398</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6399</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7021</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=7022</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=2;i=1054</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6400</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6398" BrowseName="2:AutomaticControllerMode" ParentNodeId="ns=1;i=5014" DataType="Boolean" AccessLevel="3">
    <DisplayName>AutomaticControllerMode</DisplayName>
    <Description>Determination if PID Parameters are determined by auto-tuning itself (TRUE) or can be manually adjusted (FALSE)</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5014</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6399" BrowseName="2:AutoTuningActive" ParentNodeId="ns=1;i=5014" DataType="Boolean">
    <DisplayName>AutoTuningActive</DisplayName>
    <Description>Informs if the automatic tuning is currently active</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5014</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7021" BrowseName="2:AutoTuningOff" ParentNodeId="ns=1;i=5014" MethodDeclarationId="ns=2;i=7048">
    <DisplayName>AutoTuningOff</DisplayName>
    <Description>Stops an already active self-optimisation process (no control parameters are changed)</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5014</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAMethod NodeId="ns=1;i=7022" BrowseName="2:AutoTuningOn" ParentNodeId="ns=1;i=5014" MethodDeclarationId="ns=2;i=7047">
    <DisplayName>AutoTuningOn</DisplayName>
    <Description>Starts the self-optimisation of the controller</Description>
    <References>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5014</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6400" BrowseName="2:PIDParameters" ParentNodeId="ns=1;i=5014" DataType="PIDParametersDataType" ValueRank="1" ArrayDimensions="0" AccessLevel="3">
    <DisplayName>PIDParameters</DisplayName>
    <Description>PID Parameters as array if several input signals (sensors) are used for the control</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5014</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6179" BrowseName="2:LowerTolerance" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance</DisplayName>
    <Description>Lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6407</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6180</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6407" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6179" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6179</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6180" BrowseName="EURange" ParentNodeId="ns=1;i=6179" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6179</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6181" BrowseName="2:LowerTolerance2" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>LowerTolerance2</DisplayName>
    <Description>Second lower relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6408</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6182</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6408" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6181" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6181</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6182" BrowseName="EURange" ParentNodeId="ns=1;i=6181" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6181</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6183" BrowseName="2:MaxValue" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>MaxValue</DisplayName>
    <Description>Maximum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6409</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6186</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6409" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6183" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6183</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6186" BrowseName="EURange" ParentNodeId="ns=1;i=6183" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6183</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6187" BrowseName="2:MinValue" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>MinValue</DisplayName>
    <Description>Minimum absolute value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6411</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6188</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6411" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6187" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6187</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6188" BrowseName="EURange" ParentNodeId="ns=1;i=6187" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6187</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6189" BrowseName="2:MonitoringSensitivity" ParentNodeId="ns=1;i=5001" DataType="UInt16" AccessLevel="3">
    <DisplayName>MonitoringSensitivity</DisplayName>
    <Description>Defines how closely the tolerances are set during the automatic limit setting</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6190</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6191</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6190" BrowseName="EnumValues" ParentNodeId="ns=1;i=6189" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6189</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6191" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6189" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6189</Reference>
    </References>
  </UAVariable>
  <UAMethod NodeId="ns=1;i=7024" BrowseName="2:ResetMonitoring" ParentNodeId="ns=1;i=5001" MethodDeclarationId="ns=2;i=7053">
    <DisplayName>ResetMonitoring</DisplayName>
    <Description>With this method the tolerance values are set according to the actual value and the set monitoring sensitivity</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
  </UAMethod>
  <UAVariable NodeId="ns=1;i=6184" BrowseName="1:SecondSetValue" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>SecondSetValue</DisplayName>
    <Description>Second set value for fast switch-over</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6397</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6185</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6397" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6184" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6184</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6185" BrowseName="EURange" ParentNodeId="ns=1;i=6184" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6184</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6192" BrowseName="2:SetRampDown" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampDown</DisplayName>
    <Description>Indication if SetValue that is lower than the actual value shall be reached as fast as possible (SetRampDown = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6412</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6193</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6412" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6192" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6192</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6193" BrowseName="EURange" ParentNodeId="ns=1;i=6192" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6192</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6194" BrowseName="2:SetRampUp" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>SetRampUp</DisplayName>
    <Description>Indication if a SetValue that is higher than the actual value shall be reached as fast as possible (SetRampUp = 0) or within a given value change per time</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6413</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6195</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6413" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6194" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6194</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6195" BrowseName="EURange" ParentNodeId="ns=1;i=6194" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6194</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6196" BrowseName="2:SetValue" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>SetValue</DisplayName>
    <Description>Set/nominal/target value of the monitored parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6414</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6197</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6414" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6196" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6196</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6197" BrowseName="EURange" ParentNodeId="ns=1;i=6196" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6196</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6452" BrowseName="1:StandbySetValue" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>StandbySetValue</DisplayName>
    <Description>Set value for standby mode</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6463</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6453</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6463" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6452" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6452</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6453" BrowseName="EURange" ParentNodeId="ns=1;i=6452" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6452</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6704" BrowseName="2:Status" ParentNodeId="ns=1;i=5001" DataType="UInt16">
    <DisplayName>Status</DisplayName>
    <Description>Information if the ActualValue is within the tolerances or has passed a tolerance or min/max value</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6705</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6706</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6705" BrowseName="EnumValues" ParentNodeId="ns=1;i=6704" DataType="EnumValueType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6704</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6706" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6704" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6704</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6501" BrowseName="1:TimeMethodPIDParameters" ParentNodeId="ns=1;i=5001" DataType="TimeMethodPIDParametersDataType" ValueRank="1" ArrayDimensions="0" AccessLevel="3">
    <DisplayName>TimeMethodPIDParameters</DisplayName>
    <Description>Setting of PID parameters with time method</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5001</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6198" BrowseName="2:UpperTolerance" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance</DisplayName>
    <Description>Upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6415</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6199</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6415" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6198" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6198</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6199" BrowseName="EURange" ParentNodeId="ns=1;i=6198" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6198</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6201" BrowseName="2:UpperTolerance2" ParentNodeId="ns=1;i=5001" DataType="Double" AccessLevel="3">
    <DisplayName>UpperTolerance2</DisplayName>
    <Description>Second upper relative tolerance value of the process parameter</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6416</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6202</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5001</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6416" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6201" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6201</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6202" BrowseName="EURange" ParentNodeId="ns=1;i=6201" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6201</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5004" BrowseName="1:TemperatureRiseMonitoring" ParentNodeId="ns=1;i=1006">
    <DisplayName>TemperatureRiseMonitoring</DisplayName>
    <Description>Additional monitoring for the process temperature</Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6064</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6065</Reference>
      <Reference ReferenceType="HasComponent">ns=1;i=6133</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6135</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1006</Reference>
      <Reference ReferenceType="HasTypeDefinition">ns=1;i=1003</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6064" BrowseName="1:ErrorDetected" ParentNodeId="ns=1;i=5004" DataType="Boolean">
    <DisplayName>ErrorDetected</DisplayName>
    <Description>Result of the TemperatureRiseMonitoring</Description>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5004</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6065" BrowseName="1:SetValueActive" ParentNodeId="ns=1;i=5004" DataType="Boolean" AccessLevel="3">
    <DisplayName>SetValueActive</DisplayName>
    <Description>On / Off for the TemperatureRiseMonitoring</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5004</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6133" BrowseName="1:SetValueTemperatureChange" ParentNodeId="ns=1;i=5004" DataType="Double" AccessLevel="3">
    <DisplayName>SetValueTemperatureChange</DisplayName>
    <Description>Specification of the set value change</Description>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=2368</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6211</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6134</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=5004</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6211" BrowseName="EngineeringUnits" ParentNodeId="ns=1;i=6133" DataType="EUInformation">
    <DisplayName>EngineeringUnits</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6133</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6134" BrowseName="EURange" ParentNodeId="ns=1;i=6133" DataType="Range">
    <DisplayName>EURange</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6133</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6135" BrowseName="1:SupervisionTime" ParentNodeId="ns=1;i=5004" DataType="Duration" AccessLevel="3">
    <DisplayName>SupervisionTime</DisplayName>
    <Description>Specification of the time within the temperature must have changed</Description>
    <References>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5004</Reference>
    </References>
    <Value>
      <uax:Double xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:Double>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6053" BrowseName="1:ThermocoupleType" ParentNodeId="ns=1;i=1006" DataType="UInt16" AccessLevel="3">
    <DisplayName>ThermocoupleType</DisplayName>
    <Description>Type of connected external temperature sensor </Description>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6054</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11238</Reference>
      <Reference ReferenceType="HasModellingRule">i=80</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">ns=1;i=1006</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6151</Reference>
    </References>
    <Value>
      <uax:UInt16 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">0</uax:UInt16>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6054" BrowseName="EnumValues" ParentNodeId="ns=1;i=6053" DataType="EnumValueType" ValueRank="1">
    <DisplayName>EnumValues</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6053</Reference>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6151" BrowseName="ValueAsText" ParentNodeId="ns=1;i=6053" DataType="LocalizedText">
    <DisplayName>ValueAsText</DisplayName>
    <References>
      <Reference ReferenceType="HasModellingRule">i=78</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=6053</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5033" BrowseName="1:http://opcfoundation.org/UA/PlasticsRubber/HotRunner/" SymbolicName="http___opcfoundation_org_UA_PlasticsRubber_HotRunner_">
    <DisplayName>http://opcfoundation.org/UA/PlasticsRubber/HotRunner/</DisplayName>
    <Documentation>https://reference.opcfoundation.org/v104/PlasticsRubber/HotRunner/v100/docs/20.1</Documentation>
    <References>
      <Reference ReferenceType="HasProperty">ns=1;i=6477</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=11616</Reference>
      <Reference ReferenceType="HasComponent" IsForward="false">i=11715</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6478</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6479</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6480</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6481</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6482</Reference>
      <Reference ReferenceType="HasProperty">ns=1;i=6483</Reference>
    </References>
  </UAObject>
  <UAVariable NodeId="ns=1;i=6477" BrowseName="IsNamespaceSubset" ParentNodeId="ns=1;i=5033" DataType="Boolean">
    <DisplayName>IsNamespaceSubset</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5033</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:Boolean xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">false</uax:Boolean>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6478" BrowseName="NamespacePublicationDate" ParentNodeId="ns=1;i=5033" DataType="DateTime">
    <DisplayName>NamespacePublicationDate</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5033</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:DateTime xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">2021-05-10T12:00:00Z</uax:DateTime>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6479" BrowseName="NamespaceUri" ParentNodeId="ns=1;i=5033" DataType="String">
    <DisplayName>NamespaceUri</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5033</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">http://opcfoundation.org/UA/PlasticsRubber/HotRunner/</uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6480" BrowseName="NamespaceVersion" ParentNodeId="ns=1;i=5033" DataType="String">
    <DisplayName>NamespaceVersion</DisplayName>
    <References>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5033</Reference>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
    </References>
    <Value>
      <uax:String xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">1.00</uax:String>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6481" BrowseName="StaticNodeIdTypes" ParentNodeId="ns=1;i=5033" DataType="IdType" ValueRank="1" ArrayDimensions="0">
    <DisplayName>StaticNodeIdTypes</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5033</Reference>
    </References>
    <Value>
      <uax:ListOfInt32 xmlns:uax="http://opcfoundation.org/UA/2008/02/Types.xsd">
        <uax:Int32>0</uax:Int32>
      </uax:ListOfInt32>
    </Value>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6482" BrowseName="StaticNumericNodeIdRange" ParentNodeId="ns=1;i=5033" DataType="NumericRange" ValueRank="1" ArrayDimensions="0">
    <DisplayName>StaticNumericNodeIdRange</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5033</Reference>
    </References>
  </UAVariable>
  <UAVariable NodeId="ns=1;i=6483" BrowseName="StaticStringNodeIdPattern" ParentNodeId="ns=1;i=5033" DataType="String">
    <DisplayName>StaticStringNodeIdPattern</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=68</Reference>
      <Reference ReferenceType="HasProperty" IsForward="false">ns=1;i=5033</Reference>
    </References>
  </UAVariable>
  <UAObject NodeId="ns=1;i=5028" BrowseName="Default Binary" SymbolicName="DefaultBinary">
    <DisplayName>Default Binary</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=76</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5029" BrowseName="Default XML" SymbolicName="DefaultXml">
    <DisplayName>Default XML</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=76</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5030" BrowseName="Default JSON" SymbolicName="DefaultJson">
    <DisplayName>Default JSON</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=76</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5037" BrowseName="Default Binary" SymbolicName="DefaultBinary">
    <DisplayName>Default Binary</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=76</Reference>
      <Reference ReferenceType="HasEncoding" IsForward="false">ns=1;i=3005</Reference>
      <Reference ReferenceType="HasDescription">ns=1;i=6040</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5038" BrowseName="Default XML" SymbolicName="DefaultXml">
    <DisplayName>Default XML</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=76</Reference>
      <Reference ReferenceType="HasEncoding" IsForward="false">ns=1;i=3005</Reference>
      <Reference ReferenceType="HasDescription">ns=1;i=6093</Reference>
    </References>
  </UAObject>
  <UAObject NodeId="ns=1;i=5039" BrowseName="Default JSON" SymbolicName="DefaultJson">
    <DisplayName>Default JSON</DisplayName>
    <References>
      <Reference ReferenceType="HasTypeDefinition">i=76</Reference>
      <Reference ReferenceType="HasEncoding" IsForward="false">ns=1;i=3005</Reference>
    </References>
  </UAObject>
</UANodeSet>