OPC 30141: PROFIenergy


Released 1.00

2021-03-11

This document is subject to the license terms described here.

The general OPC Foundation specification license agreement also applies and can be found here.

This document is a copy of the original which can be found here.


1 Scope 2 Normative references 3 Terms, abbreviated terms and conventions 3.1 Overview 3.2 OPC UA for PROFIenergy terms 3.2.1 PE Energy Management 3.2.2 Standby Management 3.2.3 Standby Management Entity 3.2.4 Energy Saving Mode 3.2.5 Energy Measurement 3.2.6 Metering Point 3.2.7 Sleep Mode WOL 3.3 Abbreviated terms 3.4 Conventions used in this document 3.4.1 Conventions for Node descriptions 3.4.1.1 Node definitions 3.4.1.2 Additional References 3.4.1.3 Additional sub-components 3.4.2 NodeIds and BrowseNames 3.4.2.1 NodeIds 3.4.2.2 BrowseNames 3.4.3 Common Attributes 3.4.3.1 General 3.4.3.2 Objects 3.4.3.3 Variables 3.4.3.4 VariableTypes 3.4.3.5 Methods 4 General information to PE Energy Management and OPC UA 4.1 Introduction to PE Energy Management 4.1.1 General 4.1.2 Standby Management 4.1.3 Energy Measurement 4.1.4 Sleep Mode WOL 4.2 Introduction to OPC Unified Architecture 4.2.1 What is OPC UA? 4.2.2 Basics of OPC UA 4.2.3 Information modelling in OPC UA 4.2.3.1 Concepts 4.2.3.2 Namespaces 4.2.3.3 Companion Specifications 5 Use cases 6 PE Energy Management Information Model 7 PROFIenergy Service Access Point Information Model 8 OPC UA ObjectTypes 8.1 Standby Management 8.1.1 EnergyStandbyManagementType 8.1.1.1 StartPause Method 8.1.1.2 SwitchToEnergySavingMode Method 8.1.1.3 EndPause Method 8.1.2 EnergySavingModesContainerType 8.1.3 EnergySavingModeStatusType 8.1.4 EnergySavingModeType 8.2 Energy Measurement 8.2.1 Overview 8.2.2 EnergyMeasurementType 8.2.3 Interfaces for EnergyProfiles 8.2.3.1 IEnergyProfileE0Type 8.2.3.2 IEnergyProfileE1Type 8.2.3.3 IEnergyProfileE2Type 8.2.3.4 IEnergyProfileE3Type 8.2.3.5 IEnergyProfileD0Type 8.3 Sleep Mode WOL Functionality 8.3.1 EnergyDevicePowerOffType 8.3.1.1 SwitchOffWOL Method 8.4 PeServiceAccessPointType 9 OPC UA VariableTypes 9.1 MeasurementValueType 10 OPC UA DataTypes 10.1 Structures 10.1.1 StandbyModeTransitionDataType 10.1.2 EnergyStateInformationDataType 10.1.3 PeVersionDataType 10.1.4 AcPeDataType 10.1.5 AcPpDataType 10.2 Enumerations 10.2.1 PeClassEnumeration 10.2.2 PeSubclassEnumeration 10.2.3 AccuracyDomainEnumeration 10.2.4 AccuracyClassEnumeration 11 OPC UA ReferenceTypes 11.1 Represents Reference Type 11.2 HasEnergyStandbyManagement Reference Type 11.3 HasEnergyMeasurement Reference Type 11.4 HasEnergyPowerOff Reference Type 12 Profiles and Conformance Units 12.1 Conformance Units 12.2 Profiles 12.2.1 Profile list 12.2.2 Server Facets 12.2.2.1 Overview 12.2.2.2 PNEM Energy Management Server Profile 12.2.2.3 PNEM Energy Management Control Server Profile 12.2.2.4 PNEM PROFINET Energy Management Server Profile 12.2.2.5 PNEM PROFINET Energy Management Control Server Profile 12.2.2.6 PNEM Energy Controller Server Facet 12.2.3 Client Facets 13 Namespaces 13.1 Namespace Metadata 13.2 Handling of OPC UA Namespaces Annex A (normative) OPC UA for PROFIenergy Namespace and mappings A.1 Namespace and identifiers for OPC UA for PROFIenergy Information Model Annex B (Informative)Relationship to PROFIenergy Concepts B.1 PE Entity Annex C (Informative)PROFIenergy Common Application Profile C.1 What is PROFIenergy? C.2 Services of PROFIenergy C.3 PE Object Model C.4 PE State Model C.5 Mapping of Measurement values C.5.1 Energy Measurements