IntegrityRejectedMaterialLogType

The IntegrityRejectedMaterialLogType Event is triggered when a presented material is rejected at an object of type MaterialLoadingPointType because of a failed material integrity check.
The representation of the IntegrityRejectedMaterialLogType ObjectType in the address space is shown in the following table:
Name | Attribute |
---|---|
NodeId | ns=1;i=1039 |
NamespaceUri | http://opcfoundation.org/UA/TMC/ |
BrowseName | IntegrityRejectedMaterialLogType |
NodeClass | ObjectType |
IsAbstract | False |
SubtypeOf | LogbookEventType |
The references from the IntegrityRejectedMaterialLogType ObjectType Node are shown in the following table:
Reference | NodeClass | BrowseName | DataType | TypeDefinition | ModellingRule |
---|---|---|---|---|---|
HasComponent | Variable | RejectedLot | Double | MaterialLotType | Mandatory |