Table 18 – RequestSPDUDataType Structure
Name |
Type |
Description |
RequestSPDUDataType |
structure |
|
InSafetyConsumerID |
UInt32 |
See corresponding method argument in Table 7. |
InMonitoringNumber |
UInt32 |
See corresponding method argument in Table 7. |
InFlags |
InFlagsType |
See corresponding method argument in Table 7. |
NOTE The Prefix “In” should be interpreted from the SafetyProvider’s point of view and is used in a consistent manner to the parameters of the method ReadSafetyData (see 6.2.2.3).
The representation in the AddressSpace of the RequestSPDUDataType DataType is defined in Table 19.
Table 19 – RequestSPDUDataType definition
Attributes |
Value |
||||
BrowseName |
RequestSPDUDataType |
||||
IsAbstract |
False |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
ModellingRule |
Subtype of Structure defined in OPC 10000-5. |
|||||
Conformance Units |
|||||
SafetyPDUs |