6 Information Models ToC Previous Next

6.2 Datatype Definition ToC Previous Next

6.2.3 RequestSPDUDataType ToC Previous Next index

Table 19 – RequestSPDUDataType Structure

Name Type Description
RequestSPDUDataType structure  
   InSafetyConsumerID UInt32 See corresponding method argument in Table 8.
   InMonitoringNumber UInt32 See corresponding method argument in Table 8.
   InFlags InFlagsType See corresponding method argument in Table 8.

NOTE: The Prefix “In” should be interpreted from the SafetyProvider’s point of view and is used in a consistent manner to the parameters of the method ReadSafetyData (see 6.1.3).

Attributes Value        
BrowseName RequestSPDUDataType        
IsAbstract FALSE        
References NodeClass BrowseName DataType TypeDefinition ModellingRule
Subtype of Structure defined in OPC 10000-5.          
Conformance Units          
SafetyPDUs          

Previous Next