FryingPanParameterType provides information about the state of the device, the set values and the current actual values.

The FryingPanParameterType is formally defined in Table 18.

Table 18 — FryingPanParameterType definition

Attribute

Value

BrowseName

FryingPanParameterType

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

ModellingRule AccessLevel

Subtype of KitchenDeviceParameterType

HasComponent

Variable

ProgramMode

FryingPanModeEnumeration

BaseDataVariableType

M, R

HasComponent

Variable

CookingLevel

Int32

BaseDataVariableType

M, R

HasComponent

Variable

SetTemperature

Float

AnalogItemType

M, R

HasComponent

Variable

ActualTemperature

Float

AnalogItemType

M, R

HasComponent

Variable

SetProcessTime

Int32

AnalogItemType

M, R

HasComponent

Variable

TimeRemaining

Int32

AnalogItemType

M, R

HasComponent

Variable

SetCoreTemperature

Float

AnalogItemType

M, R

HasComponent

Variable

ActualCoreTemperature

Float

AnalogItemType

M, R

HasComponent

Variable

SignalMode

SignalModeEnumeration

BaseDataVariableType

M, R

HasComponent

Variable

ActualPressurePan

Float

AnalogItemType

O, R

HasComponent

Variable

IsLidLocked

Boolean

BaseDataVariableType

O, R

This variable describes the state of the device, e.g. heating up or frying.

The data type for the FryingPanModeEnumeration is defined in section 7.4.1.

This variable describes the cooking level with which heating up is to take place.

The value is used only in the Cook and CookSlow ProgramMode.

This variable contains the set temperature to which heating up is to take place. With pressure cooking the set pressure is calculated on the basis of the set temperature.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes the currently measured temperature.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes the set process time in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

This variable describes the remaining process time in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

This variable describes the set core temperature.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes the currently measured core temperature.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable describes the state of the signal output. In addition to the on and off states, the "Signal was acknowledged" state is also saved.

The data type for the SignalModeEnumeration is defined in 7.4.2.

This variable describes the currently measured pressure in the pan.

The EngineeringUnit property of the AnalogItemType has the value mbar. The value for the EURange property is device-specific.

This variable describes whether the lid is locked.